The first method: System DMESG information inside[[email protected] ~]# grep ' DMI '/var/log/dmesgdmi 2.8 present. DMI:HP ProLiant dl380p Gen8, BIOS P70 12/20/2013The second method:Install the Dmidecode package and use the Dmidecode command to view it;[[email protected] ~]# rpm-qf/usr/sbin/dmidecodedmidecode-2.11-2.el6.x86_64[[email protected] ~]# dmidecode |grep-a4 ' System Information ' System Information manufacturer:hp Product name:proliant dl380p
HP HP DL160 G6 RAID and Server2003 system installation method
HP ProLiant DL160 G6 Server
Manually install the Windows Server 2003 system and manually install all drivers
(Pictures from Xin Pengcheng)
Hardware environment: DL160G6
Software Environment: Windows Server 2003 SP2
Array card: HP Smart Array b110i SATA RAID Controller
Other equipment: U disk
Operation Steps:
1. If you need an integrated array card to do the array, first F10 into th
Bandwidth issues for NVIDIA GPU on HP Xeon 55xx servers
But through the SDK bandwidth test, the numerical value is rather strange.
Host-> device up to 3gb/s, device-> host highest only 3.2gb/s, which is the same as the PCI Express Gen 2.0 5-6gb/s data is relatively large.
Found that other people encountered similar problems on the same HP ProLiant DL370 G6 servers.
http://forums.nvidia.com/index.php?showtopic=104243
The problem with the motherboa
Server
With the advent of the AMD Opteron processor, the 8-way server based on the x86 architecture has greatly reduced the OEM's entry threshold. On the eve of the advent of the dual-core server processor, both the old 8-way server vendors withdrew and more new players were involved. Already the weather of the 8-way server market, the future will bring to users what new ideas?
In the traditional x 8 6 server design, the multi-channel server is the SMP (symmetric multiprocessor) design, its des
Server 2004
If this is the second case, the server to do the gateway, you need a powerful and able to implement the entire LAN protection of professional firewall software, such software is not many, Microsoft ISA Server 2004 is a very good representative product:
ISA Server 2004
function Introduction:
Following ISA Server 2000, Microsoft released the latest ISA Server 2004, which is an award-winning product, whether relative to its predecessor, ISA Server 2000, or relative to other firewal
Once wrote a blog about VMware Virtual disk format: "Thin or thick?" Virtual disk format selection problem, introduced thin and 2 kinds of thick format virtual disk features, also mentioned in the article vi3.x time, Deployment (deploy) or Clone (clone) a virtual machine, can not choose the format, can only be Eagerzeroedthick format, This is a disadvantage of vi3.x, and this shortcoming was overcome in 4.0, now we vSphere4.0 when from the template deployment or cloning a virtual machine, can ch
Memory
Disk
Software
1
Dell Precision WorkStation530 MT1694 MHz
1
Mb
16.9 GB
Microsoft WINDOWS®XP
Application Center Test
Table 2. Web server Configuration
# of Servers
machine/cpu
# of CPUs
Memory
Disk
Software
1
Compaq Proliant-MHz
4
640 MB
GB
Windows Advanced
with the VC module needs to be configured to meet the needs of the scene.The 1:switch port is configured as acess or untagged mode, or the defaultThe VLAN or the specified VLAN can forward untagged frames.2: If the switch port is configured for trunk mode forwarding multiple VLANS,VC will goThe host adapter that has the tag frame to the network, if this is the case,Then you need to configure the VC network as VLAN tunning mode. Connection Host willwill need to be configured to interpret these V
HP DL385 G7 server, you only said M3 or G7. The price you asked is mostly very high. In this case, the salesperson must pay a high price. If you say that the price is too high, they will also say that there are many models and there are many configurations. I will report xx configuration, then you have nothing to say.
