megaraid

Learn about megaraid, we have the largest and most updated megaraid information on alibabacloud.com

How to view the hard drive brand model and other details, CentOS brand model

information on the right side of the User Capacity is the actual size of the hard disk. It also indicates that the machine has no disk array. If the machine has a disk array, run the preceding command to obtain the following results: Vendor: DELLProduct: PERC H310Revision: 2.12User Capacity: 999,653,638,144 bytes [999 GB]Logical block size: 512 bytesLogical Unit id: 0x6b083fe0e9aa11111cf09480020.aee5Serial number: 00e5ae40048094f01c1111aae9e03f08Device type: diskLocal Time is: Fri Jul 3 15:39:0

How CentOS can view specific information such as the hard drive brand model

Unit ID: NBS P 0x6b083fe0e9aa11111cf094800440aee5 Serial Number: 00E5AE40048094F01C1111AAE9E03F08 Device Type: disk Local time is: nbsp fri Jul 3 15:39:02 CST Device does not support SMART Error Counter Logging not supported The vendor and product here are actually information about the disk array card, not the disk information.At this point, you can install the Smart tool, instructions for yum install smartmontools, enter the command and return. After entering the command:

More than 2T of disk formatting

Fdisk can only be used for less than 2T disks, larger than 2T disks need to use the parted tool partitionFirst, enter the parted1, Parted/dev/sdb2. (parted) Print freeModel:lsi megaraid 8708ELP (SCSI)Disk/dev/sdb:7438gbSector size (logical/physical): 512b/512bPartition TABLE:GPTNumber Start End Size File system Name Flags17.4kB 7438GB 7438GB Free Space3, (parted) Mklabel GPT4, (parted) MkpartPartition name? []? DataFile system type? [Ext2]? Ext3Start?

Freebsd compiler kernel

dc315u Adapters #device adv # AdvanSys SCSI adapters#device ADW # AdvanSys wide SCSI adapters#device AHA # Adaptec 154x SCSI Adapters#device AIC # Adaptec 15[012]x SCSI adapters, aic-6[23]60.#device BT # Buslogic/mylex multimaster SCSI Adapters#device NCV # NCR 53c500#device NSP # workbit Ninja SCSI-3#device STG # TMC 18C30/18C50 # SCSI Peripherals #device scbus# SCSI bus (required for SCSI) #device ch nbsp;# SCSI Media changers #device da# Direct Access (disks) #device sa# sequential Acce

Details of Linux system data landing

disk media in a timely manner, so there is no charge/discharge problem. Read/write ratio: The HP Smart Array provides the difference between read and write to the cache (Accelerator Ratio),HPACUCLI Ctrl all show config Detail|grep ' Accelerator Ratio 'Accelerator ratio:25% read/75% WriteThis allows you to set the ratio of cache read and buffer write caches to the actual application. Turn on direct IO In order to enable the upper device to use direct IO to bypass the

DELL 5i/6i Array Card Quick Setup Graphics tutorial

channel SAS RAID card, up to 8 SAS interface or SATA interface server hard drive, LSI Logic 1068 SAS control chip, IOP333 coprocessor, 512M ddrii REG-ECC Cache, With a cache battery, supports a variety of array modes: 0, 1, 5, 10, native Pci-e 8X interface, compatible PCI-E 16X slots 3GB/S 8-Port internal SAS RAID adapter As the first market-driven 8-port serial scsi (SAS) RAID solution, 5/I provides advanced fault-tolerant performance for any combination of SAS drives, SATA II drives, or two

Installation of LSI MEGACLI Disk array management tool under Ubuntu

the server with Ubuntu system is turned on, but to see the status of the server RAID10, the LSI megacli Disk array management tool can be viewed by the following steps:1. Add Update sourcesudo vim/etc/apt/sources.list//add at the end Deb Http://hwraid.le-vert.net/ubuntu Precise Main sudo apt-get update//updating sourceNote: Some warnings can be ignored, but if you are prompted with a GPG error, you need to add a certificate by following this command:sudo wget-o-Http://

[Turn]linux system Monitoring, diagnostic tool IO wait

)You can see that the utilization of SDB in both drives is already 100%, there is a serious IO bottleneck, and the next step is to find out which process is reading and writing data to this hard drive.2.3 IotopBased on the results of iotop, we quickly locate the problem of the flume process, resulting in a lot of IO wait.But at the beginning I have said that the machine configuration in the cluster, the deployment of the program is the same as rsync, is the hard drive broken?This has to find the

[Turn]linux system Monitoring, diagnostic tool IO wait

SDB in both drives is already 100%, there is a serious IO bottleneck, and the next step is to find out which process is reading and writing data to this hard drive.2.3 IotopTechnology sharingBased on the results of iotop, we quickly locate the problem of the flume process, resulting in a lot of IO wait.But at the beginning I have said that the machine configuration in the cluster, the deployment of the program is the same as rsync, is the hard drive broken?This has to find the operation of the

VMware ESXi View network card, RAID card driver

protected]:~] ethtool-i vmnic0driver:igbversion:5.0.5.1firmware-version:1.63, 0x80000dbdbus-info:0000:01:00.0[[email protected]:~] Ethtool-i VMNIC7DRIVER:BNX2XVERSION:1.78.80.V60.12FIRMWARE-VERSION:BC 7.8.55bus-info:0000:11:00.1Gets the type of driver currently used by the host bus adapter[Email protected]:~] esxcfg-scsidevs-avmhba0 lsi_mr3 link-n/a sas.500605b00cbce9e0 (0000: 07:00.0) LSI megaraid SAS Invader Controllervmhba32 iscsi_vmk online iqn.1

