Ibm ds Storage Upgrade Controller Firmware

Source: Internet
Author: User
Tags ibm support

The Microcode to be upgraded includes Controller, ESM, and Drive.

1. Upgrade Controller firmware

Before upgrading, you have to go to the IBM official website to download the latest firmware version, the link address is http://www.ibm.com/servers/storage/support/disk, this link is useful, not only firmware, but also the relevant redbook, some known defect and corresponding workaround.

1.1 download Microcode


The Controller's Microcode includes two packages:
1. controller firmware
2. NVSRAM

The settings of NVSRAM are similar to those of the host system BIOS. firmware and NVSRAM are tightly bound together and are not independent.

650) this. length = 650; "height =" 484 "border =" 0 "width =" 557 "src =" http://img1.51cto.com/attachment/201301/22/731446_1358842380uV0U.png "alt =" image "title =" image "style =" border-top-width: 0px; border-bottom-width: 0px; border-left-width: 0px; "/>

Choose browse> system storage> Disk Systems> Mid-range disk systems"

650) this. length = 650; "height =" 232 "border =" 0 "width =" 244 "src =" http://img1.51cto.com/attachment/201301/22/731446_1358842382dZFR.png "alt =" image "title =" image "style =" border-top-width: 0px; border-bottom-width: 0px; border-left-width: 0px; "/>

650) this. length = 650; "height =" 411 "border =" 0 "width =" 644 "src =" http://img1.51cto.com/attachment/201301/22/731446_1358842384VhDd.png "alt =" image "title =" image "style =" border-top-width: 0px; border-bottom-width: 0px; border-left-width: 0px; "/>

Click to download

650) this. length = 650; "height =" 402 "border =" 0 "width =" 644 "src =" http://img1.51cto.com/attachment/201301/22/731446_1358842387Ub7a.png "alt =" image "title =" image "style =" border-top-width: 0px; border-bottom-width: 0px; border-left-width: 0px; "/>

650) this. length = 650; "height =" 355 "border =" 0 "width =" 644 "src =" http://img1.51cto.com/attachment/201301/22/731446_1358842389twaN.png "alt =" image "title =" image "style =" border-top-width: 0px; border-bottom-width: 0px; border-left-width: 0px; "/>

1.2 preparations before Upgrade:

1. Check whether the firmware you want to upgrade is compatible with the installed multipath!
2. Ensure that the system status is optimal.
3. Read the relevant readme files before upgrading to ensure compatibility
4. Both controllers must be online and accessible.
5. Save All Support Data Collection before the upgrade.

1.3 The following situations cannot be upgraded:
1. Unsupported controller type or different types of controller in the same storage system
2. failed drives
3. There are hotspare disks in use
4. array in incomplete
5. Some operations, such as defragmenting, drive firmware in downloading, or some other operations in progress
6. There are missing Luns in the storage
7. The controller is not in the optimal status.
8. The storage partitioning database is upt
9. invalid appears in the data
10. The Needs Attention status is displayed.
11. storage subsystem does not respond. SM cannot communicate with storage subsystem.
12. event log entries is not cleared

1.4 upgrade order
1. Update the host's SM to ensure that the correct version of the multi-path software, Storage Manager, is installed.
2. Update ESM to the latest version, followed by controller firmware. Expired ESM firmware will make the expansion cabinet inaccessible after the controller firmware is upgraded. The ESM firmware required by each controller firmware is included in the readme file.
3. After updating controller firmware, the next step is NVSRAM. The two parts must be upgraded together or quickly upgraded in order.
4. Any power or network failure during the upgrade may cause configuration interruption. Therefore, the power off DS3500 or management console cannot be used during the upgrade process.

In short, the sequence is ESM firmware -- Drive -- Controller firmware-NVSRAM.

