Fundamentals of Integrated Cabling Technology

interference and frequency low amplitude interference of the General Electric apparatus. Safety inspection of integrated wiring grounding system When the integrated wiring system adopts shielding measures, it must have a good grounding system and conform to the following regulations: (1) Protection ground grounding resistance value, the separate

Methods and skills for installing the shielded Cabling System

be worse than that provided by the unshielded system. Part 1 installation of the shielded Cabling System The installation of the shielded wiring system mainly involves two aspects: the floor wiring room and the work area shielding cable terminal and system grounding. In view of the particularity of the shielding system, it is necessary to ensure that the Screen Layer of the cable is in good contact with the Screen Layer of the module and the distribu

Installation and testing of shielded cabling systems

security. For a shielded cabling system, we need to pay attention to the following two points during design and construction: 1. The function of the shielded cabling system requires that all connected hardware use shielded products, including transmission cables, distribution frames, modules, and jumpers. 2. The shielded cabling system must be correctly and properly grounded. If the shielding layer of each connection element of the transmission channel is discontinuous or poorly grounded, the t

How to protect the heat of summer programmable Switches

of lightning disasters Lightning strikes can generate different forms of damage. The International Electrotechnical Commission has called lightning disasters a "major environmental hazard in the electronic age ", transient overvoltage, such as lightning strikes, inductive lightning strikes, and power sharp waves, has become the culprit in damaging electronic devices. From the analysis of a large number of lightning strikes on communication equipment, experts believe that lightning electromagnet

In-depth description of comprehensive lightning protection of programmable Switches

classification and prevention of lightning disasters Lightning strikes can generate different types of damages. The International Electrotechnical Commission has called lightning disasters a "major environmental hazard in the electronic age ", transient overvoltage, such as lightning strikes, inductive lightning strikes, and power sharp waves, has become the culprit in damaging electronic devices. From the analysis of a large number of lightning strikes on communication equipment, experts belie

Detailed rules for use of Lightning Protection programmable switches in summer

classification and prevention of lightning disasters Lightning strikes can generate different types of damages. The International Electrotechnical Commission has called lightning disasters a "major environmental hazard in the electronic age ", transient overvoltage, such as lightning strikes, inductive lightning strikes, and power sharp waves, has become the culprit in damaging electronic devices. From the analysis of a large number of lightning strikes on communication equipment, experts belie

Comprehensive wiring system shielding technology detailed

shielding, grounding theory and product line, to provide the most complete, most comprehensive cable, components and end-to-end total shielding solutions to meet the growing needs of today's network. Of course, the current industry on the shielding wiring system, some of the controversy may also make the user is not very understanding of shielding system. The shielding principle of the FTP cable is different from the balance cancellation principle o

Discussion on integrated lightning protection of SPC exchange program

Commission has called the Lightning Disaster "the electronic era of a major public nuisance," Lightning, induced lightning, power supply, such as sharp wave of instantaneous overvoltage has become the culprit of electronic equipment damage. From a large number of communications equipment in the Lightning case analysis, experts believe that: Lightning induction and lightning wave intrusion caused by the Lightning Electromagnetic pulse (LEMP) is the main reason for the damage of communications eq

Make a watch website, how to change the template with JS

Do a watch website, how to use JS to change the template, Cartier bracelet Love Witness for many couples, this pair of bracelets on his meaning is special, I believe that every couple will love to take a couple ring necklace, of course, this bracelet is completely in line with the lovers between the tokens of things, The beautiful love also needs this Cartier bracelet

Problems that need to be understood when engaging in Power Supply

electric energy. They determine the number of devices in the Power Distribution Device and indicate how to connect generators, transformers, and lines, and how to connect to the system to complete the transmission and distribution task. 9. Current Transformer: The instrument converter is an instrument that converts large current into small current. 10. Transformer: a static electrical device used to change the AC voltage of a certain value to another type or multiple types of AC voltage with th

