PCB optimization Design (ii) reprint

test points, the relevant design requirements are as follows:(1) test points evenly distributed across the entire PCB, it is generally required that each network must have at least one Test probe to contact the testing point.(2) Priority of the test point selection: preferably a round pad, followed by the device pinout, the last hole is the most test point. SMD devices preferably using a circular pad to do test points, OSP processing process PCB shou

2.ok6410 Hardware Introduction

strict accordance with the CE,CCC and other domestic and foreign electronicproduct certification standards, fully consider the integrity of high-speed signal and other electromagnetic compatibility measures to ensure OK6410 Development Board inReliable operation in harsh electromagnetic environments.OK6410 the software system currently supports WinCE 6.0 , LINUX2.6.28 , Android2.1 as wellUc/os-ii , a standard board-level support package ( BSP ) and open source, which contains all the drivers of

Tell me about timing (reprint)

design. Gated clocks are typically generated by a counter divider. Use the clock resources provided by the FPGA as much as possible, using DCM as Deskew.Offset constraint not satisfiedThe first thing to do is to ensure that offset is written correctly.Then ensure that the input/output data into the FPGA in the register with a beat, the middle do not add the combination of logic. Register pack to IOB to ensure that the offset constraint is met to the maximum extent possible. (Similarly, as menti

STM32 Series Arm Single-chip microcomputer introduction

, which takes less than 6 microseconds to wake the microcontroller from Stop mode. Memory and package options:   prior to the stm32f105 and STM32F107 Interconnect series microcontrollers, STMicroelectronics has launched the STM32 Basic series, enhanced series, USB basic series and enhanced series, and the new series is based on the 72MHz processing frequency of the enhanced series. Memory includes 64KB to 256KB Flash and 20KB to 64KB embedded SRAM. The new series is available in three packages o

Spartan-3e starter kit board getting started

syntax in the process management area to check whether there is a syntax error. 9. Double-click synthesize-XST to complete integration. 10. Select simulation in view, right-click the project management area, select new source, select maid, and enter file name 11, 12, 13. Enter the test code. In this example, it is in the red line area of the customer zone. Other examples are not required! 14. Right-click the simulate behavioral model and select Properties to set simulation parameters. 15

Win32 serial programming (to: Han yaoxu)

In industrial control, Industrial Computer (generally based on Windows) often needs to communicate with smart meters through serial ports. Serial Communication is convenient and widely used.Generally, the Industrial Computer communicates with each smart meter through RS485 bus. The RS485 communication mode is half-duplex and can only be round-robin by the industrial control PC as the master node on each Int

Concept of gprs dtu and working principle of DTU

Source: http://blog.csdn.net/bichenggui/article/details/7889638 Recently, a data center solution based on grps dtu data transmission needs to be developed, so I found some materials. I personally think it is very useful. Gprs dtu is the full name of the GPRS data transmission unit. Currently, there is a more explicit Convention on gprs dtu in China: gprs dtu is specially usedSerial Port DataPassGPRSNetworkThe GPRS wireless device for transmission. Four core functions of gprs dtu: 1) internal int

Detailed description of Serial Communication Programming

In industrial control, Industrial Computer (generally based on Windows) often needs to communicate with smart meters through serial ports. Serial Communication is convenient and widely used.Generally, the Industrial Computer communicates with each smart meter through RS485 bus. The RS485 communication mode is half-duplex and can only be round-robin by the industrial control PC as the master node on each Int

Application of Embedded linux in Industrial Control

processing control procedures. Therefore, communication between a single-chip microcomputer and a single-chip microcomputer or a host computer is usually established through RS232 or RS485. These networks have problems such as slow communication speed, poor networking functions, and difficult development. Industrial Ethernet has been gradually improved and more applications are available in the industrial control field. Industrial Ethernet uses TCP/I

Embedded software and hardware debugging problems

1. Serial numbers cannot be sent and received continuously during RS485 usage. At first, the problem was that the TX of maxcompute needs to be connected to the pulling resistance, and 20 K of the large resistance cannot be used. Using a strong pulling resistance of less than 10 can solve the problem. Later I found the problem. When the number of 0 s exceeds 10, I found that the problem was caused by the high common mode voltage. I handled the two 48

