Install mirror E 11g on Solaris 10 iSCSI 64 bit
I went to a client yesterday to install the 11g database, and made a record of the entire installation process and encountered problems. Because the customer cannot remotely connect to the server using his own machine or copy any files through a USB flash drive or a mobile hard disk, some records cannot be detailed and can only be roughly written by memory.HOST: SUN Netra T4-1 M4000CPU: 8 core 2.85GHz me
Microsoft ISCSI software Target supports snapshot management, which allows you to manually create snapshots, snapshot task schedules, snapshot rollback, and so on.The iSCSI target and device mappings are configured first, and the client maps the device to locally allocated disk space through the initiator program.For the sake of experimentation, we copy some files in the mapped e-disk to make a snapshot ref
We have built a domain and deployed Windows Server 2008 R2 on two computers in the domain. In this article, we're going to have Windows Storage Server 2008 perform another function in addition to being a domain controller: to act as a shared storage for the cluster. Windows Server 2008 R2 can support dynamic migration of virtual machines, and the key is to have the virtual machines stored on a cluster shared volume. Cluster Shared volumes refer to a single storage device that is shared by each n
For storing SQL databases1. Installation Services2. Restart the computer after the installation is complete. Add this feature to configure the computer, if it is a formal server, the kind of server can not be shut down too long, please use caution.After reboot, see the file and Storage service, click to enter3. See iSCSI and click on the New Disk Wizard4. Select the disk.5. Enter a name and description6. Set the disk size7. New, Next8. Set the disk na
1 Introduction
SAN is a private network and the backend of a network server group. It can be connected to a high-speed private network using storage protocols such as fiber channel or iSCSI, so that network servers can be directly connected to multiple storage devices. SAN can achieve many-to-many connections between network servers and storage devices. In addition, this connection is a local high-speed connection. The advantages of the SAN architectu
Software:Microsoft ISCSI Software Target 3.3After download, unpack the package as follows:Install the official description of the target end is the server only support Windows Server R2, Windows Server R2 SP1 operating system.The installation steps are the next step and the next method.To configure the destination end (target)To set up authentication:============= Client Settings ============The first run will have the following tips:Providing storage
Iscsi provides security settings. iSCSI has good advantages in security management. You can use "host" and "user" to allow or reject access settings.
After the installation is complete, the following example will be generated by default: "Only 172.16.7.120 this initiator is allowed" and "reject all" Settings
/Etc/initiators. allow content, the last line allows 172.16.7.120 (the other three lines are # A
, what the company needs to do is stabilize the existing architecture, or look long and deploy new technology.
Citrix and DataCore Solutions
Radford knows what Washington archives needs: An IT architecture with replication, redundancy, disaster recovery, and good flexibility, and its costs to be within acceptable limits.
As a partner for Citrix and DataCore, Moose Logic knows how to design and deploy a reliable, scalable, high-performance business solution.
"We get a shared storage environme
You need to modify the corresponding values according to your environment.Cattestiscsi.sh#!/bin/bashworkd= '/home/vdbench050406 ' sdnum=1hdnum=1threadnum=8seekpct=100rdpct= 70xfersize=8kiorate=maxelapse=68400maxdata=1000ginterval=5name=multihost-${xfersize}-${seekpct}.fileecho "Hd=default,vdbench=${workd},user=root,shell=ssh" >>${name}echo "hd=hd1,system=" >>${name}echo "hd=hd2,system=" >>${name} #echo "hd=hd3,system=" >>${name} #echo "hd=hd4,system=" >>${name} #echo "hd=hd5,system=" >>${nam
The first two chapters mainly introduce how to set up iSCSI storage in Openfiler and how to mount two Linux iscsi devices. This chapter is about the configuration of Oracle ASM and the installation of clusterware.The hosts file of my linux host is as follows:
Each host requires two NICs, And the 192.168.202.X network segment provides external services. The 192.168.9.X network segment serves as the heartbea
Install CentOS6.0 on Citrix XenServer and configure iSCSI service 1. mount xe-tool and install # mkdir/media/cdrom # chmod 777/media/cdrom # mount/dev/cdrom/media/cdrom #/media/cdrom/Linux/install. sh... # umount/media/cdrom # reboot 2. mount the CentOS installation disc. The update source is the mounted ISO file www.2cto.com # mount/dev/cdrom/media/cdrom # cd/etc/yum. repo. d/cancel two sources # mv CentOS-Base.repo CentOS-Base.repo.bak # mv CentOS-D
address, open storage, and click zfsvolumemanager.
