"Upgrade Step"
1. Motherboard BIOS to upgrade each blade first (current version I15 2009.07.10)
Reboot server required to complete upgrade
Upgrade method: Under Windows Double-click the downloaded EXE can.
Download Link:
Online ROM Flash Component for Linux (ESX)-HP ProLiant bl460c (I15) Servers
Online ROM Flash Component for windows-hp ProLiant bl460c (I15) Servers
2. Upgrade the ILO2 of each blade (current version 1.80)
Upgrade method
(1) Download and extract to a temporary directory
Download Link: Online ROM Flash Component for WINDOWS-HP integrated Lights-Out 2
(2) Enter the ILO2 management interface, select Administration→ilo 2 firmware,browse to firmware file (as shown in the following image), and press Send firmware image button.
(3) The ILO will be interrupted during the upgrade and the ILO will be restarted after the upgrade.
Note: The upgrade ILO has nothing to do with the server itself, without restarting the server