integrated
The ST and SC connectors are commonly used in general networks. The ST head is inserted and rotated for half a week. The disadvantage is that it is easy to break. The SC connector is directly inserted and inserted, which is easy to use. The disadvantage is that the FC connector is usually used in telecom networks, there is a nut screwed to the adapter, the advantage is reliable, dust protection, the disadvantage is that the installation time is a little longer. The MTRJ patch cord co
From the data, we can see that the current market demand for gigabit backbone switches is not high. Here we mainly analyze the functions and practical applications of mainstream Gigabit backbone switches. In the six Ethernet switches we tested, the EDIMAXES-5800R and LeaPComm6004 switches are not manageable switches, The Accton es00008 and the Thinker3800 switch of the Creative Company are all network tube switches, 3Com4900 is a layer-3 and layer-4 switch, and digital China D-Link DGS3308TG is
Currently, the mainstream Gigabit backbone switches have high forwarding capabilities and smaller sizes. They are suitable for common users. Among the six Ethernet switches we have tested, EDIMAX ES-5800R and LeaPComm6004 switch is not manageable switch, Accton es00008 and creative company Thinker3800 switch are network tube type switch, 3Com 4900 is support Layer 3 and Layer 4 switch, digital China D-Link DGS3308TG is a layer-3 switch.
Performance first
Among the six products, there are both fu
Of the six Ethernet switches we tested, the Edimax es-5800r and LeaPComm6004 switches are not managed switches, Accton ES4508, and the Thinker3800 switches of the creators are all network-management switches, 3Com 4900 is to support the three-layer and four-layer switch, Shenzhou digital D-link DGS3308TG is a three-tier switch.
Performance is the brunt
The 6 products include all copper ports, all fiber ports, and gbic ports, of which 3Com 4900 has 1
The Fiber jumper (also known as the optical fiber connector), which is the optical connector to access the optical module, also has many kinds, and can not be mutually used. The SFP module is connected to the LC fibre optic connector, while the GBIC is connected to the SC fiber optic connector. The following is a detailed description of several commonly used optical fiber connectors in Network engineering: ①FC Type fiber jumper: The external streng
transmission bandwidth.
Both of these methods support stacked redundant connections, respectively. When using daisy-chained connections, redundant connections are made by connecting the top switch to the bottom switch with a stacked cable. When point-to-point connection is used, it is accomplished by using the 2nd 3508 switch.
3, a Gigabit Catalyst3550 XL using a stacked card stack, another gigabit can be connected to gigabit switches or gigabit servers?
OK.
Need to use the 1000BASE-
a maximum of 2Gbps Full-duplex transmission bandwidth. Both of these methods support stacked redundant connections, respectively. When using daisy-chained connections, redundant connections are made by connecting the top switch to the bottom switch with a stacked cable. When point-to-point connection is used, it is accomplished by using the 2nd 3508 switch.
3. A Gigabit Catalyst3500 XL uses a stack of cards to make a stack, and can another gigabit port connect a gigabit switch or gigabit serve
at 1000 Mbps. nonegotiate can only use 1000BASE-SX,-LX, and-zx gbic on these GBIC. Copy running-config startup-config // Save settings (8)ConfigurationEtherChannel Several Ethernet ports are bound to an independent Logical Link. For example, 4006Vswitch, You can bind up to eight compatible ports with the same speed on any module of 4006. Each Ethernet channel ha
VLAN 1. Use the no switchport trunk native vlan port configuration command to return to the default status.
6) configure a group of Ports
4006 # configure terminal
4006 (config) # interface range fastethernet2/1-5
4006 (config-if-range) # no shutdown
// Note: a space must be added between the port numbers. For example, interface range fastethernet 2/1-5 is valid, while interface range fastethernet 2/1-5 is invalid.
The following example shows how to configure groups
for cascade between backbone switches. Note that all optical fiber ports are not stacked and can only be used for Cascade.
Optical jumper crossover
Each vswitch has two fiber-optic ports, one for one request. Of course, the optical fiber jumper must also be two; otherwise, communication between ports fails. When a vswitch is cascade through an optical fiber port, both ends of the optical fiber jumper must be sent and received. When one end is "received", the other end is "sent ".
Similarly, whe
line instead of a direct line.
Optical Switch Port Cascade
Because Fiber ports are still very expensive, fiber cables are mainly used for connection between core switches and backbone switches, or for cascade between backbone switches. Note that all optical fiber ports are not stacked and can only be used for Cascade.
Optical jumper crossover
Each vswitch has two fiber-optic ports, one for one request. Of course, the optical fiber jumper must also be two; otherwise, communication between ports
capabilities of the console and command line interface, and support for Web, SNMP, and RMON. There are also important performance tests.
We use the industry-renowned network performance tester IXIA 1600 in performance testing. IXIA 1600 can be inserted with a maximum of 16 modules. Our test environment includes 5 10/100 M Adaptive modules, each of which has 4 10/100 Base-TX ports and 6 10/100/BASE-T adaptive LM1000T modules, each module has 2 10/100/M RJ-45 ports; 5
enterprises, the 1000Base-T interface can effectively protect their original investment in wiring.
The Gigabit Ethernet switch we tested is basically fixed and modular. The DGS-3308TG Gigabit Ethernet switch has two GBIC interfaces. the GBIC module can adapt to single-mode and multi-mode optical fiber. The 3Com4900 Gigabit Ethernet switch has an expansion slot on the rear panel.
The 1000Base-T/
SUP720, a 16-port Gigabit Optical module WS-X6816-GBIC, A 48-port fast switching electrical module WS-X6548-RJ-45 ). Trunk is set up on the port 6509 connecting the optical transceiver and the corresponding port of the annett switch. The annett switch is divided into two VLANs, 172.25.6.0/24 (hereinafter referred to as VLAN6) and 172.25.7.0/24 (hereinafter referred to as VLAN7), machines in the two Departments are connected to their respective VLANs.
. nonegotiate can only use 1000BASE-SX,-LX, and-zx gbic on these GBIC.Copy running-config startup-config // Save settings(8) Configure EtherChannelSeveral Ethernet ports are bound to an independent Logical Link. For example, you can bind a 4006 vswitch to a maximum of eight compatible ports with the same speed on any 4006 module. Each Ethernet channel has a port-channel port number. To bind an Ethernet chan
From the data, we can see that the bandwidth of the Ethernet switch stack is dozens of times the speed of the switch port, which can effectively improve the network performance, when the number of ports that a single switch can provide is insufficient to meet the requirements of the network computer, more than two switches must provide the corresponding number of ports, which also involves the connection between switches. Basically, there are two ways to connect a vswitch: Ethernet switch stack
The maximum rate of Ethernet switch stack is faster, Which is multiple times faster than the port rate of the switch. Not all switches support Ethernet switch stack, when the number of ports that a single switch can provide is insufficient to meet the requirements of the network computer, more than two switches must provide the corresponding number of ports, which also involves the connection between switches. Basically, there are two ways to connect a vswitch: Ethernet switch stack and cascade.
-port Gigabit Optical Module Ws-x6816-gbic, a 48-port fast switching module ws-x6548-rj-45). Trunk on the corresponding port of the 6509 and Annette Switch connected to the optical transceiver, the Annette switch is divided into two VLANs, respectively 172.25.6.0/24 (hereinafter referred to as VLAN6) and 172.25.7.0/24 (hereinafter referred to as VLAN7), The machines of the two departments are connected to their respective VLANs. The convergence layer
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.