dnp3 rtu

Want to know dnp3 rtu? we have a huge selection of dnp3 rtu information on alibabacloud.com

Automatic Grid Scheduling System

towards integrated digital network (ISDN) and require the entire network to be connected to other large networks. This requires that the equipment be technically advanced and adaptable. Channel Scheme DesignBased on the above features, the Power Grid Scheduling Automation System is designed to take into account other systems for power communication channels. Channel requirements of existing systems. Automatic Grid Scheduling System: consists of the Main Station System and

Configure IPv6 in Windows XP

interfaces and their related information (including interface indexes). If you need to view a specific interface, For example, in interface 4, you can execute "IPv6 if 4. 3. IPv6 ADU ifindex/address [life validlifetime] You can use this command to add an IPv6 address to an interface. For example, if you want to add an IPv6 address to interface 4 3ffe: 321f: 1/64, You need to execute the following command: IPv6 ADU 4/3ffe: 321f: 1 Someone may ask, why didn't you specify a subnet mask? No way. Th

"STM32. Net MF Development Board Learning-05" PC Remote control Development Board via Modbus protocol

Since 2002 began to contact the Modbus agreement, in the future in the PLC, DOS, Windows,. Net Micro framework, such as the use of the Protocol, in my previous blog to write a detailed record of this experience, interested friends can look at the " My Modbus slave/client development process (RTU/ASCII/TCP). The protocol is open, concise and reliable, at present most intelligent instruments, intelligent modules and some PLC have adopted the protocol, s

Implementation of simple Modbus protocol based on AVR128

Tags: modbus AVR atmega128Modbus communication protocol was developed by Modicon company in 1979 and applied to the Fieldbus protocol for industrial field control. The Modbus communication system consists of a chip node with programmable control and a common transmission line, which is designed for collecting and monitoring multi-node data. Modbus protocol adopts master-slave mode, the communication system has one host to monitor multiple nodes from the machine, the slave node supports up to 247

Modbus Protocol Handout

Tags: http io strong ar data div sp on CModbus an industry-commonly used communication protocol, a communication convention. Modbus protocol includes RTU, ASCII, TCP. One of the most commonly used modbus-rtu, relatively simple, on a single-chip computer is easy to achieve. Although the RTU is relatively simple, but look at the protocol materials, manuals said too

Configuration King Modbus TCP datagram format

warrantyThe register address is 00 08, and similar data address formats are often used in configuration software and PLC systems.Map address Use function code address type access Method description0xxxx01,05,15 discrete output read/write each volume represents a single switch bit1XXXX02 discrete input read-only each volume represents a single switch bit2xxxx03,04,06,16 floating-point register read-only/read-write two consecutive 16-bit registers represent a floating-point number3xxxx04 Input Re

IT knowledge collection

1. RTU The function of RTU is to collect the amount of analog data and State data that indicate the operation status of the power system in the power plant or substation, and monitor and transmit these analog data and State data to the scheduling center, execute the control and adjustment commands sent from the scheduling center to the power plant or substation. The new-generation csseries

Application of GPRS in the scheduling and Monitoring System of Water Supply Network in the tap water industry

Application of GPRS in the scheduling and Monitoring System of Water Supply Network in the tap water industry I. project backgroundThe main purpose of the urban water supply network scheduling and monitoring system is to solve the problem that the water supply company collects and monitors the data of the monitoring points in each stage of water supply. The system consists of a monitoring center and various monitoring sites. The data collection terminal (RT

Use of Nmodbus

Tags: number status control wait art GIS nts use putsIn a recent project, we need to use Modbus RTU to communicate with PLC, and now we will use the process record for future reference.First, what is the Modbus communication protocolThe Modbus protocol is a common language applied to electronic controllers that supports traditional RS-232, RS-422, RS-485, and Ethernet devices.Modbus function code 01 READ COIL STATUS

Industrial Safety introduction of Modbus (reprint)

methods. The PDU consists of a function code and a data segment of the Modbus frame. Figure 51 is an example of the Modbus serial protocol, also known as Modbus RTU. (Translator: Note that the ADU contains a PDU, both of which contain relationships)Figure Wuyi RTUThe Modbus RTU protocol differs from all other implementations of Modbus, including the Modbus on the Modbus+,modbus Ascii,modbus TCP/IP,TCP/IP a

Implementation of simple Modbus protocol based on AVR128

Modbus Communication Protocol Modicon company 1979 in the development, applicable to industrial Fieldbus protocol control. The Modbus communication system consists of a node of the chip and a common transmission line with the composition programmable control, which is designed to collect and monitor data from multiple nodes. Modbus protocol adopts master-slave mode, communication system has multiple nodes from a host computer monitor. Supports up to 247 nodes from a node. Each slave has its own

