Rh436-configure the iscsi shared disk name and permissions through udev (rhel5.5)

Configure the iscsi shared disk name through udev: [root @ localhost ~] # Udevinfo-qpath-n/dev/sdb/block/sdb [root @ localhost ~] #/Sbin/scsi_id-g-s/block/sdb1IET00020001 [root @ localhost ~] # Vim/etc/ud Configure the iscsi shared disk name through udev: [Root @ localhost ~] # Udevinfo-q path-n/dev/sdb/Block/sdb[Root @ localhost ~] #/Sbin/scsi_id-g-s/block/sdb1IET 00020001[Root @ localhost ~] # Vim/etc/ude

Starwind simulate ISCSI for networked storage management

iSCSI Software Target is an optional Windows Service component that provides a centralized, software-based, and hardware independent ISCSI disk subsystem in a storage area network (SAN). iSCSI devices are shared storage that is accessed through a common TCP/IP network. The official iSCSI Software Target supports Window

Livemigration Four: Configuring an iSCSI Virtual Disk

We've created two iSCSI virtual disks on WSS2008 using iSCSI target Software, and in this article we'll show you how Server1 and Server2 access these iSCSI virtual disks. Server1 and Server2 can use the iSCSI protocol to access virtual iSCSI disks on WSS2008, because the

Customizing the ESXi installation image with a script

We are familiar with the method of customizing ESXi installation image is basically esxi-customizer-v2.7.x to complete, today I give you a new method, this method in ESXI6.0 start more suitable, as for why we try to know more.The Preparation tool requires:ISO files for Vmware-powercli-6.3.0-3737840.exe and Esxi-customizer-ps-v2.4.ps1 and

Configure iSCSI using targetcli

Overview: This article introduces the user-state tool targetcli in Lio to configure the iscsi service. Virtual Machine environment: centos7.x (kernel version 3.10.0-862. el7.x86 _ 64) The IP addresses are 192.168.1.200/201, respectively. Targetcli Installation Centos generally comes with this tool. If you do not have it, you can download it from the official website. Quickly create IP-SAN 1. enter targetcli in the command line to enter the interaction

An example of an iSCSI fault

Tag: iSCSI detected conn error (1011) /Var/log/messages error description SEP 14 04:02:58 kernel: connection4: 0: detected conn error (1011) SEP 14 04:02:59 iscsid: Kernel reported iSCSI connection error (1011) State (3) SEP 14 04:03:01 kernel: connection3: 0: detected conn error (1011) SEP 14 04:03:02 iscsid: Kernel reported iSCSI connection error (1011) State (

Use openfiler2.99 under iSCSI to maximize logical volumes (command line)

Use openfiler2.99 under iSCSI to maximize logical volumes (command line) Use openfiler2.99 under iSCSI to maximize logical volumes (command line) Generally, a logical volume cannot be created in the Web mode to maximize its size. In this experiment, an iSCSI storage is used as an example. The openfiler2.99 operating system has just been set up. Log on to the Web

REDHAT7 Building iSCSI Target

REDHAT7 Building iSCSI TargetDividing new partitions (steps)# FDISK/DEV/SDC# partprobe (update partition table)Create a volume group first# PVCREATE/DEV/SDC1# vgcreate VGMING/DEV/SDC1# lvcreate-l 2g-n/dev/vgming/lvming# LvscanISCSI Target# yum Install Targetcli# TARGETCLI> Backstores/block create/dev/vgming/lvming> CD iSCSI/iscsi> Create Iqn.2016-03.com.ming:aa>

iSCSI Service and Client configuration (Redhat Liunx 7.0)

Providing iSCSI remote block storage servicesiSCSI Block Storage ConceptsThe Internet Small computer System Interface (iSCSI) is based on the TCP/IP protocol, simulating high-performance local storage buses, and reading and managing Remote Storage devices over IP networks. As a SAM protocol, iSCSI can provide storage services to Lan,wan.At present, the highest tr

Heartbeat+iscsi+mysql for dual-machine high availability

8, Heartbeat+iscsi+mysql realize dual machine high availabilityMigration of virtual addressesiSCSI provides storage sharing (MySQL is application also can be FTP web, etc. ) 650) this.width=650; "src=" Http://note.youdao.com/yws/res/21276/0B9FB083AE2248FEA35605DB7AC09BB7 "alt=" Qq20150730161150.png "/>on the iSCSI server: 10.0.2.220There are two disks required. /dev/sdb are used for sharing.(1) Installin