Siemens PLC Serial communication mode

Three ways of Siemens PLC serial communication time: 2015-10-25-14:31:55 Edit: Electrician section: Siemens PLC Introduction: Siemens PLC serial communication Three ways, divided into RS485 serial communication, PPI Communication, MPI communication, free port mode Siemens PLC and the computer serial communication, S7-200 Series PLC communication port 3 kinds of working methods.Three ways of Siemens PLC serial communication1,

Anonymous fingerprint access no admin account how to add employees

) this.width=650; "src=" http://s3.51cto.com/wyfs02/M01/73/12/wKiom1Xzy2zDun-HAAJ4GrYTKhk376.jpg "style=" float: none; "title=" Image 2.png "alt=" Wkiom1xzy2zdun-haaj4grytkhk376.jpg "/>Then find the manufacturers and models, call the manufacturer phone advice how to increase the administrator.How to connect to the machine, how to wireConnected to the machine in the following two ways1. network Settings IP address (machine IP is not the default, no administrator can not see IP information) 2.

I. Superio communication mechanism

1.1 Application ScenariosThe interaction object of communication platform includes two aspects: first, interacting with hardware products. Second, interacting with software products. Basically these two aspects, communication platform will generally be used in two scenarios:1) Communication platform application on PCMainly used in the automatic station of the industrial computer, through rs485/rs232, RJ45, 4-20ma and other ways to collect data informa

TTL level, CMOS level, 232/485 level, OC Gate, OD gate Basics

1.rs232 levelOr the serial level, some even say the computer level, all these statements, refers to the computer 9-pin serial port (RS232) level, using negative logic,-15v ~ -3V Rep 1+3V ~ +15v Rep 02.rs485 and RS422 levelSince both use differential transmission (balanced transmission), so they are level mode, generally have two pin, a, bVoltage difference between the sending side AB+2 ~ +6v:1-2 ~ -6v:0Voltage difference between the receive-side ABGre

Summary of problems in the process of tq2440 and Siemens S7-200 PLC free port communication

1. After installing the PLC programming software Step 7 microwin on Windows 7, can the communication between the programming software and the PLC fail? Cause: Step 7 microwin does not support win7 very well Solution: Install the Virtual Machine in win7, the XP system in the virtual machine, and step 7 microwin under XP 2. One-way data transmission: the PLC sends correct data to PC serial 1 (baud rate 9600), but two-way data transmission: PC serial 1 sends data to PLC first. After the

VC + + Serial Communication programming detailed

VC + + Serial Communication programming detailedReprint Address: http://www.jizhuomi.com/software/309.htmlIn industrial control, industrial computer (usually based on Windows platform) often need to communicate with the intelligent instrument through the serial port. Serial communication is convenient and easy to use and widely used.In general, the industrial computer and the intelligent instrument through the RS485 bus communication.

I. SuperIO communication mechanism. SuperIO Communication Mechanism

I. SuperIO communication mechanism. SuperIO Communication Mechanism1.1 application scenarios Communication Platform interaction objects include two aspects: first, interaction with hardware products. 2. Interaction with software products. Generally, communication platforms are used in two scenarios: 1) The communication platform is applied to PCs. It is mainly used in automatic station industrial computer to collect data of hardware devices through RS485

A conversation with a first-line Linux embedded development project Master

pieces of Flash group), but these two aspects, basically have a good driver, such as network card driver has very many. Block device drivers, the hardware layer already has a common interface. Whether nor flash or NAND flash, the file system layer has many, very mature file systems, such as JFFS2, Yaffs, YAFFS2, EXT2, EXT3, ROMFS, Cramfs and so on. No need to study again, learn to apply it.Other devices, such as AD, DA, CAN, RS485, and so on. Need to

Java Web under the serial communication

Recently in the Java serial communication, mainly with the PC through the serial port from the RS485 read data, and through the CRC cyclic redundancy check, to receive the correct data parsing, insert database MySQL, and SSH technology to the database data in tabular form and chart displayIdeas:1. In order to read data from the RS485, because there is no hardware device, the system is Win7, so the virtual S

Network Fundamentals + Database Basics Notes

Label:1.rs-485 is divided into two main categories: two-line, four-line. Wherein, the former requires two data lines, can be used for half-duplex communication, the latter requires four data lines, can be used for full-duplex communication. Therefore, RS-485 has a minimum of two data information numbers. The RS485 uses the differential signal negative logic, -2v~-6v represents "0", and +2v~+6v represents "1". RS48

Total Pages: 11 1 .... 4 5 6 7 8 .... 11 Go to: Go

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.