Microsoft SQL Server 2000 best practices for index fragmentation (Part 2)

environment The test in this article uses the following hardware and software environment: Microsoft softwareMicrosoft Windows 2000 Data Center (Service Pack 3)Microsoft SQL Server 2000 Enterprise Edition (Service Pack 2) Hardware PlatformSmall-scale environment:Dell poweredge 1, 64504 Intel Pentium III Xeon 550 MHz processors4 GB RAM Large-scale environment:Dell poweredge 1, 84508 Intel Pentium III Xeon 5

Dmidecode command details (obtain hardware information)

number:" 'dmidecode | grep-A5 "Memory Device" | grep Size | grep-v No | wc-l' Output result: [Root @ sc00006 test] # bash test. shIP:10.0.17.610.0.250.6Product Name:Product Name: PowerEdge R720SKU Number: SKU = NotProvided; ModelName = PowerEdge R720Product Name: 0DCWD1CPU Info:Intel (R) Xeon (R) CPU E5-2620 v2 @ 2.10 GHzIntel (R) Xeon (R) CPU E5-2620 v2 @ 2.10 GHzDisk Info:Disk/dev/sda: 1074 GBDisk/dev/sd

DELL R710 Server does RAID5 disk array graphics tutorial

array card itself, the BIOS of the array card. (typically used to reinstall a system or without an operating system, create a container (Adaptec array card)/logical drive (Ami/lsi array card).Use the Configuration tool software provided by the third party to achieve the management of the card. such as Dell Array Manager. (These software is used for the operating system already installed on the server)Third, the correct identification of your array card model (in this case, Dell for example, in

Dell server hardware information monitoring, automatic generation of server asset information

In the server hardware monitoring, the current industry is mainly based on the following two kinds: 1, the server comes with tools, such as HP's Hpacucli,dell OMSA, etc. 2. Intelligent Platform Management interface (IPMI, full name intelligent Platform Management Interface) Based on the above two kinds, through the Nagios, Zabbix or self-research operation and maintenance platform, such as the package, to carry out early warning operations. As the servers used by the company are all Dell

Dell signs contract with Novell to install SuSE Linux on the server

Dell announced at the LinuxWorld Conference in Frankfurt that it will Install Novell's SuSE Linux operating system on its Dell poweredge server as part of its global agreement with Novell. At a press conference on the Agreement, Judy chavis, Dell's Global Alliance marketing director, said Novell's SuSE Linux Enterprise Server 9 would be used on servers like poweredge 1850, 2800, and 2850, the annual subs

Architecture for Youku, YouTube, Twitter and justintv several video sites

Youku Video Site ArchitectureI. Overview of basic data of the websiteAccording to 2010 statistics, Youku daily average number of independent visitors (UV) reached 89 million, daily average visit (PV) is reached 1.7 billion, Youku with this data to become the Google List of the top domestic video site manufacturers.Hardware, Youku introduced the Dell server mainly in the PowerEdge 1950 and the PowerEdge 860

View the average load of the CentOS Operating System

system performance is good. It is acceptable if the number of active processes per CPU is not greater than 4. If the number of active processes on each CPU is greater than 5, the system performance problem is serious. You can also use the vmstat command to determine if our system is too busy. If it is determined that it is very busy, consider whether to change the server or increase the number of CPUs. Summary: If r is often greater than 3 or 4 and the id is often less than 50, it indicates tha

Linux bug 14258279:scheduling clock overflows in 208 days

) enclos The ure (u) bnx2 (u) Dcdbas (u) serio_raw (u) snd_seq_dummy (u) snd_seq_oss (u) snd_seq_midi_event (u) snd_seq (u) snd_seq_device ( u) snd_pcm_oss (u) snd_mixer_oss (u) snd_pcm (u) snd_timer (u) snd (u) soundcore (u) snd_page_alloc (u) itco_wdt Vendor_support (U) PCSPKR (u) usb_storage (u) shpchp (u) megaraid_sas (u) [Last Unloaded:ip_tables]Dec 22:55:44 TEST-DB01kernel:pid:27243, comm:mysqld not tainted 2.6.32-200.13.1.el5uek #1 PowerEdge R7

Vmware ESX 5.0 Installation and deployment

Recently, our company deployed virtualization, purchased two Dell R710 Server (cpu:64 dual-core, frequency: 2.4GHZ, 32G memory, hard disk: 2 300G do Riad 1, 3 block 2T do Riad 5, 10 block network card), VMware ESX 5.0 was installed on both servers because the virtualization knowledge was only used by some of the client's virtual machine software, groping to today, encountered a lot of problems, looked up a lot of information, took a lot of detours, with the problem to solve the problem of the pr

Dell OMSA Installing the deployment on a Linux server

-cm5. Start the OMSA service with the following command:/opt/dell/srvadmin/sbin/srvadmin-services.sh start6. This completes the installation of OMSA on a Linux server over the Internet.Friendly tip: The Omsa version of Yum Repositor may differ from the version update time published on the website. In this case, Yum installs the version of Omsa v7.3, the official website has been out of the latest patch v7.3.0.1, please note. If you download, install the latest patch, see method two steps.Method

