PB is a good development tool for database management systems, but PB is not very useful in Web and computer interface communication. Fortunately, we have Ole and COM technologies that make it easy for us to use the functions of some components without having to focus on the underlying business logic. There are two methods to use Pb for serial programming: one is to use Microsoft's communication control (MSComm control) and the other is to use Win32 API functions. The following describes how to
Recently, some widgets on some computers were not registered. First, record the method of registering ActiveX controls:1. First, you must determine what controls are missing and you need to register them;
2. Download the corresponding control library in the http://www.dll1.cn;
3. Copy the downloaded control library to the directory c: \ windows \ system32 (when the system is XP );
4. Click Start> RUN> CMD and enter regsvr32 XXX on the console. OCX,
.)
Content of the installation package folder
2. Double-click the register device to register the widget. (This process copies actskn43.ocx to the system directory)
3. Use OCX packaging tools in easy language. (After completion, add one more in the supported database:
Activeskinlib supports libraries)
The registration is complete !!!!
Method 2: download other activeskin installation
)-unknown owner-C:/Windows/system32/000.exe---/
Disable o23 services.Use fileinfo to extract the file information and use bat_do to package and delete it.C:/Windows/system32/svch0st. EXE does not exist.Hijackthis is fixed.
Restart your computer and access the internet. Download pe_xscan to scan logs and analyze the logs. The following suspicious items are found:/=Pe_xscan 07-06-04 by Purple endurer2007-6-11 15:53:26Windows XP Service Pack 2 (5.1.2600)Administrator user group
[System process] * 0
How Program Execute the dynamically generated Delphi Code It is often found that people raise such questions, or the content of the questions is ultimately attributed to this problem.Some time ago, a senior wrote a "execute dynamically generated code", which is a real master. I don't have that skill, but I will only be opportunistic.Three methods are provided here, which are implemented by using third-party components.1. Microsoft Windows Script control (http://www.microsoft.com/downloads/detail
data. (New OPEN: 0)
Size returns the Size of the data in the object.
Whether the status of the State add-back object is enabled.
Data Type specified or returned. The optional parameter is:
AdTypeBinary = 1
AdTypeText = 2
2. WshShell and WshUrlShortcut objects
WshShell object
ProgID Wscript. Shell
File Name WSHom. Ocx
CLSID F935DC22-1CF0-11d0-ADB9-00C04FD58A0B
IID F935DC21-1CF0-11d0-ADB9-00C04FD58A0B
The following table describes the properties relate
Problem:
Compile and run the ocx file under the custom Win CE:
Cocreateinstance of OLE Control {2dad60a1-76cf-4016-8c0d-2cb7d4fcbc2c} failed.>>> Result code: 0x80040154>>> Is the control is properly registered?
Solution:
The Resource Division automatically generated by the system when the Windows ocx file is created. h, stdafx. h, stdafx. CPP ,. RC ,. RC2 ,. vcproj ,. copy all files outside the def file
The newly installed version of XP prompts "cannot open the file: MK: @ msitstore: F:/novel. chm"
Best Answer
I have encountered a similar problem. CHM is a system-provided e-book file format that can be opened directly by double-clicking without any software.
If it cannot be opened, the software may be damaged.
I found several solutions for you:
If the file cannot be opened, you can restore the file association as follows:1. Start running. Enter regsvr32 C:/Windows/system32/hhctrl.
"OK, boundchecker provides a compatibility detection report.3.4 ignore errors
In some cases, we need to ignore some errors reported by the boundschecker, including:
1. false positive. A code segment in the boundschecker specified program has an error, but after careful check, it is confirmed that the program does not have this error, which is a false positive of the boundschecker. After all, a tool is a tool. It can only act according to the algorithm it has developed, so there will be false po
analysis.
By viewing the decompiled Flash code, we can see that in the vulnerability exploitation function, it uses a Sound object and calls its toString () method. Currently, Sound objects are widely used to exploit vulnerabilities. Through this vulnerability, the virtual function table of the Sound object will be overwritten, which will eventually lead to attackers controlling the execution flow of the program.
Sound object:
The toString () method of the Sound object is called:
The followi
-----------------------------------------------------------------------------------
This method can be used to solve the vulnerabilities in FLASH for flexible technology operation.
Right-click "Other Rules" and choose "create hash rule"> "Browse"> "-C: WINDOWSsystem32MacromedFlashFlashUtil9e.exe"> "Security Level"> "basic user"
Then add C: WINDOWSsystem32MacromedFlashFlash9e in the above method. ocx indicates that by default, group measurement only s
task is to execute C:/winnt/system32/dllcache/hh.exe.(2) Register C:/winnt/system32/hhctrl. ocx (regsvr32 C:/winnt/system32/hhctrl. ocx)(3) try to adjust Control Panel-region settings-language
Iv. Solutions for Windows XP system failure to open CHM files1. If your operating system is in English, you only need to change the language settings in the control panel to Chinese.
Start-control panel-data, time, l
other methods. The expansion of iscenenode is zero coupling !! This is what I want.This beautiful story has always been so beautiful when I have been using the DLL engine with large headers.
Story development:Two days ago, I successfully inserted the engine into the ATL ActiveX control. To further reduce the volume, my DLL adopts the static link CRT mode to avoid additional overhead of installing the VC Runtime Library, so I decided to compile all the plug-in code of the engine into static lib
I. Method 1:
Click the pb Environment system tree window, right-click the first tab, and find the control you want and drag it to your window, as shown in:
Ii. Fang 2:
1. symptom: When an OLE control is inserted in powerbuilder and an insert control is clicked, the application is automatically closed,
During online queries, some people say that it is caused by conflicts between ocx (such as Jinshan and superstar). After all, there are a lot of soft
System Error: h8007007e (-2147024770 ). The specified module cannot be found. It's very dull, and it's normal in the past. Then I found multiple ocx, which is definitely because this component is not registered. After the VB library fails to run, msinet is copied from the program. OCX, put it under C:/Windows/systems32, and then enter regsvr32 msinet. OCX. After
Security Settings for WindowsServer2003 + IIS6.0 + ASP servers-component Security Settings A. Uninstall WScript. shell and Shell. application Component, save the following code as. BAT file execution (in 2000 and 2003 systems) windows2000.bat
Copy codeThe Code is as follows: regsvr32/u C:/WINNT/System32/wshom. ocx
Del C:/WINNT/System32/wshom. ocx
Regsvr32/u C:/WINNT/system32/shell32.dll
Del C:/WINNT/system3
SubCatch:MsgBox "request failed, please confirm that the requested information entered is valid"Resume finallyEnd Sub4.3 Format requirements for exporting weekly reports1, do not modify the report format of the weekly, otherwise it will cause the exported data error2, the weekly report of the line is: title, week One days of the specific work content (do not leave blank line, otherwise parse error), weekly summary and plan.3, the last three lines of the weekly report must be: This week's work s
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.