emc vnx2

Want to know emc vnx2? we have a huge selection of emc vnx2 information on alibabacloud.com

Defects of online storage data compression technology

). With the duplicate data deletion technique, the data is not changed, but the copy data about 2-n times is deleted, and the indicator is inserted into a "main instance" of the data. A single instance can be treated as a duplicate data deletion. Traditional data deduplication is often not suitable for online software or primary storage software, because the algorithms needed to replicate data removal inevitably increase response time, which leads to increased costs. For example, popular de-dup

Exchange 2010 Database Disk defragmentation

Tags: database target style title blankFirst step into the bin directory under the Exchange 2010 installation directoryYou can use the command CD in Exchange in PowerShell $Exscripts enter the scripts directory of the Exchange installation directory and type the CD: and CD. \ bin into the bin directory.650) this.width=650; "height=" 216 "title=" image "style=" Border:0px;padding-top:0px;padding-right:0px;padding-left : 0px;background-image:none; "alt=" image "src=" http://img1.51cto.com/attachme

Invalid database copy of Exchange Server 2010 Frequently Asked questions cannot be deleted

PhenomenonAfter the server creates a copy, the display database resides as shown below, and after all visible databases are deleted, a copy is still prompted to delete the issue.650) this.width=650; "title=" clip_image002 "style=" border-top:0px;border-right:0px;background-image:none; border-bottom:0px;padding-top:0px;padding-left:0px;border-left:0px;padding-right:0px, "border=" 0 "alt=" clip_ image002 "src=" http://img1.51cto.com/attachment/201410/9/1056852_1412825235rLzo.jpg "height=" 353 "/>A

Install Oracle on bare devices on AIX

small, you need to adjust it to 32 GB.Smitty chpsView the/tmp directoryDf-kTmp space at least 4 GB View APARInstfix-I-k "IY68989 IY68874 IY70031 IY76140 IY89080" 2. Create oinstall and dba combination oracle users# Mkgroup-A oinstall# Mkgroup-A dba# Mkuser id = 202 pgrp = oinstall groups = oinstall, dba home = '/u01/app/oracle'Shell = '/usr/bin/ksh' oracle (create the path/u01/app/oracle before running the command)3. System Parameter OptimizationNetwork Parameters and adjustment values to be ad

Proper configuration of PCB decoupling Capacitor

Original article address: PCB decoupling capacitor reasonable configuration Author: ker11f I. Category of decoupling capacitors in PCB The decoupling capacitor can be used for energy storage when the operating voltage of the integrated chip or circuit board is compensated. It can be divided into three types: integral, partial, and inter-board. The overall decoupling capacitor is also called a bypass capacitor. It operates in a low frequency ( Local decoupling capacitors have two functions. First

SMI-S expect more

to claiming that its tape library can be managed in the SMI-S-compliant console, it also provides APIs (application interfaces ), other vendors can use these APIs to manage the ADIC tape library. Currently, EMC uses this method: In the same EMC San topology, the ADIC tape library is displayed in real time together with other San components, however, the specific management work is still implemented through

The importance of 0 ohm resistance, PCB engineering must know

1 : no function is provided in the circuit. It is only for convenience of debugging or Compatibility Design on the PCB. 2 : Jumper can be used. If a line is not used, do not paste the resistor directly (without affecting the appearance) 3 : when the matching circuit parameters are uncertain, use 0 ohm instead. during actual debugging, determine the parameters, then, it is replaced by a component of a specific value. 4. when you want to test the current consumption of some circuits, you ca

Inductance, magnetic beads, and 0 euro Resistance

-euro resistor if it cannot be deprecated. 6. Act as an inductor or capacitor under a high-frequency signal. Inductance is used to solve EMC problems. Such as location, power supply, and IC pin. 7. Single Point Grounding (Protection grounding, working grounding, DC grounding are separated from each other on the equipment, and each of them becomes an independent system .) 8. Use fuses. Because the circuit breaking current on the PCB is large, if sho

Build an IPv6 test environment on the Linux platform and IPv4 Environment

Original link http://www.ibm.com/developerworks/cn/linux/l-cn-ipv6env/ Build an IPv6 test environment on the Linux platform and IPv4 Environment Jiang yingyu , Software engineer, EMC Jiang Ying Yu, IBM software engineer, engaged in uxspi-related software R D and testing Yin yiming Yinym@cn.ibm.com ), Software engineer, EMC Yin yiming, IBM software engineer, engaged in uxspi-related software R D and Testin

Basic competencies and knowledge that communication equipment hardware engineers should have

