Use the Modbus protocol times Java.net.SocketException:recvfrom Failed:econnreset solution in Android programs

Source: Internet
Author: User

Recently in the development of basic Modbus Protocol of the Android PLC control program, C # version of the program does not have any problems, moved to Java under a variety of problems, which is more troubling is Java.net.SocketException:recvfrom failed: Econnreset error.

My solution was to switch off the socket every time I sent a piece of data to the PLC, but it was too extreme.

After analysis of the packet size I set to 256, when writing 1 register value, Modbus server directly error, switch off the socket connection, the size of the packet sent to the actual size to solve the problem.

(C # version of the program is also set to 256, no this phenomenon)

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.