Re/cicode Errors (in the Help Select Index > Index tab and Type Hardware and select the "Error messages" topic under th e Hardware Alarms section). *citect Kb-search the KB for the error code. This works for the error 274-"Username or password is incorrect". additional Information:0x10000000 = 268435456 = The Citect error_user_defined_base. Error codes returned by the CTAPI that is less than Error_user_defined_base is Microsoft Win32 ERROR codes. Error codes greater than Error_user_defined_base
production process of short-term production jobs. Function modules include detailed process scheduling, resource allocation and status management, production unit allocation, process management, human resource management, maintenance management, quality management, document control, Product tracking and product list management, performance analysis and data collection modules. At the lower layer of MES, it is an underlying production control system, including DCs, PLC, NC/CNC and
tools to estimate the location coordinates of Bezier points that are difficult to write in handwritten code:With the tools no longer have to worry about drawing curves, and even do not need to participate in the programmer, the artist can also use the HT vector Editor to draw graphics export JSON to the programmer, this is HT for the designer and developer to better fit each other vector design, Programmers do not have to work hard every day with code to draw a variety of devices, such a design
program in charge of a provincial power scheduling system project, which obtained real-time power information from the SCADA system. The communication interface uses an uncommon direct connection to the database (this gateway program connects to SQLServer6.5 at one end and Oralce8.1.6 at the other end ). Since the real-time measurement point is nearly, it is obviously inefficient to update or insert all samples at a time. I have created a memory libr
Project home page (Https://github.com/kenexis/PortableICS-MITM). Unlike Modbus, simple packet replay is not valid for some of the ETHERNET/IP instructions. This makes the attack a little more complicated. However, for most attackers, this difficulty will be negligible as long as the ETHERNET/IP protocol is understood. Once the session handle is determined by negotiation, a man-in-the-middle attack like the previous MODBUS-VCR tool can be implemented by manually changing the serial number.ETHERN
Tag:extsdn directive altmsf and machine information own In a notebook to open two virtual machine a bit card, and too much trouble, put Metasploit target target drone on another machine, IP itself configured a bit, target host: 192.168.137.254 intrusion Machine : 192.168.137.253 on target: Kingview 6.53 version cve-2011-0406 vulnerability, System Win2003 SP0 under the: in the information gathering, the target host opened 777 ports, Baidu found that This port is running a Kingview service, an
MSI is an installation file that requires the system's own msiexec.exe to execute varTempDir =@"D:\UploadFiles\SCADASetupWix.msi"; varStart =NewProcessStartInfo ("msiexec.exe","/I \ ""+tempdir); Start. WindowStyle=Processwindowstyle.normal; Start. CreateNoWindow=true; Process.Start (Start);//. WaitForExit ()However, under 360, a warning pops up. It is considered unsafe to install automatically. There should be a better way.Triggering the installation in CMD will also pop up a 360 warning. And t
integrity test, through infection system files (such as Explorer.exe,userinit.exe,winhlp32.exe, etc.) to achieve covert start-up, through the reduction of system software caused a large number of Internet users infected with the virus, The system cannot be secured by a restore.
18. Earthquake net (stuxnet,2009-2010)
The network is a Windows platform for industrial control system computer worm, it is the first to destroy the real world, rather than the virtual world computer virus, using the S
database holds data on all aspects of the pipeline's oil delivery, while the PowerBuilder application allows engineers to run complex computations to predict potential problem areas. FCMS implementation has been in operation for many years, it is considered as a large project by BP exploration, but the development work is completed in only 6 months. The database now holds 60多万条 records, and continues to grow, although the company archives regularly.
The latest application to develop is the val
Label:Modify the default installation path after installing the virtual machine, I found that my virtual disk files were placed on the C disk, I think there is no way to modify the default storage path. It was later found that it was possible to modify the virtual machine method as follows:" Manage "---> " Global Settings ", Then manually modify the virtual storage location, Migrating an existing virtual machine assuming that our original storage file VDI placed in C:\Users\wei.xu\VirtualBox
Fatal error: it is not used for host 192.168.1.112. After postgres solves the problem of installing postgresql9.2, QT connects to the database: Cpp Code www.2cto. comQSqlDatabasedbQSqlDatabase: addDatabase (QPSQL, test); db. setDatabaseName (sqlscada); db. setHostName (127.0.0.1); db. setHostName (1
Fatal error: it is not used for host 192.168.1.112. After postgres solves the problem of installing postgresql9.2, QT connects to the database: Cpp Code www.2cto.com QSqlDatabase db = QSqlDatabase: a
Release date:Updated on:
Affected Systems:Winlog Pro 2.7Unaffected system:Winlog Pro 2.7.1Description:--------------------------------------------------------------------------------Bugtraq id: 45813Cve id: CVE-2011-0517
Winlog Pro is a SCADA/HMI software package for managing industrial and civil factories.
