Porting from Putty version to Xshell's color scheme, it works well and looks very comfortable.1 [Myisayme]2Text (bold) =Eaeaea3Magenta (bold) =ff55ff4text=FFFFFF5green=a7e22e6Red (bold) =fb26087Green (bold) =a7e22e8Black (bold) =7371719black=737171TenRed=fb2608 OneBlue=009DDC ABlue (bold) =009DDC -Yellow (bold) =66d9ee -cyan=ffd204 theCyan (bold) =ffd204 -yellow=66d9ee -Magenta=ff55ff -Background=222222 +White=D9d8d8 -White (bold) =FFFFFF + Fore A [Names] atCount=1 -Name0=myisaymePutty version o
1. Euclidean distanceequation: Euclidean distance between two n-dimensional vector A (x11,x12,..., x1n) and B (x21,x22,..., x2n): It can also be expressed in the form of a vector operation: application: The analysis of the difference in the numerical size of the dimension, such as the use of user behavior indicators to analyze the similarity or difference in user value. 2. Cosine distanceequation: angle cosine of two n-dimensional sample points a
Recently, some EDI projects are underway. There is a BizTalk 2006 R2 and webmethods7.1 environment at hand. So I want to try sending EDI from BizTalk to webmethods.
Test scenario: Biztalk captures an EDI X12 810 file from the local folder and sends the file to webmethods. Webmethods returns an ACK to BizTalk after receiving the file.
Tutorial steps:
1) Create the partner Information in BizTalk.
Create a partner in BizTalk. Because it is only a
". The target folder is \ processedi_testlocations \ scenario_a \ toordersystem. The file name is "sending messageid=.txt", and select sendorderfilepipeline as the sending pipeline.
10. Configure the subscription conditions in the subscription attribute of the sending port, as shown in.
BTS. Export eportname = receiveedi_fromthem_a
11. Create a New File Sending port named tothem_997. The target folder is \ processedi_testlocations \ scenario_a \ tothem_997, the file name is messageid=.txt, and
resulting polynomial should meet the following criteria:A, the highest and lowest bits of the generated polynomial must be 1.b, when the transmitted information (CRC code) any one error, is generated polynomial modulo 2 after the addition, should make the remainder is not 0.C, different bits when errors, should make the remainder different.D, the remainder to continue to do modulo 2 in addition, should make the remainder cycle.The main generation polynomial g (x) has the following types:
Pipeline Medium Use Batchmaker component , EDI receive Pipeline The specified Component , But if Receive Pipeline Receive non- EDI Type of data, that is, not used EDI receive Pipeline You need to customize Receive Pipeline , In Resolveparty Phase embedding Batchmaker component And then deploy it Biztalk Application . Of course, you can also manually upgrade these contexts through encoding.
2. only one filter rule Party hour , promoted context make the foll
(generator polynomial): When the CRC test, the sender and receiver need to agree with a divisor, that is, to generate a polynomial, generally written as g (x). The highest and lowest bits of the generated polynomial must be 1. The common CRC code generation polynomial is:Crc8=x8+x5+x4+1Crc-ccitt=x16+x12+x5+1Crc16=x16+x15+x5+1Crc12=x12+x11+x3+x2+1Crc32=x32+x26+x23+x22+x16+
as text ("Hello"), and are defined as ANSI or Unicode versions, depending on the compiler's settingsThe string also has a majority of its generic versions:The maximum length version is one more parameter than the standard version, which indicates the length of the bufferWith v whose arguments are parameter list pointers, use Va_list, Va_start, and Va_end macrosC-provided string function: ASCII wide character general form1. Variable parameters:Standar
ProblemToday in the learning process communication-signal Signal–linux kernel anatomy (ix)Met with a strange questionof ‘oldact’ isn’t knownSo Fq to Google.Analysis for a long time, finally found the cause of the problem. and write it down.FoundThe code for the test is as follows#include #include #include #include int main(){ struct sigaction act; return0;}
gcc test.cCompile by default with no errors
gcc test.c -std=gnu99and gcc test.c -std=gnu9x Error-free
used up.Handle strings carefullyThis part will take some time to discuss how to process strings in COM code. If you are familiar with Unicode and ANSI and know how to convert them, you can skip this part; otherwise, you can read this part.At any time, as long as the com method returns a string, this string is a unicode string (this refers to all the methods written to the com standard ). Unicode is a character delimiter set, which is similar to ASCII
which string parameters are sent to the function. The default value is CharSet. Ansi.EntryPointThe DLL entry point to be called.ExactSpellingControl whether entry points should be modified to correspond to character sets. Different programming languages have different default values.PreserveSigDetermines whether the managed method signature should be converted to an unmanaged signature that returns HRESULT and the returned value has an additional [out, retval] parameter.The default value is tru
I. INTRODUCTION of CRCFirst here is what is CRC: Cyclic redundancy Code Check English name is cyclical redundancy check, referred to as CRC, it is the use of division and the remainder of the principle of false detection (error detecting). In practical application, the transmitting device calculates the CRC value and sends it along with the data to the receiving device, and the receiving device recalculates the CRC to the received data and compares it with the received CRC, which indicates that
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.