Loadlibrary ("testocx. ocx") failed-the specified module cocould not be found

An error occurred while registering the ActiveX Space developed with VC ++. The following message is displayed when you register the space with regsvr32 testocx. ocx:Loadlibrary ("testocx. ocx") failed-the specified module cocould not be found View testocx. ocx with depends and find some files missing When I copy the corresponding files from the development machine to the test machine and depends again,

JSP Call OCX

1, configure the Tomcat and JDK environment, write a simple JSP, call OCX Control 2, OCX control needs to register From for notes (Wiz)

Flash9.ocx Load Error Resolution

Error | loading | resolution When browsing Web pages with IE, you often encounter flash9 plug-in loading errors. If you choose to continue, the CPU takes up to 90% or more seconds before the Web page shuts down automatically. If you turn off the Flash9.ocx, do not load, flash can not see. How to solve? Method One:Re-register the following DLL file, you point "start", "Run" on the desktop:regsvr32 Shdocvw.dllregsvr32 Shell32.dll (Note this command)reg

Vc6.0 creates OCX and calls it on the web.

1. Open vc6.0, create a project, and select "MFC ActiveX controlwizard". The default setting is as follows; 2. on the classview, you can see that there are mainly ** app \ ** CTRL \ ** progpage classes, and the interfaces are mainly implemented in ** ctrl, you can use the automation page of MFC classwizard (CTRL + W) to create interface functions; 3. The interface function is external, so pay attention to the parameter type definition. I generally use the lpctstr character, as shown in the f

OCX creates a cab package

Use \ windows \ system32 \ iexpress.exe. 1) Select "create new self extraction directive file" and click Next. 2) Select "create compressed files only (ActiveX instils)" and click Next. 3) Click Add, add the file (pcpos. ocx, pcpos. dll, Comm. dll, tcpclnt. dll), and click Next. 4) Click Browse and enter the storage address of the. cab file (including the obtained file name). Here testcab. Cab is selected and "store files using long file name in

Component mswinsck. OCX ' or one of its dependencies isn't correctly registered:a file is missing

__________________________________________________________Problem: The system popup prompts "missing Mswinsck.ocx", "No Mswinsck.ocx found" and so on.As shown in the following:Workaround:1, download Mswinsck.ocx.2, copy the file "Mswinsck.ocx" to the system directory.3, the system directory is generally: C:\WINNT\System32. 64-bit system for C:\Windows\SysWOW644. Finally click Start Menu--run--Enter regsvr32 mswinsck.ocx, enter to resolve the error prompt!mswinsck.ocx: http://download.csdn.net/de

How to troubleshoot an error when loading flash9.ocx

How can this problem be solved? Method 1:Register the following DLL files again. Click "start" and "run" on the desktop ":Regsvr32 shdocvw. dllRegsvr32 shell32.dll (note this command)Regsvr32 oleaut32.dllRegsvr32 actxprxy. dllRegsvr32 mshtml. dllRegsvr32 urlmon. dll Note: you do not need to enter the second command. After these commands are entered, restart Windows. If the command is invalid, re-enter the second command. Method 2:If an error occurs when you use the method to register reg

Javascript calls OCX to obtain string array parameters

// The OCX function implements variant myocx: returnstringarray () {variant varesult; variantinit ( varesult); varesult. vt = vt_variant | vt_array; cstring Item1 = l "Item1"; cstring item2 = l "item2"; safearraybound msab [1]; msab [0]. llbound = 0; msab [0]. celements = 2; varesult. parray = safearraycreate (vt_variant, 1, msab); longL = 0; variant vaitem1; vaitem1.vt = vt_bstr; vaitem1.bstrval = item1.allocsysstring (); safearrayputelement (varesul

Js+dll+ocx

(IDispatch)Com_interface_entry (IConnectionPointContainer)Com_interface_entry (IObjectWithSite)Com_interface_entry (IObjectSafety)//Release safety tipsEnd_com_map ()Begin_connection_point_map (Cznactivexatl)Connection_point_entry (__uuidof (_iznactivexatlevents))End_connection_point_map ()Declare_protect_final_construct ()HRESULT FinalConstruct (){return S_OK;}void FinalRelease (){Freeing resourcesFreeLibrary (hInstLib);}PublicSTDMETHOD (Zn_init) (char* appname, char* PIN, long* RC);STDMETHOD (

Jsp js MSCOMM32.OCX webpage transmits serial data

1. Install mscommsetup .exe on the local machine to register the MSCOMM32.OCX control locally. 2. After registration Run the following code to test JSP: When the JS bullet box is 3, it indicates that the control is successfully loaded and the program can send data to the port.

Win7 cannot run OCX control, error code 0x80040200

1. First of all, press the Win7 flagship computer keyboard win+r shortcut keys to open the computer's running window, in the Open Run window, we enter CMD and click Enter, so that we can open the Command Prompt window of the Win7 flagship computer, and of course you can simply click to open the Start menu, Enter CMD directly in the search window below, which can also be clicked into the command Prompt window. 2. In the Open Command Prompt window, we just need to enter regsvr32 xx.ocx and cl

Use DSO framer OCX + Excel in B/S to solve complicated report problems

In actual enterprise applications, it is easy to handle complicated reports. Because reports are generally relatively complex, it is inconvenient to use common forms + fields, how can we make it easier? We know that report data is usually

MFC ActiveX (OCX) Creation Technology

1. Set the initial widget size. First, we need to set the initial size of the control to its static size using the COleControl::SetInitialSize method. This should be done in your control's constructor like this://////////////////////////////////////

Register the OCX control in Delphi

This is my previous sectionCode.     Code highlighting produced by Actipro CodeHighlighter (freeware)http://www.CodeHighlighter.com/--> 1 Procedure Tform1.button1click (Sender: tobject ); 2   VaR 3 Ocxhand: thandle; 4 Regfunc:

Using a custom message in OCX

Custom messages cannot be defined in ATL as in MFC, because there is no concept of MSG map in standard ATL, and if you are doing ActiveX, you can msg to window, ATL provides macros of the BEGIN_MESSAGE_MAP category: First, define the message ID:

In Pb, can I convert a file into a PDF file by calling the PDF. ocx control? Urgent !!!

  1.download and install gs705w32.exe You can also download and install ghostscript7.07, but pb9 does not support gs8.0 and later versions! 2. For powerbuilder9.0 Add in system environment variable path The default installation path of gs705w3

Office OCX mspview. EXE mdivwctl. dll

C # Call the office2003 text recognition function Bool callocx (string filename, out string con) { Con = ""; Try { Modi. Document Doc = new Modi. Document (); Doc. Create (filename ); Doc. OCR (Modi. milanguages. milang_chinese_simplified, false,

The MFC dialog box in dll/OCX cannot handle the tab and enter keys.

The original Article is published in [http://community.csdn.net/expert/Topicview2.asp? Id = 3072485] Question about ActiveX controls in the tape window: How do I get the Enter key? Problem: Create an MFC ActiveX project, add a dialog box

In the MFC project environment, make ActiveX OCX to cancel the security prompt of IE browser

Add # pragma once in the next line of the xxxctrl. H (XXX is the project name) header file // ------- Add ---------------// Cancel IE Security Prompt# Include "objsafe. H"// --------- Add ---------------------------- And declare part of the

Using custom messages in OCX

You cannot define custom messages in ATL, as in MFC, because the concept of MSG map is not in standard ATL, and if you are doing ActiveX, you can give msg to Windows. ATL provides begin_message_map a class of macros: First, define the message ID:

Total Pages: 15 1 .... 6 7 8 9 10 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.