Analysis of crs-4000 errors in oracle11.2.0.4rac setup

AUs) ERROR: Voting file allocation failed for group VOTE Errors in file/g01/11 ggrid/app/11.2.0/grid/diag/asm/+ ASM1/trace/+ ASM1_ora_7321.trc: ORA-15303: Voting files cocould not be created in diskgroup VOTE due to small Allocation Unit size View the corresponding DM of the arbitration disk of the corresponding GRID # Multipath-ll SC _vote (360a980003830302d712b31686276736b) dm-11 NETAPP, LUN Size = 5.0G features = '4 queue_if_no_path pg_init_retri

Display of file modification time on NFS File System

The file modification time on the NFS file system displays the problem of Solaris + NetApp storage. The user's home directory is placed on NetApp and mounted to the local through autofs. You can use ls-l to view the touch file in your home directory. The mtime (modify time) column only displays the year, month, and day, but not the time. $ Touch file $ ls-l file-rw-r -- 1 user 0 Aug 25 2009 file after waiti

Netapp:data Ontap 7 mode and cluster mode

650) this.width=650; "Src=" Http://s5.51cto.com/wyfs02/M02/85/70/wKiom1ejQeXidaTPAABUAFY4deo986.png-wh_500x0-wm_3 -wmp_4-s_3390440057.png "title=" Capture.png "alt=" Wkiom1ejqexidatpaabuafy4deo986.png-wh_50 "/>The first data Ontap borrowed a lot of code from one of the earliest Open source Unix BSD NET/2, including the TCP/IP stack, boot code, device driver, and later data Ontap from other Open source Unix. As for the command-line interface, which was developed independently by

Air13 and Air13pro do not support Win7 installation instructions

1. Windows 7 is not supported on Skylake.This is because Intel removed the EHCI controller from the next-generation Skylake platform and changed it to the XHCI controller. The native Windows 7 system does not support the XHCI controller. Simply put, without EHCI, the USB interface cannot be identified when Windows 7 is installed on the Skylake platform. Then, you cannot use a USB flash drive, a mobile hard drive, or an external USB drive to install the Win7 system.2. Xiaomi Air13 and Air13pro ad

New changes in Linux3.19 kernel block layer, adding multi-queue block layers

Recently the latest Linux kernel has been released to LINUX-3.19-RC6, according to Linus's release note, about once again after a RC7 version can be formally released. The biggest change to the Linux 3.19 kernel at the block level is the addition of a multi-queue block layer to better support devices like NVMe that support the multi-queue mechanism. The so-called multi-queue mechanism is that in the case of multicore CPUs, different block layer submis

Samsung 960PRO Solid State hard Drive box drawing

. 960 PRO uses the PCIe gen.3 X4 channel interface to support NVME specifications for efficient use of high-speed PCIe bus, optimizing hardware and software configurations and taking full advantage of NVMe SSD technology. They also use the Samsung dynamic thermal protection technology to manage device temperatures at extreme workloads. This 960 PRO has adopted more technology and i

Business continuity practices

1. Count and collect the Server distribution and usage capacity of the netapp storage fas3240/2240. 2. Determine the migration sequence and prepare p2v Based on the operating system type windows2003/2008. 3. Deploy the vmwarevsphere esxi server 5.5 environment on 6 new blades, and migrate the original system collected in step 2 to p2v. The migration environment requires better ip links and ip Address resources. Link requirements: the blade service sup

New RAID technology

data is reconstructed and the new disk is added. 650) this. width = 650; "title =" 3.jpg" src = "http://www.bkjia.com/uploads/allimg/131228/0036234459-2.jpg"/> To solve the above problems, some solutions will consider some data migration operations to obtain the benefits of distributed free space, but will affect the system performance.NetApp DDP The new RAID technology of NetApp is also called the Dynamic Disk Pool, and it is similar to Quantum in m

Defects of online storage data compression technology

). With the duplicate data deletion technique, the data is not changed, but the copy data about 2-n times is deleted, and the indicator is inserted into a "main instance" of the data. A single instance can be treated as a duplicate data deletion. Traditional data deduplication is often not suitable for online software or primary storage software, because the algorithms needed to replicate data removal inevitably increase response time, which leads to increased costs. For example, popular de-dup

WinSrv2016 scale-out storage (SDS) [No shared storage]

of the cluster, including the file serverNew-cluster–name Storcluster–node stor1,stor2–nostorage-staticaddress 192.168.11.153650) this.width=650; "height=" "title=" clip_image009 "style=" margin:0px;border:0px;padding-top:0px; Padding-right:0px;padding-left:0px;background-image:none, "alt=" clip_image009 "src=" http://s3.51cto.com/wyfs02/ M01/79/9b/wkiom1awcb_quaogaacn5cepw2e398.png "border=" 0 "/>After the creation is complete, we can view the cluster network650) this.width=650; "height=" 113

