Impi not detailed description of what to do, can be in the article in the annex below the detailed description, have a very good patience of friends can carefully read.Let's take a look at how the Impi function is set on the Dell server, taking R720 as an example, and the other models are similar:You can see the following settings in the Idrac network settings650) this.width=650; "src=" http://s3.51cto.com/
array card itself, the BIOS of the array card. (typically used to reinstall a system or without an operating system, create a container (Adaptec array card)/logical drive (Ami/lsi array card).Use the Configuration tool software provided by the third party to achieve the management of the card. such as Dell Array Manager. (These software is used for the operating system already installed on the server)Third
On the afternoon of March 30, 2015, colleagues came out from the computer room and told me that the server disk is bright yellow light.I went to the computer room and saw the problematic server. The Dell r720 front panel flashes:Fault detected on drive 0 in disk drive Bay 1. The Chinese meaning is approximately: in Drive Bay 1, Disk 0 detects a failure.Disk 0 LED
The site environment has two units of 06 annual output of the Dell R710 Server, RHEL5.4 operating system, an application server, an Oracle database server, hardware configuration, operating system, independent array card.A computer room power outage, air conditioning does not work, the engine room
Server Purchase guide creates a perfect network server-Linux Enterprise Application-Linux server application information. The following is a detailed description. Network servers can be said to be the core of the entire network. It is important for decision makers and technicians to consider how to select servers that
How to configure and install centos on the DELL R710 Server
At the time of writing this article, I just installed a DELLR710 system. Install the system on the server for the first time. The article will not describe the installation process in detail, there are many online. It only describes the problems I encountered.
In fact, the
Centos 7 mounts a raid 10 hard drive to the Dell R730 Server
The company purchased a new Dell R730 server with two SAS hard disks and four SATA hard disks respectively. SAS hard disks constitute RAID 1 and SATA constitute raid 10. Install Centos 7 on the server and set RAID
Virtualization of DELL server account opening and hyper-threading EnabledR410 R7101. Press the F11 button in the upper-right corner of the boot screen, and EnterBiosBootingManager will be displayed after you press it. In a short time, you will enter BIOS settings.2. Enter the BIOS option, select "SystemSetup", and press Enter.3. Select "ProcessSettings" and press Enter.4. Click the tab, select "Virtualizati
◆ 1. For WINDOWS systems, password breaking software can be used to break the password, but it is different for LINUX systems. The following describes the specific operations:
1. After the server is restarted, press the key e to select the second item in the last three items, press the key e, enter linux single (single user mode), and press Enter.
2. Press the second key B and enter bash (clear password) and press Enter.
3. Enter passwd root and pr
-addons#baseurl=http://mirrors.163.com/centos/$releasever/addons/$basearch/#gpgcheck =1#gpgkey=http://mirrors.163.com/centos/rpm-gpg-key-centos-6# Additional packages that could be useful[extras]name=centos-$releasever-extrasbaseurl=http://mirrors.163.com/centos/ 6.5/extras/$basearch/gpgcheck=1gpgkey=http://mirrors.163.com/centos/rpm-gpg-key-centos-6#additional Packages That extend functionality of existing packages[centosplus]name=centos-$releasever-plusbaseurl=http:// mirrors.163.com/centos/6.
Dell Server hardware monitoring software Openmanager, can monitor the battery, motherboard, temperature, and hard disk and so on. In monitoring, you may experience the following error message:
Info:memory Module 6 [DIMM7, 2048 MB] needs attention:single-bit warning error rate exceeded, single-bit failure error RA Te exceeded
This indicates a problem with memory monitoring, may be loose memory, and so on,
Here are the steps to import a foreign hard drive into an array card, please do so when you are sure the data is backed up, and only provide references .Today, the Dell 720 system fails to boot up the monitor to see if there is a problem with the raid;1. Start the boot by pressing "ctrl+r" to enter the raid settings.2. enter PD Mgmt to view the status of the failed disk (foreign: foreign, Online: normal, missing: Disk not found, failed: failed)3. If t
Server: dell™poweredge™860
System: Windows 2003 R2
Problem: Install the 2003R2 version, the BIOS can identify 4G memory, after installing the system, can only recognize 256MB memory.
"How to solve the problem"
Enter BIOS as shown:
Setting the original OS Install Mode = "on" to "off" solves the problem that the
DELL
1. Install the DEST tool on the local sideHttp://www.dell.com/support/article/cn/zh/cnbsd1/SLN287927_zh/zh?c=cns=bsdcs=cnbsd1l=zh2. connect idrac port ( Span style= "Font-family:simsun;" lang= "en-us" xml:lang= "en-US" >192.168.0.120 0 segment ip , interworking on the line. 3. The administrator runs the dest CLICommand : dellsysteminfo.exe-s 192.168.0.120-u root-p calvin-n root/dcim-d hw,st-r c:\logIdrac User name Root Password Calvin (password is the default password)4. You can a
On the Dell R410 server, Debian 6 is issued by datahunter at, 28/11/2011 -.
Downstream PDF text
Update Time: 2/2/2012
Installing Debian on Dell R410 has a problem,
No Nic bnx2 driver (Broadcom NetXtremeII)
The reason is that it is non-free ....
There are two solutions:
1. The simplest
After the complete security of Debian, the lower-end firmware-bnx2.deb to n
if the value of await is much higher than the value of SVCTM, the I/O queue waits too long for the applications running on the system to become slower.- C parameterIostat can also be used to get CPU partial state values:Iostat-c 1 10avg-cpu:%user%nice%sys%iowait%idle1.98 0.00 0.35 11.45 86.22avg-cpu:%user%nice%sys%iowait%idle1.62 0.00 0.25 34.46 63.67Common usageIostat-d-K 1 #查看TPS和吞吐量信息 (disk read and write speed in KB) iostat-d-M 2 #查看TPS和吞吐量信息 (disk read and write speed in MB) iostat-d-x-k 1
Dell server operations
1. Raid problems:
# Deleting existing Raid configurations
MegaCli64-CfgLdDel-LALL-aALL
# Obtain the device ID and Slot Number
MegaCli64-PDList-aALL | egrep 'enclosure Device ID | Slot Number '| awk 'nr % 2 = 0 {print $3}; NR % 2! = 0 {print $4 ;}'
# Create Raid5, $ sdaslots is the disk ID and slot number used to create Raid that meet the parameter requirements. The size is 500 GB.
Meg
.jpg "title=" Store 7.jpg "alt=" Wkiol1d_aiicykhcaadktvn3eug556.jpg "/>Ok! The expansion of the virtual host disk is complete. View the results. The disk space is getting bigger. The whole process of the original disk is a data storage. Directly after the online expansion. No data loss found. If the data is very important. Please back up beforehand.650) this.width=650; "src=" Http://s2.51cto.com/wyfs02/M00/83/E9/wKioL1d_aW6D_12KAAKIFUbljHw091.jpg "title=" Chunchu7.jpg "alt=" Wkiol1d_aw6d_12kaaki
A few days ago, the company purchased a new server, DELL R720. After installing and installing CentOS 5.6, it found that only lo exists and there is no eth * Nic, after several queries, rhel5.x or centos 5 was installed for newer machines such as r620 and r720. x system, without its NIC driver, so we need to install it ourselvesNIC Driver, http://zh-cn.broadcom.com/support/ethernet_nic/downloaddrivers.phpWe
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.