When configuring the HP switch, connect to the Console line of Cisco directly at startup, with the default baud rate. However, the command line does not display anything, so I thought the machine was broken and I changed several, the baud rate has also changed a lot. I also asked a senior network engineer, later, when I tested the brocade switch, a customer asked me whether the Console line of the brocade switch was a direct line or a cross Line. At this time, I remembered that the line was wrong, at last, we got a line from the HP company before we could test the device. Jack, HP has a dedicated line. In the process of tears, I hope I can give a prompt to the students who have seen the article.
During the vswitch test, all the configuration files of the HP switch must be cleared to avoid affecting the test results. Clear the configured command erase startup-config.
1: when the power-on HP switch is powered on, if it works normally, the system startup information will be displayed on the connection command line interface. If the power-on does not respond, check the power supply, fan, and other hardware.
Information about power-on startup of HP 2650:
ROM information:
Build directory:/sw/rom/build/fishrom (f02)
Build date: Sep 12 2002
Build time: 15: 54: 09
Buildversion: H.07.01
Build number: 5823
OS identifier found at @ 0x7c800000
Verifying Image validity...
CRC on OS image header Passed
CRC on complete OS image file Passed
Valid OS image @ 0x7c800000
Decompressing... done.
Initializing ..
2: After the system is started, the default user name is blank and the password is blank. Press enter several times to go in.
If you have a password in privileged mode, you need to recover the password.
If the password is forgotten, press the clear button on the switch panel. After you click the clear button, the password and user name for the switch are deleted. You can use the reset and clear buttons on the panel to restore the factory value of the device. Press and hold the reset and clear buttons at the same time. After about five seconds, open the reset button and hold down the clear button, and other panel sefltest, open the button. To protect the vswitch security, place the vswitch in a safe place.
3: view the switch output one by one:
A: Show version. Check the version and model.
HP # shoversion
Image stamp:/sw/code/build/fish (f02)
Oct 22 2002 09:42:24
H.07.02
86
Boot Image: Primary
HP #
B: Show interface brief: Check whether the output port is the same as the number of physical ports.
HP # sho inter brief
Status and Counters-Port Status
| IntrusionFlow
Port Type | AlertEnabled Status ModeCtrl
---- --------- + -------------------------------------
110/100 TX | NoYesDown100FDxoff
210/100 TX | NoYesDown100FDxoff
310/100 TX | NoYesDown100FDxoff
410/100 TX | NoYesDown100FDxoff
510/100 TX | NoYesDown 100 FDxoff
610/100 TX | NoYesDown100FDxoff
C: Check whether the optical port is running normally if there is a optical port. Check whether the light port indicator is healthy by Ping.
If the hp tc port does not require command conversion, the optical port is automatically started after the optical module is connected. The electrical port is automatically closed and the electrical port needs
The electrical eloquence of the optical module can be used normally. The following uses 2650 as an example.
D: if the device supports POE, you can use a good POE device to test whether the POE power supply is normal.
4: You need to check the License for devices that require License to support functions such as OSPF and VRRP.
If the machine requires License to support these features, you need to purchase License.
HP 5300 series switches support OSPF, 5400 series require licenses, and 2600 does not support OSPF
HP5400 supports VRRP and requires a license. 5300 supports XRRP without a license.
HP5300 supports PIM, 5400 requires a license, and 2600 does not support PIM