Linux MEGACLI tool view RAID disk array status

The new version of MEGACLI-1.01.24-0.I386.RPM installs the program under/OPT and can customize the installation directory, for example: rpm–relocate/opt/=/usr/sbin/-I megacli-1.01.24-0.i386.rpm to replace the installation directory/opt into/usr/sbin. Download Address: Http://www.lsi.com/support/downloads/megaraid/miscellaneous/linux/Linux_MegaCLI_1.01.24.zip I introduce here to install under/OPT.1. First introduce the Linux system itself to viewSoftwa

Recoveryware One-click Recovery system Download _ Common Tools

.). Perform user-defined Third-party applications at the front or back of the startup to complete additional information interaction, management diagnostics, etc. Merge user-specified registry configuration to WinPE environment at startup to facilitate modification of system options and add configuration information (for example, adding system services and input methods, importing custom advanced tool configuration information, and so on). Complete Driver Support : Support USB 2.0 ma

A closer look at InnoDB data Drop chart MYSQL expert Hatemysql

and write to the cache (Accelerator Ratio), HPACUCLI Ctrl all show config Detail|grep ' Accelerator Ratio ' Accelerator ratio:25% read/75% Write This allows you to set the ratio of cache read and buffer write caches to the actual application. Turn on direct IO In order to enable the upper device to use direct IO to bypass the raid card, the raid needs to be set to open Directio mode: /opt/megaraid/megacli/megacli64-ldsetprop-direct-im

Release: ClarkConnectBroadbandGateway3.1

Article title: Release Version: ClarkConnectBroadbandGateway3.1. Linux is a technology channel of the IT lab in China. Includes basic categories such as desktop applications, Linux system management, kernel research, embedded systems, and open source. The final version of ClarkConnect Broadband Gateway 3.1 has been released. we can learn from their release statement that ClarkConnect is built from the RPM Package of Red Hat Enterprise Linux 4, however, the release team made some changes accordi

Linux kernel version 2.6.14

Article title: Linux kernel version 2.6.14 is released. Linux is a technology channel of the IT lab in China. Includes basic categories such as desktop applications, Linux system management, kernel research, embedded systems, and open source. Linus Torvalds released the latest stable version of Linux kernel 2.6.14. This update introduces many notable changes in file systems and wireless LAN. File system Plan 9 9p remote file system FUSE (Filesystem in User space) RelayFS (high-sp

Server RAID Disk Bad Track repair practices

array is rebuilt and works normally. The system redetects and the error disappears. Note: The specific tools mentioned above are as follows: /Opt/MegaRAID/MegaCli/MegaCli64-PDList-aAll 650) this. width = 650; "src =" http://www.bkjia.com/uploads/allimg/140110/0424294137-2.jpg "style =" float: none; "title =" 8.jpg" alt = "wKioL1LKY_ziQNtrAADYQdYbcLg815.jpg"/> 650) this. width = 650; "src =" http://www.bkjia.com/uploads/allimg/140110/0424291E8-3.jpg "

View raid information for Dell server 192.168.66.235 with MEGACLI

Installing MEGACLI#cd/opt#rpm-IVH megacli-2.00.12-1.el5.x86_64.rpm#/opt/megaraid/megacli/megacli64-ldinfo-lall-aallLook, it's a 6-plate RAID5.650) this.width=650; "class=" Confluence-embedded-image "src=" http://wiki.tbox.me/download/attachments/10192235/ Clipboard.png?version=2modificationdate=1423560072000api=v2 "style=" margin:0px;padding:0px;border:0px ; "alt=" Clipboard.png?version=2modificationdate "/>View Disk Performance# iostat-d-x-k 1 10Disk

Array card cache battery charging and discharging problem

Disk array is a long-standing technology on the server, it is widely used by most server OEMs to make reasonable use of space and performance in different array modes to match the cost-effective disk array. Among them, LSI Company's MegaRAID SAS products are widely used in various brands (except HP) x86 servers.Why is there a cache?Array Card core technology consists of three parts: 1, Data stripe, 2, data redundancy, 3, cache. Where the cache is know

FTP Server transfer performance test RAID 1+0 Chapter

Frequency 3.3GHz Processor instruction Set MMX,SSE,SSE2,SSE3,Sse4.1,sse4.2,em64t,vt-x,aes,avx External bus Dmi5.0gt/s L1 Code Cache 4X32KB 8-Way Collection Association L1 Data Cache 4X32KB 4-Way Collection Association L2 Cache 4X256KB 8-Way Collection Association L3 Cache 8MB 16-Way Collection Association

Dell disk array control card (RAID card) megacli Common Management Command Summary

New version of megacli-1.01.24-0.i386.rpm (: Http://www.lsi.com/downloads/Public/MegaRAID Common Files/8.02.16_megacli.zip The package will install the program under/OPT, of course, you can also customize the installation directory, for example: RPM--relocate/opt/=/usr/sbin/-I megacli-1.01.24-0.i386.rpm (that is, the installation directory/opt replaced/usr/ Sbin). (There is a megacli file in the Linux folder with I386 RPM) related commands and their

Total Pages: 4 1 2 3 4 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.