Zheng Yi 20100810 is affiliated with section 07. Miscellaneous

Lao Zhao wrote an article about the problems that occur when Windows frequently opens and closes ports. he tested the MongoDB Database Service in cent OS using TCP connections from Windows Web Server 2008 R2 and ran out of socket connection resources.ProgramReport "operations on sockets cannot be performed because the system buffer space is insufficient or the queue is full ." Error.

Socket connection resources are exhausted, which is common in Windows server. If the user program is well written, it is generally caused by some default parameters set by Microsoft (or other software vendors.

I have previously written an article titled 02-twisted about the long link of Web server socket. | 07. miscellaneous | Python describes another common problem of Windows Server: In the python development language, compile a web server using the twisted framework to receive Google Reader pushed by the hub server of Google pubsubhubbub.ArticleWhen sharing information, the file descriptor reaches the upper limit. This mode is characterized by using twisted. Web. server to connect to the pubsubhubbub hub server. Both parties support reuse of connections. It is reasonable to say that since long connections are maintained and socket connections are reused, this"Too plugin file descriptors in select"Error. Here, the knowledge point is that in windows, the select module file descriptor is a maximum of 512, and in Linux, the limit is 32767. If the limit is exceeded, an exception similar to the above occurs.

 

Lao Zhao's article pointed out an interesting knowledge point: the temporary port number can be assigned a range,

Definition of temporary port number range

When a client program (such as a browser) initializes a connection to connect to a remote service (such as a website), the client opens an "Ephemeral (temporary)" port, generally, the port number is randomly allocated. You can use the Microsoft tool tcpview.

When this process assigns a port number for the outbound connection, the allocable range of the port number is related to the operating system. One of the main influencing factors isMaxuserportIn the Registry's HKEY_LOCAL_MACHINE \ SYSTEM \ CurrentControlSet \ Services \ Tcpip \ Parameters.

The following table lists the port ranges that can be allocated to different Windows operating systems:

Operating System

Maxuserport
Numeric Value
Description

Port range, if maxuserport
Not Defined

Port range, if maxuserport
Defined

Minimum value

Maximum Value

Windows NT/2000/XP/2003

Ending Port

From 1025 to 5000

1025 to [maxuserport]

5000

65535

Windows 2000/XP/2003 with kb951748/kb951746

Ending Port

From 49152 to 65535

1025 to [maxuserport]

5000

65535

For Windows Vista/2008

Number of Ports

From 49152 to 65535

49152 to [49152 + maxuserport −1]

255

16384 bytes †

Table 1 port range

Of course, if you install some Microsoft services on the server, the maxuserport parameter will be automatically modified. For example, Small Business Server 2000/2003 will be changed to 60000, and ISA server will be changed to 65535, the Exchange Server 2003 is changed to 60000.

After reading this table, you will know:

1. Do not use a port number smaller than 1025;

2. Try to use the systemTemporary port range (beyond the ephemeral port range)For example, if you define the port number to be opened by your application as 8000, rather than 5000.

3. Reuse connections.

After checking my laptop (Windows XP) and server (Windows 2003), The maxuserport parameter is not set in the registry. Therefore, the port range is the default value. on the server, the allocable temporary ports are from 1025 to 5000.

 

Back to the problem of opening too many file descriptors,

Failed to reuse port + keep persistent connection effective

If there are enough Google Reader users to listen to and these users share articles in a centralized manner, Google pubsubhubub hub server will push the data at an extremely fast speed, in this case, if the socket port fails to be reused and the persistent connection policy takes effect, the file descriptor opened on the port listened by the twisted web server quickly burst.

Solution:

1. Refer to 02-twisted to build a long socket connection for Web Server | 07. Miscellaneous | python,

Twisted. web. server. the initialization function of the site class has an optional parameter timeout. Its default value is 60*60*12, that is, 12 hours. It aims to automatically close idle ports when timeout occurs. In our scenario, the timeout time is too long, so many socket connections in the established State will accumulate.

Therefore, we can reduce it to 15 minutes (or shorter) to automatically disable connections that are not reused as soon as possible. Run the following command at the beginning:
Reactor. listentcp (8080, site (mywebresource. Setup (), Timeout = 60*15))
You can.

2. Refer to 03-pubsubhubbub and twisted persistent connections capabilities | 07. miscellaneous | python, after receiving the data pushed by the other server, it is asynchronously thrown to another method for parsing and processing. The render_post method immediately returns the not_done_yet flag, and the asynchronous data processing is successful, and then finish the current request.

 

Reference resources:

1. Problems with Windows ports frequently opened and closed;

2. Choosing a TCP port for a network service;

3. 02-twisted: long socket connection problem for Web Server construction | 07. Miscellaneous | Python;

4. Persistent connections capabilities of 03-pubsubhubbub and twisted | 07. Miscellaneous | Python

5. TCP-Wait Status and its impact on busy servers.

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.