How to solve the problem of IPMI monitoring hardware information inaccuracy in Zabbix??

Source: Internet
Author: User

In the Zabbix to obtain the hardware information in the IPMI way, Zabbix and Ipmitool get the information inconsistent (very big difference), how to solve this change?
Ps:ipmitool the information obtained is basically consistent with the HP ILO information, the above example is only normal temperature sensor, the rest of the basic is not normal. Solutions ...

[Root@zabbix zabbix]# ipmitool-i lanplus-h 192.168.2.85-uhpinvent-phpinvent SDR
UID Light | 0x00 | Ok
Sys. Health LED | 0x00 | Ok
Power Supply 1 | Watts | Ok
Power Supply 2 | Watts | Ok
Power Supplies | 0x00 | Ok
Fan 1 | 29.40 percent | Ok
Fan 2 | 29.40 percent | Ok
Fan 3 | 37.24 percent | Ok
Fan 4 | 37.24 percent | Ok
Fan 5 | 37.24 percent | Ok
Fan 6 | 14.11 Percent | Ok
Fans | 0x00 | Ok
Temp 1 | Degrees C | Ok
Temp 2 | Degrees C | Ok
Temp 3 | Degrees C | Ok
Temp 4 | Degrees C | Ok
Temp 5 | Degrees C | Ok
Temp 6 | Degrees C | Ok
Temp 7 | Degrees C | Ok
Temp 8 | Degrees C | Ok
Temp 9 | Degrees C | Ok
Temp 10 | Degrees C | Ok
Temp 11 | Degrees C | Ok
Temp 12 | Degrees C | Ok
Temp 13 | Degrees C | Ok
Temp 14 | Degrees C | Ok
Temp 15 | Degrees C | Ok
Temp 16 | Degrees C | Ok
Temp 17 | Degrees C | Ok
Temp 18 | Degrees C | Ok
Temp 19 | Degrees C | Ok
Temp 20 | Degrees C | Ok
Temp 21 | Degrees C | Ok
Temp 22 | Degrees C | Ok
Temp 23 | Degrees C | Ok
Temp 24 | Disabled | Ns
Temp 25 | Disabled | Ns
Temp 26 | Disabled | Ns
Temp 27 | Disabled | Ns
Temp 28 | Disabled | Ns
Memory | 0x00 | Ok
Power Meter | 188 Watts | Ok
CNTLR 1 Bay 1 | 0x01 | Ok
CNTLR 1 Bay 2 | 0x01 | Ok
CNTLR 1 Bay 3 | 0x00 | Ok
CNTLR 1 Bay 4 | 0x00 | Ok
CNTLR 2 Bay 5 | 0x00 | Ok
CNTLR 2 Bay 6 | 0x00 | Ok
CNTLR 2 Bay 7 | 0x00 | Ok
CNTLR 2 Bay 8 | 0x00 | Ok
650) this.width=650; "class=" Bde_image "src=" http://imgsrc.baidu.com/forum/w%3D580/sign= F8d586d1c91b9d168ac79a69c3deb4eb/e4da277f9e2f0708a62b3e0eee24b899a901f29a.jpg "height=" 299 "width=" 560 "alt=" e4da277f9e2f0708a62b3e0eee24b899a901f29a "/>

This article is from the "VIP" blog, please be sure to keep this source http://9472103.blog.51cto.com/9462103/1738108

How to solve the problem of IPMI monitoring hardware information inaccuracy in Zabbix??

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.