Some errors in ads

Source: Internet
Author: User

Encountered in the *.O file can not find the situation, and usually is the beginning of the normal link, and after a number of re-link is not found (even if just add an insignificant hollow in the code), the new project will be the current. C and. h files are added intact, then link does not appear in this situation, so it is estimated that the ads itself link problems do not know what you say is the same problem. 2. AXD appears. Ses could not find an error: The project directory can not be Chinese, modified to English, recompile, if not yet, Axd-options-configure target-double-click armul-ok-ok,file-load image-find the appropriate. axf file. Can. This method repeats every time. Radical Cure: By comparing C:\Documents and Settings\****\ Default-1-2-0-0.ses debugging before and after the change, found that the problem is here, the file is an initial configuration file, after debugging the target file, the file with the debug target file path and other redundant information, so, Axd is not recognized, naturally appear ' C \ Documents and
Settings\****\default-1-2-0-0.ses ' could not being loaded hint. As long as the configuration is completed, the properties of the file should be read-only, then it will not be modified during debugging, and there will be no error. Note The file's boot path (to find the path of the STARTUP.S), Default-1-2-0-0.ses repeatedly deleted a few times carefully compared to understand.
3. ADS1.2 cannot find os_cpu_a.o on link: After copying the project to the hard disk, you must remove the read-only properties of all the project folders and files. If the item is moved to a different folder, before recompiling, select the menu project--Remove object code ... and press "all Tagerts" in the Pop-up dialog box to delete the original compiled generated *.O file to compile successfully.

ADS1.2 compile, there is no target file found in directory (*.O)
Compile a copy to a project on the hard disk, the following Fatal error Message:error: (Fatal) l6002:could not open file F:\ working backup
\20061204\HC_DTMF3\DVS-ATM_DATA\RELINFLASH\OBJECTCODE\STARTUO.O.
"F:\ Work Backup" This directory I did not, "Hc_dtmf3\dvs-atm_data" This directory is the source code directory, but I was extracted to the desktop, why the "F:\ work Backup", but also compile?
Analysis reason: caused by previous compilation on other computers. Workaround: After copying the ads project to the hard drive, you must remove the read-only properties of all the project folders and files. If the item is moved to a different folder, before recompiling, select the menu project--Remove object code ... and press "all Tagerts" in the Pop-up dialog box to delete the original compiled generated *.O file to compile successfully.
1 Patttern * (RW) only matches removed unused sections.
In the case of this warning I have encountered two, one is the definition of the global variable when the spelling error in the reference, the change to solve. Another situation does not know what the program has been wrong, this time can be in
Edit/debuginxxxsettings., ARM linker options under the Remove unused section under the removal of a few segments of remove can be, the current warning is said RW, so put read Write a tick to remove it, the other two things the same. :) 2 Sometimes there are cases where a file cannot be opened
Project/remove object code, if not yet, quit, project do not put in the Chinese directory, change a directory, and then Project/remove Object code, the problem is OK. 3 Data termination occurs during program execution
In the Ucos_ii environment, run Zlg GUI, take data termination, and later found that the GUI task stack is too small, originally 64, changed to 1024, problem solving
4: Just learning to use ads software, in the process of using code WARRIOR for ARM, found some *. The MCP file cannot be opened by double-clicking. It turns out that the software is not very supportive of the Chinese path, but we can still open it by dragging and dropping, and by code WARRIOR for ARM's menu file--open--both ways. 5. If you install ads under WIN7 X64, you will have
Warning:L6301W:Could not find file C:\Program Files. Error:L6218:Undefined symbol ....
It seems that the library is not found. The question is on the brackets in program Files (x86). Ads is a 1997 product and is not good for localization support. This will only occur under the WIN7 X64 system, x32 does not have a directory of program Files (x86) and will not


There is such a problem.
So ads all access to the path, cannot have text or special symbols.
Workaround: You can install ads in the C root directory. For example: C:\ARM\ADSv1_2. And you need to start as an administrator when you run ads.

Some errors in ads

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.