How to create, delete, and restore hard RAID 1 in SunV440

Article Title: how to create, delete, and restore hard RAID 1 in SunV440. Linux is a technology channel of the IT lab in China. Includes basic categories such as desktop applications, Linux system management, kernel research, embedded systems, and open source. On the Sun Fire V440 server, you can use the onboard Ultra-4 SCSI controller to configure the hardware disk image. It performs better than conventional software images that use volume management

Troubleshooting during linux File Server Installation

8139 Nic can be inserted first ). Unlock driver package Tar zxf bcm5700-6.0.2.tar.gz Go to the source code directory Cd src Make Bcm5700.o file will be generated ?? Step 2: insert the kernel module Insmod./bcm5700.o ?? Step 3: copy the kernel module to the/lib/modules/2.4.24/kernel/drivers directory. Cp./bcm5700.o/lib/modules/2.4.24/kernel/drivers Edit the/etc/modules. conf file so that the system can insert the kernel at startup. Vi/etc/modules. conf Add a row Alias eth0 bcm5700 ?? Restart

Storage Fundamentals 1

deploying expensive fibre switch networks to connect traditional storage devices.In recent years, the transmission bandwidth of Gigabit Ethernet (1000Mbps, 125MB/S) has gained popularity and is expected to evolve towards Gigabit Ethernet. By then, the transmission bandwidth of the Ethernet will be 10 times times the transmission bandwidth of the various SCSI and Fiber channel protocols that the San relies on to survive. EMC company Celerra Products s

CentOS 6.5 Environment leverages iSCSI to build San Network storage services and server-side target and client initiator configuration

Introduction iSCSI (Internet SCSI) technology developed by IBM Research, is a hardware device used by the upper layer of the IP protocol can run the SCSI instruction set, which can be implemented on the IP network to run the SCSI protocol, Allows routing to be routed on such high-speed Gigabit Ethernet. iSCSI technology is a new storage technology that combines e

How lsusb works

device, which generally corresponds to a specific driver. The secondary device number is generallyDifferentiate different attributes, such as different usage methods, different locations, and different operations. This device number is obtained from the/proc/devices file, so the driver is usually in the kernel first,In the directory. The main function of this device number (especially the main device number) is to declare the driver used by the device. Drivers correspond to device numbers one b

How to install the hard disk interface of desktop computer

can be more convenient to build a disk array. Serial data lines due to only the use of four-pin structure, so compared with the mouth installed more convenient, more conducive to reducing the cable in the chassis, conducive to heat dissipation. Scsi SCSI (Small Computer system Interface) is a kind of storage cell interface model specially designed for small computer system, which can carry out dynamic di

Hard Drive Introduction

(i) The concept of hard disk and its composition First of all, the concept of the hard disk: RTHK called the HDD, English name: Hard disk Drive, referred to as HDD, hard disk is one of the computer's main storage medium, consisting of one or more aluminum or glass-made discs. This is a hard drive: most of the hard drives are made up of a head arm bracket, a rotating shaft, a read-write head, a head arm, a track, a sector, a cylindrical surface, a disk surface. (ii)

File under system32

A branch Access. chm-Windows Help File Accstat. exe-auxiliary status indicator Advapi32.dll-advanced Win32 application interface Aha154x. MPD-SCSI driver Am1500t. vxt-NIC Driver Am2100.dos-NIC Driver Appstart. ani-Animated Cursor Apps. HlP-Windows Help File Audiocdc. HlP-"easy code decoder" Help File Awardpr32.exe-added printer tools B BranchBigmem. DRV-bigmem Virtual DeviceBilladd. dll-dynamic link library (MSW supported)BiOS. VxD-plug-and-play BIOS

Usage of all windows system files

Transferred from: Baidu KnowsUsage of all windows system files A branchAccess. chm-Windows Help FileAccstat. exe-auxiliary status indicatorAdvapi32.dll-advanced Win32 application interfaceAha154x. MPD-SCSI driverAm1500t. vxt-NIC DriverAm2100.dos-NIC DriverAppstart. ani-Animated CursorApps. HlP-Windows Help FileAudiocdc. HlP-"easy code decoder" Help FileAwardpr32.exe-added printer tools B BranchBigmem. DRV-bigmem Virtual DeviceBilladd. dll-dynamic lin

Linux server does not shut down the new hard disk method

Method 1:1. In the boot state, after inserting the disk, execute the command: echo "---" >/sys/class/scsi_host/host0/scan2. See if the command for step 1 is valid and can be verified in/var/log/messages3, execute fdisk-l command to see if you can see the new disk, if not see, you can change the above host0 to Host1 or host2, and so try againMethod 2:1. Insert the disk, make the/PROC/SCSI directory, and then less./

