This article reproduced: http://blog.itpub.net/12639172/viewspace-659819/As you know, in ASP. NET, if we modify the configuration file as long as it is saved, it will be immediately reflected in the program,We do not need to restart IIS. We can even replace the files under the application directly without stopping IIS,
--------------------------------------------------------------------------------------------------------------- ---------------------
The 2nd method:
Cause: The memory heap constricted of the standalone process is exhausted, and IIS cannot create more process workspaces to handleWorkaround:1. HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W3SVC2. Create a new DWORD entry under the Parameters key named: Usesharedwpdesktop with a value of 1
Last year, an asp.net website used a large number of caches and restarted iis once in a few minutes. At that time, no reason was found. Some problems occurred during this period and it was suspected that the cache occupied too much memory, not verified
The descriptions are as follows:If memory recycle is not enabled, IIS processes will use 1.3 GB of virtual memory and eventually stop responding. Then, an ev
Key Points This IIS 6.0 feature can be used only when running in Working Process Isolation Mode.
An application pool is a configuration that links one or more applications to one or more worker processes. Because applications in the application pool are separated from othe
IIS application Pool Optimization Scenarios
The server often generates the "Application pool ' DefaultAppPool" process that provides service shutdown times beyond the limit. The process ID is ' 3504 '. "Error, which causes IIS to
I believe most people in the customer environment have encountered a situation where customers are unable to provide accounts with specific privileges, such as the farm Account,sp_install or administrator accounts in the SharePoint system, and the lack of these accounts To run PowerShell, you may encounter a problem with insufficient permissions. After a search, I found that if these accounts were used as app pool identity, you could use Appcmd to get
IIS could not remove the program pool because it contains 1 applications, the problem is shown in the following figure:
the cause of this issue occurs:
Virtual directory A is published under the site, and virtual directory B is published under virtual directory A, choosing to use the same application pool.
This pr
IIS 7 Managed Piping Mode Classic mode (CLASSIC) integration mode (integrated) analysis and understanding
IIS 7.0 supports two pipe modes: One is the latest integrated piping mode provided by IIS 7.0, and the other is the classic piping mode, which is provided by previous versions of IIS.
We can set the pipe mode thr
IntroductionWhether you is running your site on your own server or in the cloud, security must is at the top of the your priority list. If So, you'll be happy to hear this IIS has a security feature called the application pool identity. This feature is introduced in Service Pack 2 (SP2) of Windows Server and Windows Vista. An
startup time is limited to 90 seconds, and the shutdown time is limited to 180 seconds.
Remove the hook for enabling the quick failure protection!In order to avoid having to ignore the prompt when many errors are encountered, you can just increase the protection scope of quick protection. For example, if the failure occurs for 50 times for five minutes, you can close the corresponding program.
The "Closing time limit is 180 seconds" is required. Because the process closing time is originally 90
used (MB): The worker process is reclaimed when the physical memory used by the worker process reaches the set value. The default value is 192 MB if enabled; we recommend that you set it to 60% of the total physical memory size;
In addition, the application pool has the following two ways to recycle working processes, but neither of them will interrupt Web Services:
By default,
I have been writingAnalysis of Technical Principles of the autumn GardenIn this article, I will write a prose article to briefly describe the murder case caused by a small server memory.
In the past, all the texts were typeset. This article is a prose article. After writing the article, I will add the blacklist and the red text.
First, I will first upload two pictures of the current process and memory of the autumn garden Server:
1: Process
2: remaining physical memory
After reading these
, you can not shut down, just to increase the protection of rapid protection, such as the number of failures 50 times the time period of 5 minutes to close the corresponding program."Close time limit of 180 seconds" is required, because the process shutdown time, the original 90-second limit, is the default value, if the process is closed for more than 90 seconds, it is considered time-out, resulting in: Process shutdown time exceeds the limit log, so, appropriate extension of this time, can avo
IIS runs a 32-bit. NET program on a 64-bit subnetBecause the 64-bit operating system does not support Microsoft OLE DB Provider for Jet driversEarlier Microsoft Access Driver (*.mdb) connections are also not supported.So Microsoft OLE DB Provider for Jet used for Access and Excel databases is not available in the 64-bit version, which means that the following two connection strings are not working correctly:"Provider=Microsoft.Jet.OLEDB.4.0;Data sourc
Server CPU, memory normal, some sites can not open, application pool recycling is normal, how to solve?
Questions:
Server \iis and ASP issues I would like to ask next you ' site recently a few times a day to play not open very slowly ' only show tile title other No, the site is ASP, foreground-generated HTML, today saw the W3WP.exe occupancy up to 280M, General
can not browse the page, try any aspx page can not open. A new web application was created with vs.net again.Computer environment:Win2003, vs. net2003Symptom:1) when you want to browse a page, the "server application unavailable" Web application you are trying to access on this Web server is currently unavailable. Please click "refresh" in the Web browser to try
failures in the application exceeds the configured value (5 by default), the application pool is disabled.3. Start Time Limit: IIS waits for the start time of a worker in the application pool. When the start time of a worker exce
the following code, for example, to give empowerment:" IIS Apppool\defaultapppool ":(R)For security reasons, make sure that the file does not inherit other permissions or has many other permissions.Now you are free to set up your own defined profiles for each application pool, and of course, multiple application pools
The later version of asp.net2.0 provides a aspnet.config file at the root of each framework, which is used to configure some of the global information, but we haven't used it in any way.After asp.net4.0, this configuration file is fully supported in terms of concurrency and threading. For example, you can set parameters such as maxconcurrentrequestspercpu, maxconcurrentthreadspercpu , and requestQueueLimit , For more flexibility in setting up the configuration of the ASP.C:\windows\microsoft.net
Error: The application pool "AppPoolName" template permanent cache initialization failed because of the following reasons: Unable to create the disk cache subdirectory of the application pool. The data may contain additional error codes ...
During a restart of the
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.