3.7.4 Tri0 and Tri1 Nets

Source: Internet
Author: User
Tags nets

Frm:ieee Std 1364?-2001, IEEE standard Verilog? Hardware Description Language

The Tri0 and Tri1 nets model nets with resistive pulldown and resistive pullup devices on them. When no driver drives a tri0 net, it value is 0. When no driver drives a tri1 net, it value is 1. The strength of this value is a pull. See Clause 7 for a description of strength modeling.

A tri0 net is equivalent to a wire net with a continuous 0 value of the pull strength driving it. A tri1 net is equivalent to a wire net with a continuous 1 value of the pull strength driving it.

A truth table for Tri0 are shown in table 6. A truth table for TRI1 are shown in table 7.

3.7.4 Tri0 and Tri1 Nets

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.