How to: Configure a Linux iSCSI client

:******** ************************negotiated ISCSI params:************************headerdigest:none datadigest:none maxrecvdatasegmentlength:262144maxxmitdatasegmentlength:131072firstburstlength:262144maxburstlength:262144immediatedata:no initialr2t:yes maxoutstandingr2t:1************************attached SCSI devices:************************Host Number:4state:running scsi4 ChannelxxId0LUNs:0attached

Comparative Analysis of the drive architecture of ATA disk in Linux

is an IDE disk drive, the ATA disk will be driven to a HD device. If the drive is ide-SCSI, the ATA device is virtualized into a SCSI host and added to the SCSI middle leve driver layer, the SCSI middle level driver layer will scan the virtual SCSI host and load the scan to

Linux adds a new LUN without rebooting

this document.EnvironmentSUSE Linux Enterprise Server 10SUSE Linux Enterprise Server 9Novell Open Enterprise Server (Linux based)SAN suited for multiple paths to storageThe Linux installation have already been configured to use Device-mapper Multipath I/O (Dm-mpio) per the article "How To Se" Tup/use multipathing on SLES ".The Linux driver for the host base adapters (HBAs) on the system supports rescanning the HBA to detect the addition or Del Etion of storage areas ("SAN disks"). For example,

What is hybrid raid editing

operational expenses related to power, cooling and maintenance.2. Hybrid RAID SolutionFrom a hardware perspective, building a hybrid RAID solution can use any capacity SSD and HDD (though the number of SSDs and HDDs must be the same). If the RAID array uses a different drive size, the drive capacity is the smaller one. For example, a RAID 1 With 1 128GB SSDs and 2TB HDDs, the logical device is 128GB. A RAID 10 uses 2 128GB SSDs and 2 2TB HDDs, and the logical device is 256GB. The remaining HDD

AIX disks and file systems

the host, connect to the hard disk, and then restart. The system will automatically assign a physical volume name to the new hard disk-hdisk If you want to connect to an external hard disk through SMIT, enter smit makdsk in the command line and you will see: Disk Type Move cursor to desired item and press Enter. [TOP] 1000 mb scsi 1.0 gb scsi Disk Drive 1000mb16bit sc

How to add a new hard disk without shutting down a Linux Server

How to add a new hard disk without shutting down a Linux Server Method 1: 1. After the disk is inserted, run echo "---">/sys/class/scsi_host/host0/scan 2. Check whether the command in step 1 takes effect. You can verify it in/var/log/messages. 3. Run the fdisk-l command to check whether the new disk can be seen. If not, replace host0 with host1 or host2 and try again. Method 2: 1. Insert the disk, run the/proc/scsi directory, and then less./

Linux server does not shut down new hard disk method, linux new

Linux server does not shut down new hard disk method, linux new Method 1: 1. After the disk is inserted, run echo "---">/sys/class/scsi_host/host0/scan 2. Check whether the command in step 1 takes effect. You can verify it in/var/log/messages. 3. Run the fdisk-l command to check whether the new disk can be seen. If not, replace host0 with host1 or host2 and try again. Method 2: 1. Insert the disk, run the/proc/scsi directory, and then less./

Three Advantages of Fiber Channel Technology Access

Advantages of Optical Fiber As the successor of SCSI technology, fiber channel technology has three main advantages compared with its predecessor: Connection distance, scalability and performance. 1. Advantages of connection distance We all know that SCSI Cables cannot exceed 25 m at most, and this is only a theoretical value. In practice, when the number of devices on the

Each hard drive number meaning

I. SeagateSeagate Technology Corporation (Seagate Technology) is a veteran brand in the hard disk world, and the vast majority of users are already familiar with it. As the world's largest disk drive, disk and read-write head manufacturer, the company is always a ibm,compaq,sony and other industry major hard disk suppliers, the company's strength is evident! Seagate is one of the first hard drive brands to enter the Chinese market and has a significant role in the

Solution to server hard drive detection failure

Unit recently bought a new HP ProLiant DL385 server, while purchasing an HP Smart array G2 disk control array card, configured with 10 146GB of capacity of 10,000-turn SCSI hard drive, now I intend to make these 10 SCSI hard disk raid 5, so that the disk array system to maintain a large number of multimedia information task. To do this, the author quickly opened the server chassis shell and then carefully i

Total Pages: 15 1 .... 9 10 11 12 13 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.