Ask the price details to the specific server model, such as IBM System x3630 M3 (7377I09)
Cracking Tactics)The correct way to ask for the price is to report accurate models, such
X86 systems originated from the 8086 chipset, and the main processor of the chipset is made by Intel and AMD. Later, more and more manufacturers applied the chip to desktops, laptops, and servers. In today's enterprise server market, a few vendors account for the vast majority of the market share. Currently, mainstream x86 servers on the market include:
1. IBM x Series servers
2. HP Proliant DL/ML and BL Server
3. NEC Express server
4. Dell PowerEdge
Storevirtual complete decoupling of storage hardware and softwareLefthand introduced VSA (Virtual Storage Appliance) software in 2007 and was renamed Storevirtual Companion HP x86 Universal Server (DL, ProLiant, BladeSystem, etc.) in the second year by HP acquisition Sold together, followed by the introduction of Storeonce VSA. Storevirtual Natural support hardware and software decoupling, which is in line with the characteristics of SDS/SBS storage,
recently got an old server. HP DL380 G6 after installing esxi6.0 , found that the local hard disk will often fall off from time to time, and then have to restart the server, found the relevant information is due to the onboard p410i firmware version is too old to cause, And then prepare to update the firmware. Found several articles about using hpsum to update the firmware in the ESXi host, try this method because it works well for batch servers to update firmwareHpsum 6.01 Remote refresh ESXi s
configured array status.5. Press ENTER to view the status of each drive.DL388G9:This article focuses on the HP ProLiant ML350 Gen8 server Smart Storage Administrator Configuration array method.2. Select HP Smart Storage Administrator (SSA) such as:3. Enter the SSA after the first interface such as:4. Enter the array configuration interface as a sequential selection:5. Select "Create Array":6. Select the required hard drive to configure the array:7. I
The company has two HP servers, namely HP bl460c G7 SmartArray p410i, HP DL360 G5 SmartArray. For various reasons, the operating system CENTOS7 needs to be reinstalled. However, after a variety of efforts, the CENTOS7 installation program is unable to identify the server hard disk.Workaround:1, enter the installation CD, with the upper and lower keys to select the installation of Centos--install Centos7 (note Do not press the ENTER key),2, press the TAB key to install additional configuration, a
achieve full control regardless of the state of the server's operating system.
System Fan function
4 Active Cool 200 Fans
Shape
8 Full-height blades/16 semi-high blades
Supports hybrid configurations
Support BladeSystem
HP ProLiant, Integrity, and storage blade hybrid or homogeneous configuration
Management functions
Insight Control (IC) software license
Availability of power
6
Production Environment host server deployment Summary
Deploy all the host servers of a new project with colleagues over the past two days, and record the general process.Environment:Host model: HP ProLiant DL380 Gen9Basic configuration: 2.40 GB memory, 2 E5-2630 7200 GHz CPU, 12 4 tb sata rpm hard driveRAID card: Smart HBA H240ar (supports RAID1, RAID5, RAID50, RAID1 + 0, etc)In the production environment, host servers are deployed. Generally, the fol
of Linux skills. Some unauthenticated applications may not be suitable for running on Ubuntu and other professional applications such as high availability or cluster, but for the general workload, ubuntu has saved a lot of resources ..
Carr says the other obstacle that Canonical is working to overcome is the lack of hardware authentication for server operating systems. HP will authenticate ubuntu9.04, which will be released for the ProLiant server in
Configuring Servers from scratch
(i) Hardware preparation
One hp ProLiant DL160 G5 Server (hard drive extends to 480G)
A personal computer (Windows operating system)
One Lenovo 4G Flash memory (FAT32 format)
(b) The production of Guide U disk
There are many online production of Linux guide U disk articles, but really can use a few, during the trial of several methods, have failed. The most feasible and simplest method is described directly below.
Unit recently bought a new HP ProLiant DL385 server, while purchasing an HP Smart array G2 disk control array card, configured with 10 146GB of capacity of 10,000-turn SCSI hard drive, now I intend to make these 10 SCSI hard disk raid 5, so that the disk array system to maintain a large number of multimedia information task. To do this, the author quickly opened the server chassis shell and then carefully inserted the HP Smart array G2 disk array card
Information
if (board)
PRINTK (kern_warning "Hardware name:%s\n", board)//through our log information we can find that our hardware name is ProLiant DL360 G7
if (args)
VPRINTK (ARGS->FMT, Args->args);
Print_modules ()//Print System module information
Dump_stack ();//dump information output (call trace starts)
Print_oops_end_marker ()//print Oops End
Add_taint (taint);
}
Analysis of the implementation of this function is not difficult to find a lot
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.