Modem building Chain Process details

Terminal MODEM Step 1| dtr-->| Step 2| txd-->| Step 3| Step 4| Step 5| Step 6| 1, from the terminal to send the DTR signal to the MODEM,DTR signal by the RS232 DTR Foot sent out, tell the modem terminal is ready; 2, the terminal sent TXD signal to the modem, the terminal by RS232 Txd sent a signal to the modem has been kept in logic 1, it is not data, but a handshake signal, this signal tells the mo

DB9 pin Type: RS485 output signal and terminal pin assignment

Tags:. NET white log ack BSP Ace RS232 pin Postwhat you see. DB9 pin-type RS485 output signal and terminal pin assignment . This DB9 needle type differs from the standard RS232 or RS485 DB9 definition, and the DB9 pin type description is only for USB to 485DB9 interfaces.Watermark/2/text/ahr0cdovl2jsb2cuy3nkbi5uzxqv/font/5a6l5l2t/fontsize/400/fill/i0jbqkfcma==/dissolve/70/gravity /center ">The pin correspon

What is the relationship between Modbus and RS485?

RS485is a physical interface, simply said to be hardware. MODBUSis an international standard communication protocol for exchanging data between different vendors (typically industrial use); so-called agreements can also be understood as the "language" mentioned above, it is simply software. RS485 belongs to the wired transmission, so it is necessary to hardware transmission media, the actual is two lines on it, in this two is the actual transmission line is the same signal, just send the signal

How about Ariton ht-842r?

Ariton HT-842R is a low-cost four-port IP voice gateway that can work with most operators ' H.323 or SIP,IP telephony systems and does not need to be upgraded when switching between SIP and H.323 protocols. Provides 4 standard 24V FXS telephone interface, can cooperate with each kind of standard telephone, cordless telephone to use. The Voice gateway does not need to connect the computer to be able to work, 4 standard 24V FXS RJ11 telephone in

Low cost fiber to household (FTTH) solutions

ONACCESSH1004 Optical Network unit of each information point, while providing users with a duplex 100M speed Internet access, CATV broadcast signal and telephone access The ONACCESSH1004 Optical Network Unit provides a single mode single fiber interface, a CATV 75ω coaxial cable RF interface and 4 10m/100m RJ45 interface, a RJ11 ordinary telephone interface, connected with the OnAccess2224 video multiplexing fiber switch CATV signal Transmission adop

Design and construction of structured integrated wiring system

connect, and between terminal equipment and I/O bridge, information sockets are wall, floor, table, soft base type of a variety of standards have RJ45/RJ11 single, double, Various types of porous.---http://bianceng.cn (learn computer)    2. Horizontal wiring Subsystem (horizontal subsystem)    The horizontal wiring subsystem connects the cable from the floor distribution frame to the information outlet on each user's work area, usually on the sam

Raspberry Pi +python+pyserial 2.7 for serial communication

The hand has a CCD Camera (Barcode reader/scanner Module), it is through RS232 communication, with the RS232 to the USB adapter to connect the Raspberry Pi, you can complete the hardware connection. For serial communication, it can be realized by pyserial.First, install Pyserial:Download the latest version of the installation package from Https://pypi.python.org/pypi/pyserial and complete the installation w

Chapter--linux Foundation

through the common port memory, some through the SD card, but also through the RS232 interface. Regardless of which interface is mounted on the hardware, the loading process must provide the following information, including:1: Where to read the user program2: What is the length of the user program?3: After loading complete user program, should jump to where, that is, the user program's execution entrance whereThe second step is to execute the kernel

View serial port information under Linux

RS232 serial Communication Interface: When the communication distance is close (Definition of 9 foot pin:CDC data carrier detection, RXD receive data, TXD send data, DTR data interrupt preparation, GND signal ground, DSR data device ready, RTS request sent, CTS clear send, Dell ringing indication.View serial port information under LinuxCheck whether the serial port is available, can send data to the serial port, such as the COM1 port, Echo HelloWorld

Chapter--linux Foundation

loading methods, such as some through the ordinary parallel port memory, and some through the SD card, there are also some through the RS232 interface. Regardless of which interface is loaded on the hardware, the loading process must provide the following information, including:1: Where to read the user program2: What is the length of the user program?3: After loading the user program, should jump to where, that is, the user program run the entrance

PowerHA profile "Turn"

access support. PowerHA Terminology PowerHA uses many terms. They can be divided into two categories: topological components and resource components. The topology component is basically a physical component. They include: node : System P server can be a separate partition or VIOS client network : IP Network and non-IP network communication interface : Token Ring or Ethernet adapter communication Device : RS232 or The heartbeat mechanism of the disk

