vnx support

Discover vnx support, include the articles, news, trends, analysis and practical advice about vnx support on alibabacloud.com

New features and enhancements of vnx oe for Block v05.32.000.5.006 and vnx oe for File v7.1.47.5

current quick installation image format, this new File Image format will reduce the deployment time.· Install the vnx oe for File software when the data block is upgraded to the unified storage field: this function supports on-site upgrades from the data block to the unified storage. You can use the existing uniseries Service Manager (USM) the software upgrade tool downloads new data blocks to the unified storage upgrade package (PBU ).·

Overview of vnx oe Block R5.32 and vnx oe File V7.1 hardware enhancements (I)

· 1. These two new I/O modules are suitable for VNX and VNX gateway types: 10GbE Fiber Module only applies to Vnx DM The 10GBASE-T module is suitable for VNX Storage Processor iSCSI and Vnx Data Mover IP 2, X8 pc

Overview of vnx oe Block R5.32 and vnx oe File V7.1 hardware enhancements (IV)

problems that must be fixed, click "View Full Readiness Report for Details" to View the specific Report.The URC detailed report provides the recommended steps to solve the problem.In this example, you can see that vnx oe does not support such a large memory. The Block and File versions must be upgraded to the latest version, namely, Block R5.32 and File v7.1.39.2.Step 2: Perform health check on t

VNX snapshot What is VNX snapshot profile

VNX Snapshot is a new feature of the VNX for blocks OE release 5.32 that can be used for data backup, software development and testing, data validation, local fast recovery, and more. Solution: Profile Currently, VNX Snapshot can only be used for pool LUNs, while raid Group LUNs only support Snapview S

VNX OE block R5.3.2 and VNX OE File V7.1 Data protection and System Management overview

In the new version of the system management functions are mainly the following improvements, this article will be introduced in one. 1, the Unified Network Service function enhances; 2, monitoring and statistical function improvement; 3, FIPS 140-2 Security support. Unified Network SERVICE function improved The Unified Network Service (UNS) integrates CS and SP Basic Network services to provide a

Vnx oe Block R5.3.2 and vnx oe File V7.1 overview of data protection and system management (III)

VNX OE block R5.3.2 and VNX OE File V7.1 Data protection and System Management overview, the article is reproduced from the EMC Chinese Support forum. Solution: FILE-level retention (FLR) is an EMC VNX series software feature that protects files from modification or deletion before a retention date is specifi

Vnx new version features detailed application to Professional and technical advisor (c)

capabilities of the VMware infrastructure to the storage array will help greatly improve the performance of the VMware infrastructure. This is equivalent to "uninstall" part of the VMware Infrastructure (offload) to the underlying storage devices, such as Vnx, VMAX, Vplex, and Vnxe. If an operation does not support VAAI, the array returns an error message to the ESXi host, allowing the ESXi host to perform

Introduction to virtualization in the new version of VNX (2)

The new version adds two more features to virtualization and better integrates the capabilities of VNX and VMware, and this article details the Vaai for multiple snapshots of NFS. VASA (vstorage API for Storage Awareness) Vaai for NFS multiple snapshots (vstorage API for Array integration) Solution: Vaai Function Introduction The array integrated storage API (the Vstorage API for array integrat

VNX for file character shows common problems and solutions

Failure phenomenon: The article is reproduced from the EMC Chinese Support forum. The VNX for file default character encoding is ASCII, which often uses Unicode language character criteria to store, search, and interchange text in any language in a uniform manner. After the system initial installation and platform migration, because the newly installed VNX does

Introduction to virtualization of Lenovo VNX

The new version of the virtualization aspect of the main added two features, better integration of Vnx and VMware features, this article will detail the Vasa. VASA (vstorage API for Storage Awareness) Vaai for NFS multiple snapshots (vstorage API for Array integration) Solution: Vasa function Introduction Vasa is an API developed by VMware that uses vcenter to display storage information. Vasa

