Several methods to check whether the currently running LINUX is in the VM or on the physical machine

: $ cat/proc/scsi/scsiAttached devices: Host: scsi6 Channel: 03 Id: 00 Lun: 00 Vendor: HP Model: P410 Rev: 5.14 Type: raid ansi scsi revision: 05 Host: scsi6 Channel: 00 Id: 00 Lun: 00 Vendor: HP Model: logical volume Rev: 5.14 Type: Direct-Access $ cat/proc/scsi/scsiAttached devices: Host: scsi1 Channel: 00 Id: 00 Lun: 00 Vendor: NECVMWar Model: VMware IDE CDR10 Rev: 1.00 Type: CD-ROM ansi scsi revision: 05 Host: scsichannel: 00 Id: 00 Lun: 00 Vendor: VMware Model: Virtual disk Rev: 1.0 Type: D

KVM Introduction (3): I/O full virtualization and quasi-virtualization [KVM I/O QEMU Full-virtualizaiton para-virtualization]

Learn about KVM in a series of articles: (1) Introduction and Installation (2) CPU and memory virtualization (3) I/O QEMU full virtualization and quasi-virtualization (Para-virtulizaiton) (4) I/O pci/pcie Device Direct Assignment and SR-Iov (5) Libvirt Introduction (6) Nova manages QEMU/KVM virtual machine via Libvirt (7) Snapshot (snapshot) (8) Migration (migration) In QEMU/KVM, the devices that the client ca

How does the 4G memory become 2G

sy id wa st 0 0 92 53080 8228 1659048 0 0 679 194 967 2 5 89 4 0 1 0 92 51716 8244 1661008 0 0 64 4618 2 2 95 0 0 2 0 92 61664 8048 1649820 0 0 0 16 4329 10 18 71 1 0 1 0 92 60424 8064 1651540 0 0 2332 4587 6457 10 7 81 2 0 1 1 92 51392 8120 1661144 0 0 4892 5055 5496 3 5 85 8 0 0 0 92 54728 8240 1658044 0 0 558 3128 4712 4 7 82 8 0 1 0 92 53116 8248 1659660 0 0 164 4264 2 4 93 0 0 0 0 92 54196 8268 1658240 0 0 0 40 4265 5 13 81 0 0 1 0 92 53080 8276 1659896 0 0 0 2110 4438 2 2 95 2 0 0 0 92 54

Reprint: Network Port Literacy III: Ethernet Chip Mac and PHY relationships

to the physical layer, when the data is received, the MAC protocol first to determine the input information and whether there is a transmission error, if there is no error, The control information is sent to the LLC layer. The layer protocol is an Ethernet Mac defined by the IEEE-802.3 Ethernet standard. The latest Mac supports both 10Mbps and 100Mbps speeds of two.The Ethernet Data Link layer actually contains the MAC (media access control) Sublayer and the LLC (Logical link Control) sublayer.

How to make the NIC work stably

long light, and in the process of transmitting the signal, the network card signal lamp will keep flashing. If we're on a network connection, found that the network sometimes do not pass the phenomenon, we should look at this time the network card signal is in what state, once found that the network card signal is also flickering, the phenomenon of transmission instability is mostly due to the NIC and computer motherboard in the PCI slot contact caus

Network Port Literacy III: The relationship between Mac and PHY for Ethernet chips

control information in the specified format to the physical layer, when the data is received, the MAC protocol first to determine the input information and whether there is a transmission error, if there is no error, The control information is sent to the LLC layer. The layer protocol is an Ethernet Mac defined by the IEEE-802.3 Ethernet standard. The latest Mac supports both 10Mbps and 100Mbps speeds of two.The Ethernet Data Link layer actually contains the MAC (media access control) Sublayer

Implementation of ACPIPCIHot-Plug in Linux2

Article Title: Implementation of ACPIPCIHot-Plug in Linux2. Linux is a technology channel of the IT lab in China. Includes basic categories such as desktop applications, Linux system management, kernel research, embedded systems, and open source.    1. Introduction to ACPI hot plugging The Advanced Configuration Power Interface (ACPI), developed jointly by INTEL, MICROSOFT, and toshba, enables software, hardware, and operating systems (OS ), the motherboard and peripheral devices manage power u

Implement router and packet filtering firewall in Linux

markets. The installation of PCI cards is relatively simple, as long as the kernel supports, the system correctly identifies the number of cards at startup. The installation of the ISA card is not complex. For details, refer to my previous article.Www.nyfzns.net www.520cat.comThe following figure shows the network interfaces that I have actually used:★Intel etherexpress pro pci100m★RealTek 8029/8139 PCI 10

Explanation and analysis of NIC Driver instances

This article only discusses the general Writing of network device drivers. The Code related to the hardware is omitted because of the different hardware specifications. Are there any mistakes or supplements? You are welcome to raise them. 1. Loading and uninstalling the driver moduleIf the network device (including wireless) is PCI compliant, first register the PCI device (pci_register_driver) with the kern

