Hub leakage causes computer to drop wire

Source: Internet
Author: User

The two 16-port hubs are connected to a local area network, but half of the computers are often dropped off for no reason, and one of the hub LEDs does not blink. Turn off the hub power, reopen it, and the network is back to normal, but after a while the failure occurs again.

This situation may be preceded by an attempt to press the crimping clamp to suppress the connector if the problem persists. Suspicion is the voltage problem, connected with the filtering function of UPS, the fault still exists, hand contact to the hub, found a slight electric shock feeling, the light of the hub does not flicker, it is suspected leakage caused by the fault.

Open the Hub, check the power cord of the hub, one end is a three-phase line, the other end is a two-phase line, there is no connection ground. Re-replace the power cord and the failure can be resolved.

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.