Ethernet Channel Analysis
Ethernet channel ------ it is intended to review previous learning and not to waste
Note Ethernet conditions:
1. The member ports must be in the same slot module. 2. The member ports must have the same type (1-gigabit electrical ports, 1-gigabit optical ports, and 10-Gigabit electrical ports) and speed 3. The member ports must work in full duplex mode 4. A maximum of 16 trunks can be bound to GE port 5. When the FE Port is bound, the member ports must belong to the same port group; on the BH-2GBIC6GTX48FE module, port 9-32 belongs to the same port group, and port 33-56 belongs to the same port group. Up to five trunks can be bundled with the ports in the same port group. When a user configures Trunk, the user input must comply with the above principles. If the above principles are not met, the user configuration error will be prompted. 6. When binding the GE ports of the BH-24GE-TX and BH-24GE-SFP module, the member ports must belong to the same port group, where ports 1-12 belong to the same port group and ports 13-24 belong to the same port group. 1. Mainly set on swith0 and swith1 switches:
Switch (config) # int range f0/1-3
Switch (config-if-range) # channel-group 1 mode on
Add f0/1, f0/2, f0/3 to the Ethernet Channel group 1 and enable the Ethernet channel. Result: PC0 and PC1 can ping each other.