Ing EMC storage array to Media Server dc02 Server
1. Install EMC powerpath
Install powerpath on dc02.
1.1.1.1.1 configure the brocade optical fiber switch
The MOD data center has two switches (Top, bottom), one server dc02 and one EMC. The topo diagram is as follows:
Therefore, all connections are optical fiber connections.
Requirement: allocate bak01 and top switch in a zone.
Step 1: Login to top switch
Step 2: Collect the device WWN on the port
Top_sw: Admin> portshow 8
Portwwn: 20: XX: xx
Portwwn of device (s) connected:
10: 00: XX: xx
Create alias
Top_sw: Admin> alicreate "bak1", "20: XX"
Spa: top_spa
SPB: top_spb
Create Zone
Top_sw: Admin> zonecreate "top_bak01_zone", "bak1; top_spa; top_spb"
Add the current zone to the existing configuration
Top_sw: Admin> Add "main_config", "top_bak01_zone"
Activate zone Configuration
Top_sw: Admin> cfgenable main_config
Save zone Configuration
Top_sw: Admin> saved save
1.1.1.1.2 install the manager agent
1. Click naviagent.exe to install the tool.
2. Create an agentid.txt file in C:/program filesemc/manager agent. Add two lines in the file. The first line is the host name, and the second line is the Host IP address.
3. Run agentconfiginit.exe in C: Program filesemcmanager agent. Select create/overwrite file and click Add. A dialog box is displayed. Enter system after user name and spa IP address after system name. Click Add to add the SPB information. Click OK to save.
4. You can view the configuration file of agent. config as follows:
Clardescr
Clarcontact
Poll 60
Baud 9600
EventLog 2048
User system@203.110.xxx.xxx
User system@203.110.xxx.xxx
5. Restart the agent service.
1.1.1.1.3 map lun to bak011.1.1.1.3.1 create a group for server bak01
1.1.1.1.3.2 map bak01
Step 1) scan new hardware
Step 2) format new partition
Step 3) powerpath state