acronis com

Want to know acronis com? we have a huge selection of acronis com information on alibabacloud.com

Event Viewer specific permission setting does not resolve a COM server application error _win server

Problem: Application-specific permission settings do not grant user NT a local boot permission for COM server application (CLSID {dcbca92e-7dbe-4eda-8b7b-3aaea4dd412b }) Uthority\system SID (s-1-5-18). You can use the Component Services Administration tool to modify this security permission. Solve: 1, run regedit. Then search dcbca92e-7dbe-4eda-8b7b-3aaea4dd412b, search to the right side of the box AppID REG_SZ string value is {B292921D-AF50

Create a Visual Basic COM component to use in ASP

Profile This step-by-step article describes how to create a Component Object Model (COM) component for use in Active Server Pages (ASP). COM components for use by ASP Create a new ActiveX DLL project in Visual Basic. Name the project VBASPProject and name the class Vbaspclass. Paste the following public methods into the class module: Public Function GetString () as String ' Return the string Hello world!

"WMI-3" WMI for c++/com query information __c++

Query informationOne of the main functions of WMI is to query the WMI repository for information about classes and instances, we can call a synchronous query, or we can call an asynchronous query. A synchronous query is a query that executes at the current execution, and an asynchronous query needs to start another thread to query, and after the query has finished, call the defined interface (similar to a callback function) to handle the query results. Synchronous query is suitable for querying

No COM interface Why Windows Service failed to start and the solution

the artifact--step-one. Startup Failure Reason Once the Window service program is started, a run method is called in the WinMain method Collapsehresult Run (_in_ int nshowcmd = sw_hide) throw () { HRESULT hr = S_OK; t* PT = static_cast The Run method calls the Pt->runmessageloop () method for a while loop, which prevents the WinMain method from returning, causing the program to end. After debugging, found that execution, the Pt->premessageloop method returned S_FALSE, because

Porting ASP code to VB COM components (3)

small example of context conversion in the program. If you test this code, it will run, but please Do not do this within your own application. Private Sub Dostuff () % > This is End Sub % > Programmatic code has some other benefits as well. First you'll find it easier to reuse the parts of the code that are included in the program. Secondly, to Fewer lines of code are required to achieve the same purpose. Third, you will begin to develop a large reusable code base. At first it's The form is.

Using VC + + ATL to implement Office COM plug-ins

Summary This article describes the use of VC + + ATL (Active Template Library), using the IDTExtensibility2 interface to add a simple COM plug-in (addin) to Microsoft Word, Adding visual parts, such as toolbar buttons and menus, and adding a way to respond to events, and at the end of the paper, provides a simple way to implement a hybrid programming with Office macros. When it comes to office-related programming, it's possible that VBA (Visual Basi

COM + Web service: Routing to XML Web services by check box 3

Microsoft c#™ or Visual Basic. NET and inherit from ServicedComponent. The following are examples of managed code for a simple managed component: Using System; Using System.Reflection; Using System.Runtime.InteropServices; Using System.EnterpriseServices; [Assembly:applicationname ("Cssoap")] [Assembly:applicationactivation (Activationoption.server, soapvroot= "Cssoap")] [Assembly:assemblykeyfile ("Cssoap.snk")] Namespace Cssoap { public interface Icalc { Double Add (double Value1, double Val

Retrieving a component of the CLSID {00024500-0000-0000-c000-000000000046} in a COM class factory failed because of the following error: 80070005 access denied. (Exceptions are from hresult:0x80070005 (e_accessdenied)).

Tags: retrieving file log window CDATA LDA component Get StrRetrieving a component of the CLSID {00024500-0000-0000-c000-000000000046} in a COM class factory failed because of the following error: 80070005 access denied. (Exceptions are from hresult:0x80070005 (e_accessdenied)).In Batchimportentrytable.getexceldata (String FileName)Retrieving a component of the CLSID {00024500-0000-0000-c000-000000000046} in a COM

Retrieving a component of the CLSID {820280E0-8ADA-4582-A1D9-960A83CE8BB5} in a COM class factory failed because of the following error: 80040154 There is no registered class (Exception from hresult:0x80040154 (Regd B_e_classnotreg)).

Label:Retrieving a component of the CLSID {820280E0-8ADA-4582-A1D9-960A83CE8BB5} in a COM class factory failed because of the following error: 80040154 There is no registered class (Exception from hresult:0x80040154 (Regd B_e_classnotreg)).IIS program pools, advanced settings: Enabling 32-bit applicationsRetrieving a component of the CLSID {820280E0-8ADA-4582-A1D9-960A83CE8BB5} in a COM class factory failed

VB Error in VS2008 retrieving the component of the CLSID {28e68f9a-8d75-11d1-8dc3-3c302a000000} in the COM class factory failed because of the following error: 80040154 no registration Class (Exception from hresult:0x8 0040154 (Regdb_e_classnotreg)).