Summary of the Windows Network Architecture (from the perspective of snow, Author: jbwang)

packets from The miniport driver, and then use the ndis api of miniport characteristics to send data packets to the proto. The biggest advantage of NIDs intermediate driver is that all the data packets of miniport driver must be handed over to protocol driver. Therefore, the network firewall is regarded as a perfect place. Nowadays, many network firewalls use the NDIS intermediate driver to filter and intercept data packets. The filtering rules are set to the mpsendpackets, ptreceive, and ptrec

Beginner's Guide: how to install NICs in Linux

uses and who is compatible with before looking for a Linux driver, such as 3c509, ne2000, and etherexpress. such models are usually printed on the largest fast chip on the network card. Just copy them. The most common use may be the best network adapter, or the ne2000 compatibility card. I use it as an example. Note that many cheap cards are actually ne2000 compatible. For the ne2000 card, the first thing to do is to set the NIC to jumpless mode. many NICs use the PNP mode by default, which

How to find available network adapters on Ubuntu

How to find available network adapters on Ubuntu Do you want to know what Nic you are using in Linux? In Linux, it is easy to find the network card manufacturer. Open a terminal and enter the following command: Sudo lshw-C network If the above command cannot be used in sudo, do not use sudo's privileged mode. Its output looks strange but useful. *-Network Description: Wirelessinterface Product: BCM4360 802.11 acWirelessNetworkAdapter Vendor: BroadcomCorporation Physical id: 0 Bus info

How can I determine whether the server is a virtual machine or a physical real machine ?, Virtual Machine

InstalledLocator: RAM slot #13Size: No Module InstalledLocator: RAM slot #14 ------- Uneven Memory Distribution --- Directly view the product name Dmidecode | grep "Product" [Root @ lixora ~] # Dmidecode | grep "Product" Product Name: VMware Virtual Platform Product Name: paibx Desktop Reference Platform [Root @ oracle sysbench-0.4.12] # dmidecode | grep "Product" Product Name: System Product Name Product Name: P8Z68-V LX ------ Observe the hardware device. If you see that the character

Linux acpi off learning

The content of ACPI is complex. Learning ACPI can at least help us understand the configuration information. This information is obtained from the configuration of the legacy PNP device, to the multi-processor, to NUMA. For example, the current Multiple Core information can only be obtained from ACPI. Many codes for Linux Startup Process the configuration information, such as Linux acpi off and IOAPIC settings. ACPI related devices. Laptop-related devices, including power buttons, batteries, ext

Explanation and analysis of NIC Driver instances (Classic !!!)

1. Loading and uninstalling the driver moduleIf the network device (including wireless) is PCI compliant, first register the PCI device (pci_register_driver) with the kernel ), then, the probe function pointer in the pci_driver data structure points to the detection function to initialize the PCI device and register and initialize the network device at the same t

Linux driver Manual binding and Unbind method

Starting with 2.6.13-RC3, the Linux kernel provides the ability to dynamically bind and Unbind devices and device drivers in user space. Prior to this, the insmod can only be bound and reconciled through the modprobe and rmmod, and this binding and bundling is for the driver and all devices. The new feature can set the connection between the driver and the individual device.Here, we take the NVMe SSD for PCI bus as an example, first execute LSPCI disp

Linux drivers manually bind and Unbind

Starting with 2.6.13-RC3, the Linux kernel provides the ability to dynamically bind and Unbind devices and device drivers in user space. Prior to this, the insmod can only be bound and reconciled through the modprobe and rmmod, and this binding and bundling is for the driver and all devices. The new feature can set the connection between the driver and the individual device.Here, we take the NVMe SSD for PCI bus as an example, first execute LSPCI disp

CPU Overclocking Considerations

can be achieved to increase the volume of traffic So:250mhz x 8 = 2G, or: 100MHz x = 2G But: Obviously the width of the road is better than the number of bars, the PC is the same, generally will not use the latter formula, lower FSB will greatly affect performance. However, FSB on some AMD CPU is inaccurate, but the theory is the same, outside the forest to note that most of the current CPU frequency is locked, can not be lowered or raised. Some people say: understand, add FSB is finished,

Linux View System hardware information (example)

976771071 282231808 83 LinuxCardViewing NIC hardware information# Lspci | Grep-i ' ETH ' 02:00.0 Ethernet Controller:realtek Semiconductor Co., Ltd. rtl8111/8168b PCI Express Gigabit Ethernet contr Oller (Rev 06)View all network interfaces of the system# ifconfig-aeth0 link encap: Ethernet Hardware address b8:97:5a:17:b3:8f ... lo Link encap: Local loopback .....or aIP link show1:lo: If you want to view the d

Inserting an external NIC Port sequence Chaos--linux System

This article is the author of the work of learning in understanding or sentiment, welcome everyone to ask questions, discuss together!!I. Questions raisedThe general motherboard has two NIC interface, Linux system is generally named after boot eth0,eth1, of course, if we do not eth0 and eth1 post-processing, each boot eth0 and eth1 location will not be fixed. Therefore, when the external network card, the problem of port confusion (port name and port of the

Total Pages: 15 1 .... 11 12 13 14 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response