Winlog Pro has a stack buffer overflow vulnerability when processing malformed packets. Remote attackers can exploit this vulnerability to exec
Release date:Updated on:
Affected Systems:Siemens SIMATIC WinCC Open Architecture Description:--------------------------------------------------------------------------------Bugtraq id: 65339CVE (CAN) ID: CVE-2014-1696
Siemens SIMATIC WinCC is a SCADA and HMI system for monitoring control and data collection.
Earlier than siemens simatic WinCC OA 3.12 P002, siemens simatic WinCC uses a weak password hash algorithm, which has a security vulnerabilit
Release date:Updated on:
Affected Systems:ICONICS GENESIS32 8.xDescription:--------------------------------------------------------------------------------Bugtraq id: 65706CVE (CAN) ID: CVE-2014-0758
ICONICS GENESIS32 is a Scada product used for commercial facilities, energy, food, agriculture, medical care, and water conservancy.
The ActiveX controls used by GENESIS32 8.0, 8.02, 8.04, 8.05characters of genlaunch.htm files are insecure. Remote atta
data file is updated. You can query historical sample values or historical interpolation data of real-time production data from this database.
Relational databases design data tables based on the relationship between entities.
(2)System Stability
Because real-time Databases record production-related data and time-related data, they must be able to run stably for a long time. Otherwise, data loss may occur. Currently, some real-time databases already have the data caching function. When the comm
Release date:Updated on:
Affected Systems:Sielcosistemi sielco sistemi Winlog Lite 2.07.14Description:--------------------------------------------------------------------------------Bugtraq id: 53811
Winlog Lite is an entry-level SCADA/HMI software Winlog Pro provided by Sielco Sistemi. It evaluates the possibility and simplicity of software packages and is also a solution for creating small management applications.
Winlog Lite has a remote buffer ove
Release date:Updated on: 2012-08-01
Affected Systems:Wellintech KingView 65.30.2010.18018Wellintech KingView 65.30.17249Wellintech King View 6.53Description:--------------------------------------------------------------------------------Bugtraq id: 54729
Kingview is the first SCADA product for monitoring and controlling automation devices and processes for Small and Medium-sized projects launched by the Asian Control Corporation.
WellinTech KingVie
Siemens SIMATIC WinCC Information Leakage Vulnerability (CVE-2016-5744)Siemens SIMATIC WinCC Information Leakage Vulnerability (CVE-2016-5744)
Release date:Updated on:Affected Systems:
Siemens SIMATIC WinCC Siemens SIMATIC windows CC 7.2
Description:
CVE (CAN) ID: CVE-2016-5744Siemens SIMATIC WinCC is a SCADA and HMI system for monitoring control and data collection.Siemens SIMATIC WinCC Link: http://www.siemens.com/cert/pool/cert/siemens_securi
Release date:Updated on: 2013-07-30
Affected Systems:Ge-ip Proficy CIMPLICITYDescription:--------------------------------------------------------------------------------Bugtraq id: 61469CVE (CAN) ID: CVE-2013-2785
GE Proficy CIMPLICITY is a client/server business visualization and control solution.
The CimWebServer component of GE Proficy CIMPLICITY has a remote code execution vulnerability. This vulnerability occurs because the user input boundary check in the szOptions field is invalid, cau
Release date:Updated on:
Affected Systems:Schneider Electric Vijeo Citect 7.20Description:--------------------------------------------------------------------------------Bugtraq id: 61598
Schneider Electric Group provides products and services for energy and infrastructure, industry, data centers and networks, buildings and residential areas.
Vijeo Citect 7.20, CitectSCADA 7.20, and PowerLogic SCADA 7.20 have security vulnerabilities. Local attacke
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.