, power supply circuit design is a hardware engineer circuit capability of the centralized embodiment, a variety of passive devices, semiconductor devices, protection devices, DC/DC conversion Typical topology, there are many parameters, The formula needs to be considered, calculated to.6, the ability of communication and global control:Hardware Engineer in a hardware project, generally in the role of team leader, to the full responsibility of this hardware project, need to coordinate the PCB en

Challenges for terminal antenna engineers under multiple wireless standards

With the popularization of 3G technology and the development of wireless standards and technologies such as LTE, NFC, Bluetooth 4.0, cmms B, and MIMO, mobile Terminals need to integrate multi-band main antennas (supporting 2g, 3G, LTE and other multi-standard), as well as GPS, BT, WiFi, NFC, wireless charging and other antennas. As a result, terminal antenna engineers are facing huge challenges: Antenna size -The cell phone size is getting smaller and smaller.-The 'clear' of the antenna is getti

Section 3 multilayer PCB cascade structure

Before designing a multilayer PCB, the designer must first determine the structure of the PCB based on the circuit size, circuit board size, and EMC requirements, that is, it is decided to adopt a 4-layer, 6-layer, or more layers of the circuit board. After determining the number of layers, determine the placement location of the inner electrical layer and how different signals are distributed on these layers. This is the choice of multilayer PCB stac

Blue growth note-chasing DBA (13): Coordinating hardware manufacturers, six stories: what you see as "servers, storage, switches", dba hardware manufacturers

", which forms multiple links, if a disk is selected from the storage on the host, many disks may be released on the host, which will make the operator unable to choose which disk to operate. To avoid this cumbersome disk link, the multi-path software is used to aggregate multiple paths. It facilitates disk management and load balancing. If one link is disconnected, other links are still available, which will not affect disk access. Several multi-path software: (1) IBM host and IBM storage: RDA

MySQL migration in CentOS 5.6

This week, two sets of EMC storage are migrated, and several intranet database servers are attached to the storage space. You need to migrate the stored database to the server. The specific migration steps are as follows: I. Environment: 1. original database server: 172.28.29.21 (Mount EMC to the/sandata directory) 2. Database Server: 10.20.220.107 II. Specific ideas: 1. Run NFS on 10.20.220.107 and mount/d

Manager agent will not register host with CX

Manager agent will not register host with clariion Array Primus self-service EMC Knowledgebase "Manager agent will not register host with clariion array" ID: Emc125015 Usage: 70 Date created: 12/30/2005 Last modified: 06/13/2006 Status: Approved Au

Problems encountered in pads-emsym angxin Technology

power supply plane is reduced at least 20 times the layer distance between two planes than that of the 0 V plane. This rule is often required to be used as a side-side shooting technique to reduce the plane structure from 0 V/power. However, 20 h rules only provide obvious results under certain conditions. These specific conditions include: (1) The rise/fall time of current fluctuation in the power supply bus must be less than 1ns. (2) The power supply plane must be on the internal layer

A ORA-15031 error is prompted when root. sh is executed

environment and no problems are found.$./Runcluvfy. sh stage-pre crsinst-n node1, node2-verbose$./Runcluvfy. sh comp ssa-n all-verbose 6. Operating System logs, no errors found IBM:/bin/errpt-a> messages. out At this point, you can confirm that, according to the oracle Installation documentation, the current disk permissions fully comply with the installation conditions. In the GI graphical installation process, you can also see the ASM disk, but in the root. sh cannot be passed during executio

Crash of the ASM instance caused by disk Addition

Today, the core system adds a disk (EMCDMX4) to the ASMdg, and then the two nodes of the database RAC are both crash, which immediately becomes a cold sweat. Check log: NOTE: Diskinmode0x8markedforde-assignmentERROR: diskgroupDGIDX1wasnotmountedORA-15032: notallalterationsperf Today, the core system adds a disk (EMC DMX4) to the ASM dg, and then the two nodes of the database RAC both fall into the crash, which suddenly becomes a cold sweat. Check log:

LPC1800 and LPC4300 Boot

When programming and running code from the external flash, it's particularly important to make sure so you have the Boo T pins P2_9, P2_8, P1_2, and p1_1 is correctly connected so this MCU starts execution from the correct memory address . For more details, please see the NXP documentation.If The boot pins is incorrectly set, then this would typically result in the initial default breakpoint set by the Debugge R on Main () is not been reached. You can confirm if this is the case by clicking on s

Beware of it black holes

room. Gigabit Backbone Ethernet Direct access to at least forged cabinet what firewalls, routers, switches, load Balancing yes, I can get him all the way upstairs there is a gym, there is a game room inside the door son, You're going to have to talk to someone about it. Can I help you sir? A typical British London cavity son has the face what hibernate, structs, spring,activemq all give me to do not say code how many lines, the light XML configuration file on 100M multi-gigabit An

Total Pages: 15 1 .... 11 12 13 14 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.