1.5 upgrade process

During the Upgrade process, right-click the place where Storage Manager manages the subsystems and "Upgrade Controller firmware" will appear. This is generally used for major version Upgrade, for example, Upgrade 6 to 7. Another way is to upgrade firmware of Controller/ESM/Drive in "Advanced" -- "Maintenance" -- "Download", which is generally used for minor version upgrade, such as 7. upgrade xx to 7.xx.

After the preceding conditions are met, the system can be upgraded. Upload the previously downloaded Controller and NVSRAM firmware. Upload is Download). By default, transfer firmware and NVSRAM will be activated immediately, but you can also set transfer first, and then activate later, such as the bottom line.

650) this. length = 650; "height =" 484 "border =" 0 "width =" 338 "src =" http://img1.51cto.com/attachment/201301/22/731446_1358842391R41m.png "alt =" image "title =" image "style =" border-top-width: 0px; border-bottom-width: 0px; border-left-width: 0px; "/>

Firmware is transmitted to one of the controllers and then copied to another controller. Both controllers perform CRC verification on firmware image. If the verification is OK, firmware will be marked as ready and can be activated. If any controller Validation result is failed, both controllers will mark the firmware image as invalid and cannot be activated. An error is returned to the console.

During the activation, the first controller transfer all the Luns to another controller, and then reboot and activate the new firmware. Then it takes over the LUN, and it is the second controller upgrade. When both controllers are up, the LUN will be redirected to the preferred path again!

If transfer firmware image is not immediately activate, the normal controller reboot or power cycle will not activate the new firmware. It takes effect only when the user selects activate firmware.

1.6 Some Tips

1. During the upgrade, power down or network failure may cause configuration interruption. Therefore, do not disable the DS5000 storage system or management station during the upgrade process. If you use in-band management, there will be an FC hubs. Make sure that no device connected to SAN is powered up during the upgrade. Otherwise, loop initialization is triggered and the upgrade process is interrupted!

2. If you want to upgrade the Controller firmware from 6.xx. XX. XX to 7.50.13.00 or later, you must first upgrade it to 7.1x.xx.xx or 7.36.xx.xx.

3. To manage DS5000 with the firmware version of V7.6, the SM must be upgraded to V10.60. Therefore, you must upgrade the SM host software before executing the firmware upgrade. SM V10.60 can no longer manage the storage of CFW 5.x.

During the upgrade process, you must connect to two DS5000 controllers. You cannot connect only one controller to perform the microcode upgrade. Therefore, the two controllers must be either accessible through FC or Ethernet, and the two controllers must be in the optimal state.

Ii. Upgrade ESM firmware

Some new Drive codes must be supported by new ESM

In EXP5000, EXP520, EXP810 replace ESM, there is a firmware synchronization feature to ensure that the new ESM firmware is automatically synchronized with the existing firmware. This automatically solves the problem of firmware mismatch!

Iii. Upgrade Drive firmware

A maximum of four types of drive, irrelevant type, or different firmware versions can be updated at the same time!

When downloaddrive's firmware, all IO must be stopped, that is, the maintenance window

Do not download the firmware of both SATA and FC disks in the FC/SATA hybrid plug-in system !!! First download one type, then download another type

Iv. Upgrade Times

The following table lists the approximate time required to upgrade the firmware of each component. It is for reference only and can be used to arrange the maintenance window.

650) this. width = 650; "height =" 244 "border =" 0 "src =" http://img1.51cto.com/attachment/201301/22/731446_1358842397q55N.png "alt =" image "title =" image "style =" background-image: none; border: 0px none; padding-left: 0px; padding-right: 0px; padding-top: 0px; "/>

Attention: to ensure data security, Contact IBM Support for upgrade in the real Production environment!

Make an advertisement for a friend's shop-crocs canvas shoes

Http://item.taobao.com/item.htm? Spm = a1z10.1. w137712-596510807.2.67JcqB & id = 20993395165



This article is from the "star & storage" blog, please be sure to keep this source http://taotao1240.blog.51cto.com/731446/1124072

Related Article

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.