Resvr32 the name of the control referenced in. NetIf the registration is successful, the problem does not occur but if the control is registered successfully in a x64-bit system, the error is prompted because most third-party written COM controls only support 32-bit systems, find the project with the reference control in VS--〉 property--〉 generate--〉 general---) Target platform---) Select X86 to solve. The problem of the control is the Opcdaauto.dll f

Java-java-com-util-common-service:serviceexception.java

Tags: style version throwable use height manage Ima ESS nbsp Ylbtech-java-java-com-util-common-service:serviceexception.java 1. back to top 1. PackageCom.shineyoo.manager.util.common.service;/*** Service Layer Common exception, which triggers a transaction rollback when thrown from a function in a spring managed transaction. *@author */ Public classServiceexceptionextendsRuntimeException {Private

SQL Server data import problem: Error "call to COM component returned wrong HRESULT E_FAIL"

The database used by the customer is older, SQL Server 2008, and two SQL files are exported.With the help of OPS, SQL Server 2008 is installed and configured in the WIN10 system.Open the first file, no problem, build the appropriate database, run the script, you can import.The second file encountered a problem, always error "the call to COM components returned a false HRESULT E_fail"The solution that the search engine gives is to start and configure t

Workarounds for exporting Excel exceptions. : System.UnauthorizedAccessException: Failed to retrieve component with CLSID {000209ff-0000-0000-c000-000000000046} in COM class factory

Tags: Microsoft Access cat Information Strong Support access services 32-bitException information is: System.UnauthorizedAccessException: Failed to retrieve component of CLSID {000209ff-0000-0000-c000-000000000046} in COM class factoryFind a solution on the Internet 1. In Start, run, enter Dcomcnfg.exe to start the Component Services 2: Double-click "Computer", "Component Services", "My Computer", "DCOM Configuration" 3: Find "Microso

Cool code: eight lessons from com experience

Original: Jeff prosiseThis article reposted from Microsoft China community: http://www.microsoft.com/china/MSDN/library/windev/COMponentdev/CDwickedtoc.mspxRelease date: 5/20/2004Updated on: 5/20/2004Source: wicked code: eight lessons from the com school of hard knocks (Jeff prosise)In my daily work, I have seen a lot of COM code written by Different developers. I was surprised by many creative ways of work

An error occurred while installing SQL. How to Solve the COM + problem?

If the COM + verification fails, there may be two reasons:1. the COM + service has not been started, or the COM + component itself has an error. The solution is to reinstall COM + (install/uninstall-> Windows Components. Do not change anything. Go to the next step, and then enable the

Com example (3) -- component code

Com example (3) -- Component code This article focuses on this series of articles. The interfaces previously designed are only auxiliary, and have nothing to do with the com thread model. Because the imodule and imodulesite interfaces implemented by the customer and components are packaged with interface transmission, the interface packaging function of MFC is used for implementation. Therefore, all inter

The lifetime of a COM Object)

Lifetime of processing COM objects When an object is created, the system allocates the required memory resources. When the object is no longer needed, the object should be destroyed so that the system can use the memory resources for other purposes. In C ++, you can use new and delete to directly control the lifetime of an object. However, the COM object cannot be directly created or destroyed. The reason i

GUID, UUID, CLSID, and IID in COM

GUID, UUID, CLSID, and IID in COM (15:56:13) ReprintedBytes Tags:It (I have read the article "GUID... COM" on the Internet today, so it is recorded .)When Microsoft designed the com specification, there were two options to ensure that the com component designed by the user could be globally unique

Msdn: mfc atl com ActiveX

Microsoft Foundation Classes (MFC)The C ++ class library thatMicrosoft provides with its c ++ compiler to assist programmers inCreating Windows-based applications. MFC hides the fundamental windowsAPI in class hierarchies so that programmers can write a Windows-basedApplication without needing to know the details of the Native WindowsAPI. Active Template Library (ATL)A c ++ Template LibraryUsed to create ActiveX servers and other Component Object Model (CO

Error 80040154 retreiving com class factory

1. Ask: Greetings, I have a VB. NET application that references a 3rd party COM component. the file is InterOP. wintsrrlib. DLL. my VB. NET application has a project reference to the com Comonent which lives in the directory: C: \ wavetracker. The application runs fine. when I sent it to my customer, he installed in on his desktop machine. it runs fine. then he copied all of the Application Files (whi

Total Pages: 15 1 .... 11 12 13 14 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.