gbic transceiver

Read about gbic transceiver, The latest news, videos, and discussion topics about gbic transceiver from alibabacloud.com

Diagram: Function and connection of fiber optic cable, terminal box, Pigtail

Because the network monitors the long-distance widespread need to use the optical fiber equipment, considers the customer to have the understanding optical fiber connection method The need, therefore below will briefly introduce the fiber optic cable, the terminal box, the tail fiber function and the connection methodThe function of fiber optic cable, terminal box, Pigtail and connection method:Connection relationship:Step 1: Outdoor cable and cable access terminal box, the purpose is to connect

MT6165 schematic data mt6165 reference Design mt6165 data sheet information

The mt6165 is a TD-SCDMA and 2g dual-mode RF transceiver implemented in 40nm CMOS. The intrusion network RF transceiver functions are fully integrated. This document describes the performance objectives of RF. Embed macros throughout your productKey Features-Low cost Dual Mode RF Solutions (GGE and TD-SCDMA). 8 (hspa+)) four-frequency GGE (GSM850/900/DCS/PCS)/three-band TDD (B34/B39/B40) support 16QAM UL/64

Design of Embedded Intelligent Nodes Based on Lonworks Bus

transceiver parameters. The Model file only needs to declare the network variable NVs and configure the attribute CPs and the function module FBs. Therefore, you do not need to be familiar with Neuron C. The serial driver provides an independent interface between the master processor and the slave processor. The entire serial driver consists of two parts: the upper-layer driver provides an interface for the main application; the lower-layer driver co

Research on CAN Bus Test Mode Based on Single-chip Microcomputer

1980s to solve the data communication between many control and test instruments in modern vehicles. Because of its high performance, high reliability, and unique design, the CAN bus has been paid more and more attention, and its application fields are no longer limited to the automotive industry, it has developed into the process industry, machinery industry, textile industry, agricultural machinery, sensors, aerospace and other fields. It is recognized as one of the most promising Fieldbus. 1

Analysis of Bluetooth baseband data transmission mechanism

the bluetooth device used to synchronize other nodes in the micro-network. It is the initiator of the connection process and can maintain connections with up to seven slave nodes at the same time. The slave node is a device except the master node in the micro-network. Two or more micro networks can be connected to form a scatternet ). Figure 2 shows the Bluetooth protocol structure. The baseband layer is located above the Bluetooth RF of the Bluetooth protocol stack, and together with the RF l

Anatomy and refinement of hubs

basically eliminated. However, if you want to use it for Cascade, its speed also has some advantages. AUI port (Figure 3): It is a transceiver interface. It is used to connect a signal transceiver that is connected to a crude cable. It is a 10BASE-5 network standard. Like 10BASE-2, it is also in the past. Power Interface (Figure 4. Yes. How does a Hub work without it? Beside the power interface of our hub,

CAN bus (hardware)

lab. When I first joined the lab, I could ask my teacher or graduate students in the lab. but now they have never done can, and I have to do it myself. the teacher asked me to do this can because no one in the lab has done it before. All the medical instruments previously developed in the lab use 485 bus. The teacher saw the decline of 485, And the can could be dug up. So I want to switch to can. In fact, there are not many things on the hardware for my task. the main reason is that the softwa

The meaning of the route light cat

A modem is a combination of a modulator and a demodulator that allows data to be transmitted over an analog signal transmission line. Through the modulation mediator can use the telephone line to achieve the computer data transmission and communication, of course, the general is to buy the cat alone to achieve dial-up Internet. The route light Cat is a transceiver that converts optical Ethernet signals into other protocol signals. The route Light cat

Tips for really spam prevention

, filtering out the user caused "harassment" of the spam message. But after all, there is no guarantee that users will be completely protected. It's also certain that there are occasional miscalculations. Therefore, the default settings are not entirely easy to use, if you want to make Kaspersky's message protection capabilities more powerful, users also need to set up the Kaspersky software function, according to their actual needs, to adjust it. Kaspersky's mail protection settings are locate

Ring Buffer Bufferc Language Implementation __c language

{ printf ("Please input p|g|e?"); scanf ("%s", opera); Switch (ToLower (opera[0])) { Case ' P ':/* put * printf ("Please input a float number?"); scanf ("%lf", z); Put (z); Break Case ' G ':/* get */ z = Get (); printf ("%8.2f from buffer\n", z); Break Case ' E ': printf ("end\n"); Break Default printf ("%s-operation command error! \ n ", opera); }/* End Switch * * }while (opera[0]!= ' e '); return 0; } In the can communication card device driver, in order to enhance the communication ability o

