Z. Wang, W. Wu and B. Zhang, "A distributed Control Method with Minimum Generation cost for DC microgrids," inIEEE transactions on energy Conversion, vol. 4, pp. 1462-1470, Dec. 2016.
doi:10.1109/tec.2016.2584649
Keywords: {distributed control;distributed Power generation;power generation Control;power Generation Economics;power Grids;voltage control;dc Microgrid;bus voltage recovery;bus voltage regulation;communication delay;communication Link failure;distributed generator;energy Storage system;equal increment rate criteria;fully distributed control method; grid-connected mode;information exchange;islanded mode;minimal communication burden;minimum Generation Cost;neighbors ;p eer-to-peer communication;power balance;renewable Energy generation Utilization Improvement;sparse communication Network;subgradient algorithm; Capacitors;decentralized control; Generators; Microgrids; Peer-to-peer Computing; reliability; Voltage control;dc microgrid;distributed control;minimum generation Cost;subgradient algorithm},
url:http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7501580&isnumber=7753007
Q. Yu, X. Wang and Y. Cheng, "Electromagnetic Modeling and analysis of the Can Effect of a canned induction electrical machine , "inIEEE transactions on energy Conversion, vol. 4, pp. 1471-1478, Dec. 2016.
doi:10.1109/tec.2016.2602328
Keywords: {asynchronous machines;finite element Analysis;airgap flux distribution;analytical model;canned Induction Electrical machine;electromagnetic analysis;electromagnetic field;electromagnetic modeling;finite element method; Hydraulic pump drive;magnetic saturation; Electromagnetic modeling;hydraulic drives;induction motors;magnetic analysis;shielding},
url:http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7551136&isnumber=7753007
M. N. Ibrahim, P. Sergeant and E. E. Rashad, "Combined Star-delta windings to Improve synchronous reluctance motor Perf Ormance, "inIEEE transactions on energy Conversion, vol. 4, pp. 1479-1487, Dec. 2016.
doi:10.1109/tec.2016.2576641
Keywords: {machine windings;reluctance motors; SYNRM characteristics;combined star-delta winding;faulty conditions;healthy conditions;phase Fault;star wound machine; Synchronous reluctance motor performance Improvement;torque ripple; Coils; Finite element analysis;induction motors; Reluctance Motors; rotors; Torque; windings; Fem;modelling;performance;star-delta Connected windings;synchronous reluctance motor},
url:http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7485830&isnumber=7753007
G. Choi and T. M. Jahns, "Investigation of Key factors influencing the Response of Permanent Magnet synchronous machines T o three-phase symmetrical short-circuit faults, "inIEEE transactions on energy Conversion, vol. 4, pp. 1488-1497, Dec. 2016.
doi:10.1109/tec.2016.2594223
Keywords: {Finite element analysis;permanent magnet motors;rotors;short-circuit currents;synchronous machines; FE simulation; PMSM; SSC fault conditions;magnetic saturation effects;peak transient values;permanent magnet synchronous Machines;q-axis Prefault current;stator resistance;steady-state response;steady-state transient values;three-dimensional FE Simulations;three-phase SSC faults;three-phase symmetrical short-circuit faults;time-stepped finite element simulation ; transient response;two-dimensional FE simulations;demagnetization; Fault currents; rotors; Saturation magnetization; Steady-state; Transient analysis; windings; Concentrated;demagnetization;distributed;interior;permanent magnet;surface;synchronous;three-phase Symmetrical Short-circuit (SSC) fault;windings},
url:http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7523332&isnumber=7753007
C. Wang, P. Yang, C. Ye, Y. Wang and Z. Xu, "Voltage Control strategy for Three/single Phase Hybrid Multimicrogrid," inIEEE transactions on energy Conversion, vol. 4, pp. 1498-1509, Dec. 2016.
doi:10.1109/tec.2016.2595860
Keywords: {convex programming;distributed power generation;feedback;feedforward;linear matrix Inequalities;power Control;power generation Control;robust control;voltage control;control performance Optimization;convex optimization Problem;disturbance suppression;dynamic response Improvement;feedforward control;internal model compound control; Internal model robust Feedback Control;linear matrix inequality constraints;linear objective Functions;micro source OUTPU T power fluctuations;nonlinear loads;single phase hybrid Multimicrogrid;steady-state error reduction;three phase hybrid m ultimicrogrid;unbalanced loads;voltage control strategy;voltage output characteristics; Energy storage;inverters; Microgrids; Pi control; Power generation; Robustness; Voltage control; Compound control; H-infinity control;distributed generation;internal Model;multi-microgrid},
url:http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7536156&isnumber=7753007
Y. Song and F. Blaabjerg, "Wide Frequency Band Active damping strategy for DFIG System high Frequency Resonance," inIEEE transactions on energy Conversion, vol. 4, pp. 1665-1675, Dec. 2016.
doi:10.1109/tec.2016.2591779
Keywords: {asynchronous generators;damping;frequency response;high-pass filters;dfig System;high frequency resonance; High-pass Filter cutoff frequency;parallel compensated weak network;virtual Resistance;wide frequency band;wide Frequency band active damping strategy;damping;impedance;inductance; Power harmonic filters; Resistance; Resonant frequency; Rotors;dfig system Impedance;high Frequency resonance active Damping;high-pass filter;parameters design;virtual Resistance},
url:http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7513417&isnumber=7753007
J. Hu, Q. Hu, B. Wang, H. Tang and Y. Chi, "Small Signal instability of pll-synchronized Type-4 wind turbines Connected to High-impedance AC Grid During LVRT, "inIEEE transactions on energy Conversion, vol. 4, pp. 1676-1687, Dec. 2016.
doi:10.1109/tec.2016.2577606
Keywords: {eigenvalues and Eigenfunctions;electric current Control;modal analysis;phase locked Loops;power Supply Quality;power system Stability;wind turbines; ACC; LVRT; Pll-synchronized type-4 Wind turbines;alternating current control;deep voltage sag;dynamic model;eigenvalues; High-impedance AC grid;low-voltage ride through;modal analysis;phase locked Loop;small signal instability;stability Analysis;type-4 Wind turbines;impedance; Phase locked loops; Power system stability; Stability analysis; Voltage control; Voltage fluctuations; Wind turbines; Alternating current control (ACC); Lvrt;high impedance AC grid;interaction;phase locked loop (PLL); Small signal stability analysis},
url:http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7486001&isnumber=7753007
IEEE Trans on Energy Conversion 2