Open the create zfs interface, add the relevant hard disk, add addvolume, select the generated zfs, and click createzvol
Generate a volume. Allocable size. 650) this. width = 650; "title =" 1.png" alt = "164018935.png" src =" http://www.bkjia.com/uploads/allimg/131228/04503A093-0.png "/>
4. Click services --- iscsi.
Generation in turn: ADinitators --- can limit the associated network 650) this. width
1. Discovery of iSCSI storage devicesIscsiadm-m discovery-t sendtargets-p 192.168.1.1:32602. Discovery Record ItemISCSIADM-M node3. Log in to the nodeIscsiadm-m node-t iqn.2001-05.com.equallogic:0-fe83b6-ac96160c3-c1e22d6fd8c56678-test-p 192.168.1.1:3260-l4. Discovery of Local DiskFdisk-l5. Partition the disk and mount the local directory.Fdisk/dev/sdbMkfs.ext4/dev/sdb1Mount/dev/sdb1/backup6. Log out of the nodeIscsiadm-m node-t iqn.2001-05.com.equall
theory that can be used is less than the actual one.LUNsYou can also connect multiple logical devices (such as disks, volume groups, and so on) under each SCSI target device (target), so that each logical device has a LUN (Logical Unit number) to identify itself, in order for the system to differentiate between each logical device. Each SCSI ID has a maximum of 32 LUNs, which starts from 0 by default (although 0 is occupied), and each LUN corresponds to a logical device.SCSI Communication Model
Under the build tab of the project, double-click default, select C/C ++ compiler, and change tool to the path of the executable file of the cross compiler to be used, for example, if my cross compiler is placed in C:/tornado/target/config/rtems-4.8-mingw/bin/iSCSI-RTEMS-GCC, the tool is changed to the preceding directory, and the assembler and the linker can be modified in the same way.
For compilation options, if you want to support // annotation, y
The services you see in the service start and do not start,and confirm it in the console.As shown in the following:650) this.width=650; "title=" Openfiler-2015-08-01-21-27-29.png "src=" http://s3.51cto.com/wyfs02/M01/70/BF/ Wkiol1w8y5wabj9kaaio6r2zm38660.jpg "alt=" Wkiol1w8y5wabj9kaaio6r2zm38660.jpg "/>This article is from the "halfway It People" blog, so be sure to keep this source http://ccie23951.blog.51cto.com/829845/1680874Unable to add target IQN workaround when creating an
1: Modify Mac OS system time2:mac OS system via proxy InternetVMware 12 Install Mac OS X 10.10 virtual machine Optimization TipsVirtual video card mishap, so it must be optimized to use, the principle of optimization is able to streamline the simplification, can close the effect on the off, do not duang, the following are some optimization settings:1. Remove Dash
Before I wrote a MAC address plus minus 1 conversion of the article, there are some less comprehensive, here I re-a blog to explain.The real address of the Mac should be: ADCF4D5FD3CF, this, not AD:CF:4D:5F:D3:CF, this is the artificial colon, in order to look convenient;How about the MAC address minus 1? In fact, since the M
Why do you want to bind IP? Can you specify the IP can not be on the network? The reason to bind IP is because he will change the IP. For example, I am the IP on this computer is 192.168.1.11 this IP has been done in the firewall above the setting can not be online, but if I know that there is an IP is 192.168.1.30 IP can surf the internet, then I will not change the 192.168.1.11 replaced by 192.168.1.30 can be online?So the binding IP is to prevent him from changing IP. Because the
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.