RHCE7.0 answer to the iSCSI client

iSCSI Client Configuration: Yum Install Iscsi-initiator-utils Vim/etc/iscsi/initiatorname.iscsiInitiatorname = iqn.2014-11 ...:D esktop0 Systemctl Restart Iscsid.serviceSystemctl enable ISCSID (communication with server)Systemctl Restart iSCSI (read iSCSI files)Syste

Set up multipath environment testing with iSCSI protocol on VMware Virtual Machine multipath (3)

ConfigurationInitiatorEnd 1. Installing the Initiator software on the initiator host # yum-y Install Iscsi-initiator-utils 2. discover and connect to the Target store on the initiator host # iscsiadm-m Discovery-t sendtargets-p192.168.136.101# The target service is found and the information is written to the/VAR/LIB/ISCSI directory# tree/var/lib/

Linux Server Setup--ISCSI

---service-side---1. Preparing the diskAdd a disk SDD to another virtual machine2. Install the target packageperl-config-general-2.40-1.noarch.rpmscsi-target-utils-0.0-5.20080917snap.ky3.x86_64.rpm3. Modify the configuration file, set the storage disk/etc/tgt/targets.confSet/DEV/SDB to Ip-san's network storage disk.IQN:ISCSI qualified name (ISCSI qualified name)iqn.yyyy-mm.# TGTD Example targets file## Example ISC

How to setup ISCSI target using Tgtadm

1.Start the TGTD service#service TGTD StartThe TGTD service is provided by the package:scsi-target-utils.x86_642.Define an ISCSI target name: (for example)# Tgtadm--lld iSCSI--op new--mode target--tid=1--targetname iqn.2001-04.com.example:storage.disk1.amiens.sys1.xyz3.To View the Currect configuration:# Tgtadm--lld iSCSI--op show--mode TargetFor example, we are

Lenovo thinks station E32 (I217-LM Nic) install esxi 5.1

Because the work requires installing an esxi5.x for the experiment, we bought a thinkstation which is cost-effective. I have considered it before I buy it. I either install the window system directly, install workstation 10, and Virtualize esxi; or install esxi 5.xon bare metal. I chose the second solution, but the problem arises... Thankstation motherboard comes with Nic model: Intel Ethernet connection I

Linux Operations Phase Fifth (ix) ISCSI & CLVM & GFS2

Linux Operations phase Fifth (ix)ISCSICLVMGFS2GFS2(Global filesystem, Version2, the CFS cluster file system, using HA 's information layer, to each node Inform yourself of the lock you hold)CLVM(cluster Logical Volume management, cluster logical volume management, the shared storage into a logical volume, the use of HA's heartbeat transmission mechanism (communication mechanism, for the mechanism of brain fissure processing), each node to start the CLVMD service (start Cman and Rgmanager before

Iscsi installation Configuration

I. software required for the iSCSI server: SCSI-target-utils Listening port: 3260 Client Authentication Method: 1, based on IP 2. User-based, chap (two-way authentication, server verification client, client verification server)     Software required for the iSCSI client: iSCSI-initiator-utils Open-iSCSI Ii. Server Con

Centos6.4 Mount iscsi Network Storage

Yesterday, a linux system was deployed for a customer. the server itself had only GB disks as the system disk. All data is stored in network storage, and network storage (iSCSI) needs to be mounted to the local device. the configuration process is summarized as follows: Windowsserver2008R2 is deployed remotely, I don't know what network storage is like. I asked the customer for a Windowsserver2008iSCSI creation document. Yesterday, a linux system was

Mount iSCSI network storage in CentOS 6.4

Mount iSCSI configuration on CentOS 6.4 1. Install the iscsi support package and start the service.Yuminstall binutils iscsi-initiator-utils kmod-xfs xfsprogs Service iscsi start2. log on to Network StorageIscsiadm-m discovery -- type sendtargets -- portal 192.168.1.100 (storage address)Results: 192.168.1.100: 3260,1 i

iSCSI Workflow Target and initiator

With the exponential growth of enterprise-class data, the traditional centralized storage scheme cannot meet its storage requirements, so the storage area network (storage region Network,san) technology is widely used, but its existence is short, the price is expensive and the construction is complex. IP storage technology based on iSCSI protocol is an emerging network storage technology, which integrates IP network technology into storage I/O, and ha

Total Pages: 15 1 .... 7 8 9 10 11 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.