IntroductionThis article mainly introduces the installation and deployment of the Linux operating system of the Enterprise Blade machine.first, create RAID
Following this interface, always press F10 to enter the system boot
Go to the server comes with the boot program, the default choice of Simplified Chinese, keyboard type by default
Click OS Deployment to start installing the system
Here you can choose to configure RAID first or
Dell Server disk status Foreign how to clean up after use 1. Restart the server and enter the RAID card BIOS setup interface.2. Enter PD mgmt To view the status of the failed disk (foreign: foreign, Online: normal, missing: Disk not found, failed: failed)3, such as the disk status of foreign, into the VD Mgmt Select Contrllor 0, press F2, select Foreign, select c
Dell-R720 server (Centos6.5) Dual Nic binding
System Environment:
Operating System: Centos 6.5x64
Server: Dell R720
Procedure:
1. Download the NIC Driver from the DELL website
Bcom_LAN_14.1.0_LinuxR5S10_DKMS_A01.tar.gz (NIC Driver)
Dkms-2.2.0.3-1.noarch.rpm (dkms)
2. Instal
Impi not detailed description of what to do, can be in the article in the annex below the detailed description, have a very good patience of friends can carefully read.Let's take a look at how the Impi function is set on the Dell server, taking R720 as an example, and the other models are similar:You can see the following settings in the Idrac network settings650) this.width=650; "src=" http://s3.51cto.com/
array card itself, the BIOS of the array card. (typically used to reinstall a system or without an operating system, create a container (Adaptec array card)/logical drive (Ami/lsi array card).Use the Configuration tool software provided by the third party to achieve the management of the card. such as Dell Array Manager. (These software is used for the operating system already installed on the server)Third
On the afternoon of March 30, 2015, colleagues came out from the computer room and told me that the server disk is bright yellow light.I went to the computer room and saw the problematic server. The Dell r720 front panel flashes:Fault detected on drive 0 in disk drive Bay 1. The Chinese meaning is approximately: in Drive Bay 1, Disk 0 detects a failure.Disk 0 LED
The site environment has two units of 06 annual output of the Dell R710 Server, RHEL5.4 operating system, an application server, an Oracle database server, hardware configuration, operating system, independent array card.A computer room power outage, air conditioning does not work, the engine room
Bootmgr is missing solution appears in the system. Special attention should be paid to the problem of installing the system on dell server, bootmgrmissingThe bootmgr is missing solution appears in the system. Special attention should be paid to the installation of the system on dell servers.
Welcome to http://blog.csdn.net/aaa123524457
Reprinted please indicate t
The Dell System E-support Tool (DSET) collects information about the hardware, storage, and operating system of the Dell Poweredgetm server.This information is counted as a system configuration report that can be used to view configuration information and troubleshootingAs a step in the troubleshooting, Dell technical Support may ask you to provide dsetWith Dset
Centos 7 mounts a raid 10 hard drive to the Dell R730 Server
The company purchased a new Dell R730 server with two SAS hard disks and four SATA hard disks respectively. SAS hard disks constitute RAID 1 and SATA constitute raid 10. Install Centos 7 on the server and set RAID
Virtualization of DELL server account opening and hyper-threading EnabledR410 R7101. Press the F11 button in the upper-right corner of the boot screen, and EnterBiosBootingManager will be displayed after you press it. In a short time, you will enter BIOS settings.2. Enter the BIOS option, select "SystemSetup", and press Enter.3. Select "ProcessSettings" and press Enter.4. Click the tab, select "Virtualizati
Here are the steps to import a foreign hard drive into an array card, please do so when you are sure the data is backed up, and only provide references .Today, the Dell 720 system fails to boot up the monitor to see if there is a problem with the raid;1. Start the boot by pressing "ctrl+r" to enter the raid settings.2. enter PD Mgmt to view the status of the failed disk (foreign: foreign, Online: normal, missing: Disk not found, failed: failed)3. If t
Server: dell™poweredge™860
System: Windows 2003 R2
Problem: Install the 2003R2 version, the BIOS can identify 4G memory, after installing the system, can only recognize 256MB memory.
"How to solve the problem"
Enter BIOS as shown:
Setting the original OS Install Mode = "on" to "off" solves the problem that the
DELL
On the Dell R410 server, Debian 6 is issued by datahunter at, 28/11/2011 -.
Downstream PDF text
Update Time: 2/2/2012
Installing Debian on Dell R410 has a problem,
No Nic bnx2 driver (Broadcom NetXtremeII)
The reason is that it is non-free ....
There are two solutions:
1. The simplest
After the complete security of Debian, the lower-end firmware-bnx2.deb to n
In the Nehalem-EX era, DELL released three machines, a previously tested Blade Server M910 and two rack-mounted servers R810 and R910. They are all four-way machines, but both M910 and R810 are models that can be used for four or two-way configuration BKJIA. Recommended reading: 4-way Nehalem-EX Dell M910 server evalua
In linux, view the RAID status of the dell server-Linux Enterprise Application-Linux server application information. The following is a detailed description. View the status of the dell hard disk in linux
1. First install srvadmin on the dell installation disc
2. Run the c
HpInstall the HP Tools:yum install hpssacli1 View controller status RAID card model, etc.HPSSACLI Ctrl all Show status2 view HDD type, size RAID level, status, etc.HPSSACLI Ctrl all show config3 View details for all controllersHPSSACLI Ctrl all Show Detail4 Viewing the Controller information above slot 2HPSSACLI Ctrl slot=2 Show Detail5 View the drive information under a controller (slot 2), equivalent to 2HPSSACLI CTRL slot=2 PD all show status6 Viewing the drive status under a controller (slot
.jpg "title=" Store 7.jpg "alt=" Wkiol1d_aiicykhcaadktvn3eug556.jpg "/>Ok! The expansion of the virtual host disk is complete. View the results. The disk space is getting bigger. The whole process of the original disk is a data storage. Directly after the online expansion. No data loss found. If the data is very important. Please back up beforehand.650) this.width=650; "src=" Http://s2.51cto.com/wyfs02/M00/83/E9/wKioL1d_aW6D_12KAAKIFUbljHw091.jpg "title=" Chunchu7.jpg "alt=" Wkiol1d_aw6d_12kaaki
Prerequisite: Connect the server-specific Idrac network interface to the network1. Log on to the server (that is, the server being monitored).2. Installing Client ToolsYum install OpenIPMI openipmi-devel openipmi-libs ipmitool ipmiutil ipmiutil-devel ipmiutil-static-ySystemctl Start IPMISystemctl Enable IPMISystemctl Status IPMI3. Check if the relevant module is
A few days ago, the company purchased a new server, DELL R720. After installing and installing CentOS 5.6, it found that only lo exists and there is no eth * Nic, after several queries, rhel5.x or centos 5 was installed for newer machines such as r620 and r720. x system, without its NIC driver, so we need to install it ourselvesNIC Driver, http://zh-cn.broadcom.com/support/ethernet_nic/downloaddrivers.phpWe
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.