Lenovo Storage S3200/2200 stores can correct the order of IDs by scanning the disk channel again.
Re-scan to force a re-discovery of disks and cabinets in the storage system. If the two storage controllers are online and can communicate with the expansion modules in each connected cabinet, the re-scan will reconstruct the internal SAS layout information and re-allocate the cabinet ID of the connected cabinet based on the wiring sequence of the controller cabinet, make sure that the cabinets are displayed in the correct order. Manual re-scan will pause all I/O processes and resume normal operation. This will take two minutes to correct the cabinet ID.
You may need to manually rescan the cabinet after the system is powered on to display the cabinet in the correct order. When you change the drive rack or controller rack, performing a manual re-scan will force a re-discovery of all drive cabinets connected to the controller cabinet.
The procedure is as follows:
1. Confirm that the two controllers are running normally;
2. In the configuration graphic interface, right-click the main system directory and choose tools> rescan disk channel;
3. Click "rescan;