Analog location and digital location)

line!The most fundamental problem is that the current going through this line is going to two different circuits.Suppose there are two currents, a digital stream, and a model stream starting from the ground at the same time. There are 2 devices, several devices, and modules.If the two circuits are not separated, the loss voltage is V when the model flow is back to the front of the grounding end of the several parts.V = (digital stream + die stream) x

Distribution system for environment design of integrated wiring Room

potential reference point, but it is not necessarily a terrestrial potential. If the grounding system is connected to the Earth by a low resistance path, it is called the Earth. If the grounding system is not connected with the Earth, but is insulated from the Earth, it is called a DC suspension. Usually after the appropriate treatment and grounding, that is, th

Talk about your view of the smart band

From the May 28 this year, the millet bracelet began to pay attention to the smart wearable devices on their own life changes.First, let's talk about the 41-day experience. Starting with the Xiaomi bracelet, the first experience is the motion detection function. It is important for IT personnel to be able to optimize the system to some extent by setting goals for themselves, forcing themselves to keep an ey

Three months the first page of the site, the small partners were stunned

site's core keywords, such as: Bracelets are our core keywords, we can the basis of the bracelet industry segmentation, we can through the Baidu Drop-down box, related search, Baidu index, Baidu Auction background analysis of the key words, such as: Jade bracelet, agate bracelet, bracelet size,

Detailed introduction of Integrated Wiring System electrical protection

point-to-point connection channel, it is very difficult to achieve, because the information plug-in, jumper, and so on are difficult to achieve full shielding, coupled with the corrosion of the shielding layer, oxidation damage and other factors, therefore, no channel can truly block the whole process. At the same time, the shielding layer of the shielded cable has poor shielding effect on the low-frequency magnetic field and cannot resist the low-frequency interference caused by equipment such

Program-controlled switches with reduced economic losses should be completely protected against lightning

floor should not have a telephone switch room. However, some units are restricted by the conditions and do not set up switch rooms in accordance with the above principles. For example, the Programmable switch room of Guangdong Ying hotel is located in the basement room on the building. According to the relevant provisions of IEC1312-1 lightning electromagnetic pulse protection, the building area in the lightning protection area is divided into LPZOB area, the electromagnetic field in the area d

Brief Introduction to comprehensive lightning protection of programmable Switches

Programmable switch room of Guangdong Ying hotel is located in the basement room on the building. According to the relevant provisions of IEC1312-1 lightning electromagnetic pulse protection, the building area in the lightning protection area is divided into LPZOB area, the electromagnetic field in the area does not decay, the switch is greatly affected by the electromagnetic field. Determine the grounding system of the switch The

Analysis of Power Supply and Distribution System for Integrated cabling Data Center Environment Design

called the logic location. In order to make the computer work normally, the DC ground is the zero potential reference point, but not necessarily the ground potential. If the ground system is connected to the Earth through a low-resistance path, it is called a ground connection. If the grounding system is not connected to the Earth, but insulated from the Earth, it is called dc suspension. Generally, after proper treatment,

Introduction to serial port standard for RS-232, RS-422 and RS-485

need to be connected to the final resistance. The final resistance is generally 100 Ω in the RS-422 network, and 120 Ω in the RS-485 network. It is equivalent to the resistance of the characteristic impedance of the cable, because the Characteristic Impedance of most twisted pair cables is about 100 ~ 120 Ω. This matching method is simple and effective, but there is a drawback that the matching resistance consumes a lot of power and is not suitable for systems with strict power consumption rest

Standard and Application of RS-232, RS-422 and RS-485

capacitor C to cut off the DC component can save most of the power. However, the value of capacitor C is a challenge, and the compromise between power consumption and matching quality is required. There is also a matching method using diodes, 10. Although this solution does not achieve true "matching", it uses the clamp action of the diode to quickly weaken the reflected signal and improve the signal quality. The energy saving effect is remarkable. Figure 9 10 6.

Total Pages: 15 1 .... 5 6 7 8 9 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.