Serial Communication Foundation and S3C2410 UART Controller

interface, D-socket with a 25-pin or 9-pin connector, as shown in Figure 5-5. Figure 5-5 The serial communication between microcomputers is implemented according to the interface circuit designed by RS-232C standard. If a telephone line is used for communication, the connection between the computer and the modem is based on the RS-232C standard. The principle of connection and communication is shown in Figure 5-6. Figure 5-6

Single-chip microcomputer and (serial screen) touch screen communication based on Modbus Protocol (graphic)

protocol, as long as the single-chip microcomputer in accordance with the Modbus protocol to send and receive data, you can communicate. The touch screen and MCU are connected directly with RS-232 or RS-485 standard interface, and the transfer rate is set to 9600bps. Figure 1 is the circuit diagram of the system. Figure 1 System circuit diagram Set AT89S51 microcontroller Txd, rxd port to asynchronous serial communication mode, after the MAX485 chip to convert TTL level to RS485 level, and

Python's PYQT multithreaded serial Code Analysis

"," recorded in the following format: \ n RH Space t\n example: \ n RH (0~100): 66.6\n T (0~200): 9.8\n input: 66.6 9.8 ", Qlineedit.normal," 66.6 9.8 ") if OK = = True:data = Re.findall (' ^[0-9]+\.[ 0-9]+\s+[0-9]+\. [0-9]+$ ', Data.rstrip ()) If Len (data) = = 0:self.showmsgbox (' Wrong format, re-entry ') Else:data = Data[0].split () print (data) self.datadict[' Rhldy '] = data[0] self.datadict[' tldy '] = data[1] IF Self.getmcudata () is None:return None print (self.datadic

Cost-effectiveness of integrated access network device transmission

, reduce the number of devices, and improve the cost-effectiveness and market competitiveness of devices. An integrated array of service interfaces for access networks to meet the needs of different users Except for the common STM-1/4 group interface and 2 MB/34 MB/45 MB/140 MB/STM-1 branch interface, the blu-ray module can also provide RS232, V.24, V.35, 2/4 audio, and 10/100 MB Ethernet interfaces to meet the needs of different users. For example, y

The influence of Delphi serial communication data bit length on data transfer

For serial communication, the effect of setting data bit length on communication isIn the serial data communication, you will see the serial port parameter settings. Where the "Data bits" setting, there are four options, namely 8, 7, 6, 5. So how does changing this parameter affect the transfer of data?I'm going to do an experiment, through the oscilloscope to observe the communication process, can analyze the results as follows:For example, the data bit is set to 5. Then it is equivalent to spe

Video Transmission Using five types of cables in Dynamic Information Publishing

display screen. However, if you cannot transmit the video content to the display screen, everything is blank! In the real world, buildings were built at least in the 1980s S, and are generally not designed for the cabling requirements of the Information Age. Cabling slots and channels are generally crowded. Cables required to support high-definition videos (VGA or XGA at least) (for example, coaxial cables connected at the top of a 5 BNC connector or standard VGA cables connected at the top of

Knowledge of nine Cisco Routers

versions.However, note the following:Only the Fast Ethernet hybrid network module can support these two wan interface cards.The network modules supporting these two interface cards are as follows:NM-1FE2W, NM-2FE2W, NM-1FE1R2W, NM-2W.The Ethernet hybrid network module does not support the following features:NM-1E2W, NM-2E2W, NM1E1R2W. 4. What is the maximum rate of synchronization supported by Cisco3600 series routers (4A/S, NM (8A/S network module and WIC (2A/s wan Interface Card? These Cisco

232 The RealCom protocol in the Network Interface

RealCom name. Users who use the 232-to-net port for the first time are unfamiliar with this Protocol, here is an introduction. 232 is the abbreviation of RS232, which is a type of serial port. Here, the COM of realcom also refers to the serial port. We can see on the computer that COM1 and COM2 correspond to this 9-pin serial port, because the communication between early computers was dominated by serial ports, so the serial port represents communica

Application point of view: a comprehensive explanation of troubleshooting methods for programmable Switches

-controlled switch failure phenomenon: the audible and visual alarm signals in the total alarm box and the current system clock display are none. The maintenance station enters the "service operation" menu to observe, and the "module power supply operation diagram" is blank. The switch device runs normally. Analysis and maintenance: the maintenance station can perform online operations, and the switch runs normally. This phenomenon should be caused by the failure to collect data such as the curr

Total Pages: 15 1 .... 6 7 8 9 10 .... 15 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.