EMC testing consists of 4 main items:

1. ESD

Using electrostatic gun test, contact voltage ±6kv, the whole box and the internal visible metal parts are detected;

Air discharge positive and negative 8KV, detection of the box and the internal metal parts (such as Board jam body), the special detection of 220V power Plug and switch place.

Note: The contact discharge and air discharge test is different from the electrostatic gun tip, contact discharge tip for sharp metal.

2. Surge

Surge Test Power Interface: L, N, PE. Between the lines 1KV, the line between the ground 2KV, need to test 4 phases.

Actual test voltage: Phase 0 and 90 with positive voltage, phase 180 and 270 with negative voltage.

3. EFT

EFT Test Power Interface: L, N, PE.

The test voltage is positive and negative 2KV, the Power 3 line between any combination (L, N, PE simultaneously applied), 5KHz.

4. Radiation

Test two times: the antenna is placed horizontally once and placed vertically once.

EMC field-tested-eft, ESD, surge, and field radiation

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.