ETHERNET/IP of the introduction of industrial safety

This article is still the agreement level, the agreement level will translate three, the next one is used in the power system more DNP3. Most of the information quoted in this article can be accessed, with only one writeup on the reversemode.com (Http://reversemode.com/downloads/logix_report_ Basecamp.pdf) requires identity authentication to download, if a friend can download and share.ETHERNET/IPCompared with Modbus, ETHERNET/IP is a more modern stan

Install IPv6 in win xp and WIN 2 K

◆ Configuration commands in WindowsXP/Windows2003:The IPv6 protocol stack is built in Windows2003. We recommend that you upgrade WindowsXP to SP1 at least. 1. First install the ipv6 protocol stack C: \> ipv6 install 2. If you are accessing from a pure Ipv6 network environment, you can get the IPv6 address and access the IPv6 Site.Appendix: Some Common commands:C: \> netshNetsh> interface ipv6Netsh interface ipv6> add address "Local Connection" fe80: a520: 1314: 1/* set a fixed IPv6 address */Net

IFIX System Configuration Guide

, Inc. See http://www.matrikon.com for detailsPLC-modicon:Mb1: it has two versions, 6.x and 7.x. It connects to all devices that support ModBus serial communication protocol through a serial port. It mainly includes modicon PLC and other control instruments such as Honeywell UDC, UMC, and Moore control instruments. Supports the mobus RTU and ASCII communication protocols. When using it to communicate with other compatible devices, note that the data t

Windows Mobile development: creating databases and tables

Using system;Using system. Collections. Generic;Using system. componentmodel;Using system. Data;Using system. drawing;Using system. text;Using system. Windows. forms;Using system. Data. sqlclient;Using system. Data. sqlserverce;Using system. net;Using system. IO; Namespace winappgrid{Public partial class form1: Form{Public form1 (){Initializecomponent ();}// Create a database tablePrivate Boolean createtable (){Try{Sqlceconnection myconn = new sqlceconnection ("datasource = mysdf. SDF ");Sqlcec

Gray hat hackers: Ethics, penetration testing, attack methods, and vulnerability analysis technology of Justice hackers (version 3rd)

meaning of Cross-Site Scripting 318Chapter 4 OIP attack 17th17.1 what is VoIP 32317.2 protocol used by VoIP 32417.2.1 session 32417.2.2 Megaco H.248 32517.2.3 H.323 32517.2.4 TLS and dtls 32617.2.5 SRTP 32717.2.6 zrtp 32717.3 VoIP attack type 32717.3.1 enumerative 32817.3.2 sip password cracking 32817.3.3 eavesdropping and group capture 32917.3.4 dos 32917.4 how to prevent VoIP attacks 335Chapter 4 SCADA attack 18th18.1 meaning of SCADA 33718.2 protocols used by SCADA 33818.2.1 OPC 33818.2.2 IC

Detailed functions of NGN User Access Technology

traditional access network to an NGN user access technology. The original switch access is changed to a Softswitch access. Method 3: The Access Gateway AMG5000 is connected to the softswitch network after the voice passes through DSLAM, same as that of common POTS users. This solution is applicable to the creation of a DSLAM community. When DSLAM is used to access broadband services, it also provides VoIP voice services with AG devices; The Access Gateway AMG with the wide and narrow band compr

Freemodbus port description ZZ, freemodbus port zz

obvious start or end operator, but is determined by the interval between frames. If no new character data is received within the specified time, the new frame is considered to have been received. The next step is to process the data. The first thing to do is to determine the validity of the frame. Modbus determines whether the frame is accepted by time. It is natural that the timer in the single chip microcomputer is used together. ThuOverall code The following is a simple example of using free

Thermal Basement Wireless Monitoring solution

, high flexibility, stable and good2, the current outdoor open interior point-to-point measurement can be up to 12KM3, support multi-point-to-point, point-to-multipoint, in-network broadcast, and other flexible self-networking mode, support star/tree/mesh network,4, self-encrypting des/aes/3des and other wireless encryption5,6 Road Customizable AD capture/io control interface, support standard Modbus Transfer ProtocolThe application of Wbee 1002 System not only simplifies the basement network co

Yifan industrial control automation Overview

[Introduction] Siemens cp243 Communication Control Http://blog.csdn.net/yefanqiu/archive/2005/12/12/550739.aspx [Download connection] Http://www.softreg.com.cn/Detail/ABD6C061-1C30-4AD8-9D81-552116813786/index.html 3. modbus_rtu Industrial Control [Introduction] Modbus RTU communication control Http://blog.csdn.net/yefanqiu/archive/2005/11/20/533315.aspx Development of Modbus TCP to Modbus RTU Protocol c

Total Pages: 9 1 .... 3 4 5 6 7 .... 9 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.