What Is Nas?

familiar with these protocols, you do not have to worry about them. We will discuss them in future articles. Of course, the NAS mentioned above cannot be sold. Most enterprises choose NAs from companies such as EMC and netapp because they have features that are hard to implement on common file servers. First, let's give a brief introduction. Girls should polish their eyes to see how different things are from ordinary it guys. I. High Performance. If

"Go" end to end FCoE get breakthrough still need to wait for switch support

End to end FCoE get breakthrough still need to wait for switch support VMware has certified an End-to-end FCOE connectivity solution for Cisco and NetApp, but this does not mean that new markets are emerging because core switches still do not support transmission of FCOE information. Only the overhead switch (top-of-rack-switches) (tors) can transmit FCoE information.FCoE refers to Ethernet Fibre Channel, which inserts fibre Channel information into

Facebook stores 6.5 billion-photo storage frames

haystack did not explicitly indicate that it has entered the production environment in webcast. If the description is wrong, you are welcome to correct it. Facebook's storage architecture needs to deal with two things: Read and write. We will observe separately. Write: When a user needs to upload a photo, that is, a write to the Facebook store, Facebook assigns an upload server to work. The upload server processes the uploaded photos, and each photo is stored according to the 4~5 s

VMware mounts shared storage----NFS v4.1

1 Create a domain account 1.1 create an NFS dedicated domain account and configure the Account DES encryption type. 1.2 Permissions granted to account Domain Admin 2 Configuring SVM 2.1 to create SVM and root volumes on NetApp >vserver create-vserver nfs-rootvolume nfs_root-aggregate aggr1-rootvolume-security-style unix-language C.UTF-8-S Napshot-policy default-is-repository false-ipspace Default

Create a Linux & amp; Windows & amp; GParted Live & amp; macOS in one to maintain the U disk, making it easier to reinstall the system.

put it in the last partition. Let me introduce aomei pe. Many people may have used PE systems in China, and there are many problems. For example, many of them do not support NVME hard disks, so they cannot back up SSDS. Some unscrupulous authors may also carry private goods and secretly change the home page of the Computer Browser, automatically installs anti-virus software for a digital company. Another problem is ugly. Even the best "micro-PE" that

A probe into the Nutanix hyper-fusion system

of the data service and restore the data through distributed data redundancy to ensure the reliability of the data. BecauseNutanixThe data management method of the storage pool is adopted, so that the whole systemController VMcan be combined to recover data for the fault disk, so that the data can be recovered in a very short period of time, ensuring the reliability of the data. This idea and Huawei'sRAID2.0are essentially the same. JustNutanixAdoptErasure CodeData redundancy level or multiple

How to upgrade the memory and hard disk of Air13, Air12, and Air13pro

Solution:Tip: The content of this article is intended for your learning and reference. Lenovo does not recommend that you expand, upgrade, or replace hardware devices on your own. Such operations are risky. If you have the above requirements, we suggest you contact the nearest Lenovo service outlets for support from professionals.Small New Air13:Memory upgrade: the on-board memory cannot be upgraded.Hard disk upgrade: only one M.2 (NGFF) interface can be used to connect to the SSD. Both the SATA

Three key points for SSD Solid State Drive

the 500mb/s! 2, physical characteristics, low power consumption, no noise, vibration, low heat, small size, operating temperature range. Solid state drives do not have mechanical motors and fans, with a noise value of 0 decibels at work. The solid-state hard disk based on flash memory has lower energy consumption and calorific value under working state. There is no mechanical moving parts, no mechanical failure, no fear of collision, shock, vibration. Most solid-state drives can work in-10~70

Windows Server 2016-store new features

This chapter introduces new features for storage in Windows Server 2016, as follows:1. Storage Spaces Direct:Storage Spaces Direct allows you to build high-availability and scalable storage by using servers that have local storage. This feature simplifies the deployment and management of software-defined storage systems and allows new disk devices, such as SATA SSDs and NVMe disk devices, to be used without the use of shared disks in the previously cl

Difference between u.2 and m.2 interface solid-state drives

motherboard The M.2 interface can support both PCI-E channel and SATA, in which the former is easier to improve speed, theoretical bandwidth 10Gbps, it can be said that it also broke through the SATA interface theory transmission bottleneck. Today's m.2 interface to the PCI-E 3.0 x4 channel, the theoretical bandwidth reached 32Gbps, compared to the previous level of a lot of improvement, which also allows the SSD performance potential increased significantly. In addition, the interface SSD als

Total Pages: 15 1 .... 5 6 7 8 9 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.