24-port full-Gigabit Switch error frame Filtering test QoS Test

Source: Internet
Author: User


24-port full-Gigabit Switch error frame Filtering test QoS test master knowledge of the following 24-port full-Gigabit Switch knowledge, such as broadcast forwarding and latency test. You can easily select your preferred method to implement 24 full gigabit switches. Many methods will make you suddenly enlightened. Test of broadcast forwarding and latency of www.2cto.com this test measures the packet loss rate of the tested device when forwarding the broadcast data frame and the delay of the broadcast data packet passing through the 24-port full Gigabit Switch. The 24-port full-gigabit switch of the error frame Filtering test should be able to filter out some wrong data frames. In this test, the tester simulated three types of error frames to test the capability of 24-port full Gigabit Switch to filter error frames. These three types of error frames include too small frames (frames smaller than 64 bytes) large Frame (data frame larger than 1523 bytes) and CRC error frame. Alcatel, D-Link, and Asus 24-port full-gigabit switches do not filter out ultra-large frames. According to engineers, the 24-port full-gigabit switch supports Jumbo frames, the 24-port full-Gigabit Switch treats it as a normal frame, so it is not filtered out. In daily 802.1p usage, QoS testing may include the following different usage methods. One category is that different ports are connected to several different servers in a VLAN, the application priority of each server may be different. For example, the server that requires financial query service has a high priority. The ports connected to the server should have a high priority. The other category is the connection between 24 full Gigabit Switches and switches, and the 24 full gigabit switches should distinguish the Data priorities of different VLANs. Based on the above different practical applications, we simulate the following test environment.
The first type is the four tested ports in the same VLAN. This type of test simulates different servers or PCs to connect to a local 24-port full-gigabit switch, the basic principle of the test is that three ports send data packets to one port, resulting in port congestion. view the results of 24 full Gigabit Switches processing data packets of different priorities. In this type of test, I have two types: one is that the test instrument sends packets with VLAN tags, and the packet priority is set to 7, 4, 3. One is that the test instrument sends packets without VLAN tags. Each 24-port full-gigabit switch enables the port priority. Then, we will observe the results of the 24-port full-gigabit switch processing different priority packets.
The second type is that the tested port is divided into three different VLANs. This type of test simulates the Trunk connection between the 24-port full-gigabit switch and the switch, many packets with different VLAN tags are floating on this connection. Therefore, the congested port belongs to different VLANs at the same time. We tested whether the Trunk link connected to a full Gigabit Switch with 24 ports can distinguish data with different priorities when packets with different VLAN tags pass through the same data link. The purpose of the test is to ensure that data packets with a higher priority are not lost, and that data packets with a lower priority are treated differently from those with a lower priority.
The test method is to send data frames from three ports to 4th ports at the same time. Each port starts from 30% of the load, and then increases by 10% each time until 100% of each port, causing congestion, view the results of processing data frames of different priorities on the 24-port full Gigabit Switch. In the final test results, most of the 24-port full-Gigabit Switch testing targets, GigaX 2124X high-priority data packets always have packet loss, when the packet sent by the DGS-3024 is tested without a Tag and the three ports are not in the same VLAN, the packet loss is 100% at the first level under the 2% load, and the test is normal in other cases.
Only one test image is provided for readers to view other websites ). QoS test results (Green indicates the high-priority data frame loss rate, blue indicates the low-priority data frame loss rate, and the high-priority data frame loss rate must always be 0 during the test, total indicates the Total frame drop rate ).
 

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.