Scom 2012 knowledge sharing-7: understanding of detection signals

Source: Internet
Author: User

Platform: System Center 2012 RTM/SP1

Bytes ---------------------------------------------------------------------------------------------------------

System Center 2012-Operations Manager uses detection signals to monitor the communication channels between the proxy and the main management servers of the proxy. The detection signal is a packet sent regularly from the proxy to the Management Server. By default, the packet is sent every 60 seconds and port 5723 (UDP) is used ).

If the agent fails to send detection signals four times, an "Health Service detection signal failed" alarm is generated, and the Management Server attempts to ping the computer. If the computer does not respond to the Ping, an alarm "unable to connect to the computer" is generated. This process is displayed.

650) This. width = 650; "style =" border-top: # DDD 1px solid; border-Right: # DDD 1px solid; Background: URL ("/e/u261/lang/ZH-CN/images/localimage.png") No-repeat center; border-bottom: # DDD 1px solid; border-left: # DDD 1px solid; "src ="/e/u261/themes/default/images/spacer.gif "alt =" spacer.gif "/>

When you see these two alarms, you know that the Management Server cannot contact your computer. When you only see the detection signal failure alarm, you know you can contact the computer, but the agent has a problem.. When the detection signal returns to normal, both alarms are automatically disabled.

By defaultDisabled for the client operating systemLoss detection signals and Ping response alarms. To receive client OS alerts, replace the "Health Service detection signal failed" and "Computer inaccessible" monitors for Windows client OS, to set the "generate alert" parameter to "true ".

You can change the detection signal interval of all agents and the number of lost detection signals of all management servers in "Settings" in the "manage" workspace, as shown in.

650) This. width = 650; "Title =" image "style =" border-top: 0px; border-Right: 0px; Background-image: none; border-bottom: 0px; padding-top: 0px; padding-left: 0px; border-left: 0px; padding-Right: 0px; "Border =" 0 "alt =" image "src =" http://img1.51cto.com/attachment/201407/20/639838_1405815810gSrA.png "Height =" 348 "/>

The default interval is 60 seconds ,.

650) This. width = 650; "Title =" image "style =" border-top: 0px; border-Right: 0px; Background-image: none; border-bottom: 0px; padding-top: 0px; padding-left: 0px; border-left: 0px; padding-Right: 0px; "Border =" 0 "alt =" image "src =" http://img1.51cto.com/attachment/201407/20/639838_1405815811BkC3.png "Height =" 280 "/>

By opening the properties of your computer in "Agent Management" or "Management Server" in the "manage" workspace, youIt can also replace the global detection signal interval of a single proxy and the number of lost detection signals of a single management server.. For example, you can increase the interval of detection signals for computers with slow network connections.

650) This. width = 650; "Title =" image "style =" border-top: 0px; border-Right: 0px; Background-image: none; border-bottom: 0px; padding-top: 0px; padding-left: 0px; border-left: 0px; padding-Right: 0px; "Border =" 0 "alt =" image "src =" http://img1.51cto.com/attachment/201407/20/639838_1405815819b5Sf.png "Height =" 305 "/>

You can select "replace Global Proxy Settings" and modify a value ,.

650) This. width = 650; "Title =" image "style =" border-top: 0px; border-Right: 0px; Background-image: none; border-bottom: 0px; padding-top: 0px; padding-left: 0px; border-left: 0px; padding-Right: 0px; "Border =" 0 "alt =" image "src =" http://img1.51cto.com/attachment/201407/20/639838_1405815821aYv4.png "Height =" 605 "/>

Bytes ---------------------------------------------------------------------------------------------------------

This article is from the blog "Zeng luxin's technical column" and will not be reposted!

Scom 2012 knowledge sharing-7: understanding of detection signals

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.