you don't have to go to the data center to view it.
----------------------------------------------------------------------------
Physical Hard Disk:
First install the MegaRAID management tool provided by the server provider. You can download it from the official website:
/Opt/MegaRAID/MegaCli/MegaCli64-LDInfo-Lall-aALL
View raid level and detailed raid Information
/Opt/
multicolumn secondary indexes. At the end of the test, TOKUDB's insertion rate remained at 14,532 Inserts/second whereas InnoDB had dropped to 1,607 ins Erts/second. That's a difference of over 9x.Platform:centos 5.6; 2x Xeon L5520; 72GB RAM; LSI MegaRAID 9285; 2x 256GB Samsung 830 in RAID0highest COMPRESSIONCompression is an always-on feature of Tokudb. We tested InnoDB compression with the values of key_block_size (4k and 8k) and with compression d
The company has a Dell R720 server, want to install Xen, the result of loading when asked me to select the disk, it appears that the disk RAID does not recognize the problem. Find Dell official for detailed model,megaraid SAS 9265-8i is LSI's product, go to LSI official website http://www.lsi.com China Station: http://www.avagotech.cn /support/download-search Download
Understand, first go to Baidu search for this raid information, understand,
Install necessary software yuminstall-yMegaCliLib_Utils to get deviceid/opt/MegaRAID/MegaCli/MegaCli64-LdPdInfo-aALL | grep-B30 #39; SolidStateDevice #39; | grep #39; DeviceId #39; what I get here is:
Install necessary software
yum install -y MegaCli Lib_Utils
Obtain the device id.
/opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aALL | grep -B 30 'Solid State Device' | grep 'Device Id'
What I get here is 1.
feature is enabled to prevent the write Back and no RAID card battery situation, the system power loss results in the final, considering the IDC room situation we have turned on the battery discharge state also forced to open the cache policy to solve the short-time on the write performance of the excessive gap to see if the current mode, the following is the write ThrougForced Open method/opt/megaraid/megacli/megacli64-ldsetprop Cachedbadbbu-lall-aa
inside the chip. 0x0 ~ 0x0f FFFF is Boot memory, 0x10 0000 to 0x10 7fff is Rom. 0x20 0000 ~ 0x20 0fff is sram0, 0x30 0000 ~ 0x30 0fff is sram1. What is Boot memory? Boot memory is an idle address. You can map sram0 and Rom to this address, that is, use the control register to select ROM and sram0 to map to the boot memory location. If you access the boot memory address, that is, the ROM or sram0 address mapped to this location. For example, if the boot memory is mapped to sram0, the access loca
: Enabled
As shown above, the hard disk model is SanDisk SD6SB1M128G1022I and the capacity is 128 GB.
Ii. Disk Array RAID Mode
If the machine has a disk array, an error will be reported when running the above command, and the disk information you need is not obtained. You can use the MegaCli command
The MegaCli command system is not provided and requires additional downloads,
:
Http://www.lsi.com/downloads/Public/RAID%20Controllers/RAID%20Controllers%20Common%20Files/8.07.14_MegaCLI.zip
Decomp
View ssd Service Life in CentOS
Install necessary software
Yum install-y MegaCli Lib_Utils
Obtain the device id.
/Opt/MegaRAID/MegaCli/MegaCli64-LdPdInfo-aALL | grep-B 30 'solid State devic' | grep 'device id'
What I get here is 1. When smartctl is used below, 1
Smartctl-a-d sat + megaraid, 1/dev/sdc | grep Media_Wearout_Indicator
Wear Levelling Count (average number of particle writes): The last col
In the past few days, the write policy of the RAID card is switched back to WT from WB. If "Learn cycle" occurs during business peaks, it will seriously affect the performance of the database. After the problem is solved, sort out your understanding of these problems. I will not describe the megacli command set I have used. There are a lot of information about it on the Internet. We recommend related articles by Tan and ye from Chinese documents.
I will explain the problems related to the RAID c
1 IntroductionThe RAID card battery on the server, referred to as the BBU, is a very important component, it has a large impact on the I/O performance of the disk, but the general Bbu power can only be used for 90 days, the system will automatically charge it after the power is exhausted, but it usually takes a few hours to charge, during charging, The cache status of the RAID card is in write through, i.e. without the caching feature. So in order to ensure that the server is in normal operation
8.00.48_Linux_MegaCLI.zipunzip MegaCliLin.ziprpm2cpio Lib_Utils-1.00-09.noarch.rpm | cpio -idmvrpm2cpio MegaCli-8.00.48-1.i386.rpm | cpio -idmvcpopt/MegaRAID/MegaCli/MegaCli64 /sbin/cp opt/MegaRAID/MegaCli/MegaCli/sbin/
MEGACLI not only can query the status of the raid, but also set the state of the raid, so it is better for the administrator to master, so that the installation is complete.The f
), they will always take precedence over local hard disk detection, which will cause local drive letters to be changed.
Follow the usual steps to install the OS. after the system is installed, insert the RAID or scsicard back to the host. The system will automatically discover new devices upon next restart. However, to ensure that the device can be automatically started during each system boot, you still need to do the following two steps:
A. Edit the/etc/modules. conf file and add the fol
The article itself I do not make too many changes, here I put myself in the installation of the difficulties encountered with everyone to mention.1. Where to download?First of all, according to the path in the article has not been downloaded to the corresponding file, here we go to Http://www.lsi.com's website to search, try a variety of combinationsFinally with Linux_cli.zip in the search bar search for the corresponding results, find the Linux version, download can.I also uploaded the file to
Objective:Dell Next-generation 13G server R630, R730, T430 .... such as the product has a RAID card does not support the Redhat 5/centos version of the operating system, this article will take the T430 server as an example to demonstrate the method of installing the REDHAT5 version.First, drive download1 Dell 13G service organ network array driver not supported redhat5 system, because dell The array card uses lsi The chip, so here to Span lang= "en-us" xml:lang= "en-US" >lsi Dow
array raid modeIf the machine has a disk array, then running the above command will error, not get the disk information you want. You can use the MEGACLI commandMEGACLI command system does not own, need additional download,:Http://www.lsi.com/downloads/Public/RAID%20Controllers/RAID%20Controllers%20Common%20Files/8.07.14_MegaCLI.zipUnzip after download,Unzip Csa1.5-megacli_rel80571.zipCD Megacli/megacli_linuxRPM-IVH megacli-8.05.71-1.noarch.rpmInstallation CompleteLn-s/opt/
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.