VNX block OE 05.32 supports hardware upgrade Readiness Check Introduction

Upgrade Readiness Check Wizard The Upgrade readiness Check (Upgrade readiness Checker) is a new wizard in the USM (Unisphere Service Manager). You can export a TXT-formatted report by importing only the configuration file for the source device. If the storage system is not suitable for upgrades, detailed reasons and solutions are noted in the report. · The Upgrade Readiness Check Wizard prepares for the following three types of upgrades · Upgrade from low-end mo

Introduction to the principles of Vnx and Vnxe snapsure

The article is reproduced from the EMC Chinese Support forum. EMC Snapsure is a software feature for creating and managing file snapshots where snapshots are not a copy or mirror image of the original file system, and the snapshot "filesystem" is just a logical image of the point-in-time of the production file system at a specific time, the file system is a read-only view of the production file system before a change occurs at a specific time. So

Introduction to hardware transformation and upgrade supported by the new VNX version

The new version of VNX supports four types of hardware upgrades Upgrade from low-end models to high-end models Upgrade from Block-Only to Unified storage) Upgrade from single File-Only to Unified storage) VNX7500 memory upgraded from 24 GB to 48 GB As shown In the preceding figure, Data In Placement is upgraded from the low-end model to the high-end model. For example, you can upgrade VNX5300 to VNX7500; the upgrade will not change the

How to collect VNX logs

Failure phenomenon: How do I collect vnx logs and what files do I need to collect? Solution: Vnx needs to collect two copies of the log One is the dump log, which is collected after/nas/var/dump uses the WINSCP login control station. The other is support materials, which requires you to first enter the following command with the SSH login cont

Vnx new version Features--apply to professional and technical consultant

Failure phenomenon: With the release of Vnx's new version of block R5.32 and file V7.1, more and more users in the marketplace are focusing on this version. But many users do not know what the new version of Vnx is all about. Therefore, professional and technical consultants will face more and more problems in this area, in order to professional and technical advisers more comprehensive and systematic answer to the relevant questions, the series

How do I delete the alarm information of all VNX instances at one time?

Failure phenomenon: VNX series, the alarm log is always a piece of the appearance, delete a piece again, how to delete all the vnx alarm information? Solution: VNX for Block: If the Unisphere interface alarm information cannot be deleted multiple times, you can resolve it by restarting the Restart Management Server service;

Introduction to VNX-Block data compression

Fault symptom:Data compression is used to save space. do more with less. VNX File/BLOCK has their own Compression function, today we will briefly introduce the VNX-BLOCK of data Compression, from a conceptual understanding of the VNX-BLOCK Compression.Solution:VNX Block data compressionThe data compression process of the VNX

Introduction to the new version of VNX to the improvement of Fast VP and storage pool (2)

This article is reproduced in the EMC Chinese support forum. EMC released a new version of the VNX operating environment. The new version of the Block system is v05.32.000.5.006, and the new version of the File system is v7.1.47.5. The new version released this time has improved many functions and brought many surprising new features. This article will discuss the improvements and new functions of Fast VP a

Vnx/clariion Dial Home Common error code

, must be collected after the problem occurs (make sure that the problem event is included), and then upload the log to service center or Powerlink. Case 3:storage Processor dials home ' A23 ' event code B 11/04/12 06:42:55 sp A A23 Peer sp down. 3 0 0 This error indicates a peer SP failure, possibly due to suspension, downtime, bugcheck (equivalent to a blue screen of Windows). The hardware for the Peer SP still exists but is offline, and communication between Spa and SPB is interrupted. Thi

How does VNX storage hard drive calculate the actual user available capacity?

Lenovo/emc vnx storage, after dividing the RAID, found that the available capacity and the actual disk configuration capacity does not match.Solution:1. The first four disks in the VNX series are system disks. The system occupies 300 GB of capacity for each of the first four disks. In the VNX2 generation storage, the system capacity accounts for GB;2. For the sake of data security,

Total Pages: 15 1 2 3 4 5 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

not found

404! Not Found!

Sorry, you’ve landed on an unexplored planet!

Return Home
phone Contact Us
not found

404! Not Found!

Sorry, you’ve landed on an unexplored planet!

Return Home
phone Contact Us

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.