Discover installshield installation information, include the articles, news, trends, analysis and practical advice about installshield installation information on alibabacloud.com
installshield| program I am now doing ASP installation program, so that users can easily use. The InstallShield version I use is InstallShield Professional-standard Edition6.3.
I have not used this stuff, the questions are as follows:
Question One
Copy package work is done with Project wizard-generated script. However
Preface:
For some InstallShield users or enterprises, in addition to the installation of the package interface with the default installation dialog box, sometimes may need to use the installation interface of the platform for product or corporate image promotion, Custom Installatio
Preface:
For some InstallShield users or enterprises, in addition to the installation of the package interface with the default installation dialog box, sometimes may need to use the installation interface of the platform for product or corporate image promotion, Custom Installati
Objective: To achieve this without re-compiling the installation packageInstallShieldInstallationProgramFile update
Environment:Is2009
Steps:
1.From the installation directory. \ SystemExtractIscab.exe,Istools. dll,Mediabuild40.dllFile, copy them to the self-built folder, for example, copyD: \ testDirectory.
2.Copy the installation package to be modified
The "1152: error extracting" error may occur in the Installation File Created by InstallShield. How can this problem be solved?
If an English operating system is installed, this problem may not occur, but it is a Chinese or Korean operating system. This problem is likely to occur, whether it is XP, 2 K, or server.
Why is this error?
The answer is that some special characters (such as copyright symbols) m
installshield| program//////////////////////////////////////////////////////////////////////////////
//
Function:onfirstuiafter
//
Event:firstuiafter event is sent after file transfer, when installation
is run for the "the" "the" given machine. In this event handler
Installation usually displays UI that would inform end user
The installshield| program version 6.3 seems to be driven by events:
//////////////////////////////////////////////////////////////////////////////
//
Function: Onfirstuibefore
//
Event: Firstuibefore event is sent when installation was run for the
Time on given machine. In the handler installation usually displays
UI allowing end user to specify
installshield| program//////////////////////////////////////////////////////////////////////////////
//
Function:onfirstuiafter
//
Event:firstuiafter event is sent after file transfer, when installation
is run for the "the" "the" given machine. In this event handler
Installation usually displays UI that would inform end user
Tags: des blog, http OS, Io file, arOriginal article: InstallShield sets feature to a required status, that is, the installation statusPrevious Article: solved the problem of residual target folders during uninstallation.In installation designer --> organization --> features, select the feature to be set. In the attribute column on the right, select "yes" for req
This week, we need to install an installation package for a project created in the previous period. The project is in the C/S structure and the client uses the "installation project" that comes with vs2003, it also meets the requirements-you can change the server address pointed to by the client during installation.
The server is troublesome, because there is a
Original post address: http://www.delphibbs.com/delphibbs/dispq.asp? Lid = 1048756
Our company's software is packaged together with sqlserver and has a protocol with Microsoft.
I wrote
Program To control the installation of sqlserver7. After trying for a year, it can basically be installed, no major problems
In fact, it is done by referring to the installation instructions of online help.
The following is
Tags: blog http OS file for Ar code htmlOriginal article: Why the installation package created by Installshield is restarted and the SolutionSometimes, after you uninstall the installation package program created by InstallShield, you will be prompted to restart your computer to complete all uninstallation. The followi
Previous Article: solved the problem of residual target folders during uninstallation.
In installation designer --> organization --> features, select the feature to be set. In the attribute column on the right, select "yes" for required. During installation, the feature is selected, the check box is gray and the status cannot be changed. That is, the feature cannot be selected and will be installed on th
recently in the study using Instanllshield to make the installation package, and to create data, to master the InstallShield in the launchappandwait functionThis function is the effect of running other programs at run time, and can pass parameters and whether to run silently. For example:szscriptpath =supportdir+ "\\CREATEORACLEUSER. SQL ";longpathtoquote (Szscriptpath, TRUE);szCmdLine = DBUSER + "/" + Dbpa
installshield| program///////////////////////////////////////////////////////////////////////////////
//
Function:onmaintuiafter
//
Event:maintuiafter event is sent after file transfer, as end user runs
Installation that has already been installed on the machine. Usually
This happens through Add/remove Programs applet.
In the handler installation usually displays
installshield| program///////////////////////////////////////////////////////////////////////////////
//
Function:onmaintuiafter
//
Event:maintuiafter event is sent after file transfer, as end user runs
Installation that has already been installed on the machine. Usually
This happens through Add/remove Programs applet.
In the handler installation usually displays
"Resolve self-extracting executable silent installation failed(log file content: [responseresult]resultcode=-5 is file does not exist):Method 1.setup.exe-s-f1 "path to the response file"//Specify the ISS path.Method 2. ADD The response file (that is, ISS files) to the Disk1 folder under Advanced Files in the Support files/billboards view.Then build.This method is to package the ISS file directly into EXE to solve the problem of unable to find response
Recently, a copy of the directory or file (especially binary files such as Dll\ocx\exe) that was added during the development process was found to fail during the upgrade installation. After a week of research, the perfect solution: for a new file or directory, put in a fresh component, and this component need to be associated to the original feature sub-feature (new), the child feature to be set to the Require property is Yes, and set a KEYF ile in t
Recently in the study using Instanllshield to make the installation package, and to create data, to master the InstallShield in the launchappandwait function This function is the effect of running other programs at run time, and can pass parameters and whether to run silently. For example:Szscriptpath =supportdir+ "\\CREATEORACLEUSER. SQL ";Longpathtoquote (Szscriptpath, TRUE);szCmdLine = DBUSER + "/" + Db
The so-called "silent" means that no prompt box or UI interface is displayed during the installation/uninstall process, and the whole process is completed silently.
Install/uninstall InstallShield silently:*. EXE/s or *. EXE/s
Don't underestimate the differences in Case sensitivity. In actual use, I found that the lower-case s does not prompt the dialog box, but there is a progress bar, and the upper-ca
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.