Cisco switching module is introduced into the Dell Blade Server System

Server Recently, Dell said it will be the first time in its second generation Blade server System PowerEdge1855 Cisco's Catalyst Blade server dedicated switch to 3030 of the mutual embedding. The Cisco Works network management software also has a built-in support module for the Dell PowerEdge 1855 Blade Server System. Dell PowerEdge 1855 Blade System Cisco Catalyst Blade Switch 3300 Dell does not provi

The method of locating kernel module crash

Nf_nat_ipv4 nf_nat nf_conntrack ip_tables x_tables ipip tunnel4 ip_tunnel ip6_udp_tunnel udp_tunnel Bonding Joydev input_leds intel_powerclamp coretemp KVM ipmi_ssif ipmi_devintf irqbypass Gpio_ich Crct10dif_pclmul Crc32_pclmul 8 250_fintek Dcdbas shpchp aesni_intel serio_raw aes_x86_64 lrw gf128mul glue_helper lpc_ich ablk_helper I7core_edac cryptd Edac_core ipmi_si ipmi_msghandler acpi_power_meter mac_hid PARPORT_PC ppdev LP Parport autofs4 hid_generic psmouse Usbhid HID PATA_ACPI Megaraid_sa

3 major NoSQL Database performance comparison test report

lineage, natural integration with Hadoop) has long been a powerful proof of its superiority. )   Test environment: Bankmark uses the Yahoo Cloud serving Benchmark (YCSB) test framework as a test tool. All of the tests are performed on physical hardware, without using any level of virtualization. All database tests are performed on a 10-node cluster with 10 servers (Dell PowerEdge R520 (5 units), Dell PowerEdge

View the average load of the CentOS Operating system

the above example, my server is PowerEdge 2850, and the CPU is dual-core and dual-threaded, then 0.09/2 = 0.045 (load value/actual number of CPUs ), the CPU load of this system can be ignored. In fact, the CPU of mainstream servers is very powerful. if it is not a special scenario such as application virtualization, the load is basically very small. According to the previous formula, the CPU load threshold of the Nagios alarm is set to the number of

[Linux knowledge] server performance test-UnixBench

Link: blog. csdn. netjason_asiaarticledetails383090791.1. server performance test UnixBench in DELLR720 and DELLR610 respectively as the test server, because the server configuration is different, the results are for reference only. Download: wgetbyte-unixbench.googlecode.comfilesUnixBench5. Http://blog.csdn.net/jason_asia/article/details/38309079 1.1. server performance testing UnixBench is the server tested on DELL R720 and DELL R610. The results are for reference only because of different ser

Dell IDRAC Server Remote Control settings

example, for your illustrationIDRACStep-by-step setup.The idrac remote Control interface of the Dell server, in the lower right corner of the diagram, has the word "IDRAC"Idrac 's network port on the back of the server is generally marked with the word idrac . In Dell's server, this network port uses a 1Gbps network port, which is faster. In general, theIdrac feature is turned off by default, we need to enable it in the BIOS , first we restart the computer, then enter the BIOS, select IDRAC Se

Resolution of the NIC name em1 issue when installing Centos6.6 on the Dell server

installing RHEL6 into a supported Dell PowerEdge server process, the new network interface name will change to:EmN (EM1, EM2,..)To replace the ethn name used by the motherboard's integrated network port in the past.For PCI Extended Network interfaces, the name will be:Pxpy (PBased on the new naming scheme, EM1 maps ' GB1 ' (em2 mapping ' Gb2 ') to the same label on the server base, making it easier to manage the network interfaces effectively. The na

Installation and deployment of VMware ESX 5.0

Recently, our company has deployed virtualization and purchased two Dell r710 servers (CPU: 64-bit dual-core, clock speed: 2.4 GHz, 32 GB memory, Hard Disk: two 5.0 GB Riad 1, three 2 TB Riad 5, and 10 Nic), and VMWare ESX is installed on the two servers, because the knowledge of Virtualization has only used some virtual machine software used by clients before, I have encountered many problems, checked a lot of information, and made many detours, with the process of solving this problem, I have

Server knowledge details

understanding of the server, which is very easy to understand. The following are the Appearance Features of the server: 1. Large Chassis In terms of appearance structure, the server chassis is generally relatively large. Some servers, although seemingly similar to ordinary PCs, are larger, even for entry-level PC servers, 1 The figure on the left shows the Dell poweredge 400sc entry-level server (currently only $5808 ). For some medium-and high-gr

How do I enable the Dell Computer From UEFI PXE?

How do I enable the Dell Computer From PXE? ? Lander Zhang focuses on On-Demand IT infrastructure O M services for foreign companies, and IT helpdesk hands-on training practitionersHttp://blog.51cto.com/lander Problem description Recently, I am working on it standardization for more than 100 computers of a foreign company customer. The company has determined the model as Dell Elastic Compute service 7370.And the Dell poweredge 5050 SFF. The lapt

Total Pages: 10 1 .... 4 5 6 7 8 .... 10 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.