How Mac and PHY achieve network adaptive

These two days to modify the network card driver to achieve 10/100/1000m adaptive, so the next PHY chip and EMAC driver to the compatibility of 10/100/1000m network environment, recorded here. Network device-side Data link layer is composed of MAC Chip and PHY chip, PHY chip based on the external network environment to complete the automatic negotiation and configuration, drive in accordance with the PHY state to configure the Mac to achieve PHY and Mac work with each other. Now the mainstream n

Fibre port-level connections and types for core switches

a straight line. Use the crossover line to cascade the switch through the normal port. Cascade of Switch Fibre ports Because the price of the switch fibre port is still very expensive, the fiber is used primarily for connecting between the core switch and the backbone switch, or for cascading between the backbone switches. It should be noted that the switch fibre ports are not stacked and can only be used for cascading. Cross-connect of fiber jumper More Wonderful content: http://www.biance

Analysis of WCDMA transmitter

changing as each symbol changes. EVM is also very important for the performance of WCDMA transmitter, because it indicates the modulation quality of the transmitting signal. A large EVM value will result in poor detection accuracy, thus reducing the performance of the transceiver. Frequency error: The difference between the specified carrier frequency and the actual carrier frequency. Due to the adjacent channel interference and low quality detecti

Comprehensive Understanding of mainstream layer-3 switch technologies

necessary means to solve the problem. A proper understanding of these features will be of great help to reasonably apply layer-3 switches. To this end, we will briefly introduce the mainstream features of layer-3 switches. ProCurve5406zl is one of the mainstream three-tier switch products with rich functions on the market. It supports almost all mainstream technologies and protocols and has good standard compatibility. Compared with other products, it has ProVisionASIC technology, which can bet

Smart switch products and key points of purchase

SuperStack 3 Switch 4400 and other Gigabit Ethernet Switching Products, 3Com provides users with a complete set of advanced enterprise-level LAN Solutions. Cisco Catalyst 3550 features The Cisco Catalyst 3550 smart Ethernet switch is a stackable multi-layer switch product that improves network health through high availability, quality of service (QoS), and security. With a series of Fast Ethernet and Gigabit Ethernet configurations, Cisco Catalyst 3550 is suitable for enterprise and Metro acces

Q & A set of IT experts based on D-LINK Switch configuration

IT experts based on the D-LINK Switch configuration Q A set, now there is a huge controversy about the configuration of the D-LINK switch, there may be people do not know how to configure the D-LINK switch, IT doesn't matter, after reading the following parameters, you will become an expert. Company's existing network pattern: All in a network segment, Now IP address is not enough, new purchase of a D-LINK3308TG three layer switch, want to transform the network, do not know how to set the three

How can small and medium enterprises purchase suitable stack switches?

, it does not affect the ability of L2 or L3 switches to forward data packets at the wire speed. Similarly, for multicast services, a large number of multicast data packets must be copied by the switch and distributed to multiple receiving ports. Therefore, the replication performance of multicast packets is the key to ensuring the smooth development of multicast services. Make sure that on the selected vswitch, the replication of multicast packets is completed by the hardware ASIC chip rather t

Focus on the performance competition of several Cisco smart Switches

supports SFM for 256 Gbit/s backboard bandwidth ). Each slot supports 16 Gbit/s and is provided by 8 Gbit/s full-duplex dual-matrix connections to each module. The forwarding rate is as high as 210 Mpps. Supports 192 1 Gbps relay or 576 10/100/1000BaseT ports. The integrated POE (802.3af) supports up to 1152 IEEE-compliant 10/100 ports or 576 IEEE-compliant 10/100/1000 ports. Use common modules and operating system software on all Cisco Catalyst 6500 series chassis. The Catalyst 6500 series pro

Comprehensive Testing Report on mainstream Gigabit access switches

the expansion slots of the tested products. The expansion slots of this test are mostly used to insert Gigabit ports and stack modules. It should be said that the most imaginative thing here is that greenent provides two 8-port expansion slots on the front panel, which can be used for m optical interfaces and is suitable for broadband community construction. The 48-port switch, Netcore, and Lenovo vswitches of D-Link and Tsinghua Ziguang biwei provide fixed configuration Gigabit copper interfac

What is a workgroup-level Fiber Channel switch?

, a frame can be forwarded before it is fully received. Fiber Channel switches are also intelligent. They can provide various Fabric services, including services for locating other nodes on the Network (simple name service). They can automatically establish routes with other switches in Fabric, you can also partition devices to monitor and handle errors. Fiber Channel switches provide many different functions, including GBIC, Fan redundancy and power

Total Pages: 15 1 .... 11 12 13 14 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.