Integrated Wiring System Standard full manual

Source: Internet
Author: User

There are many things worth learning about Integrated Wiring System standards. Here we mainly introduce factors affecting bandwidth and temperature effects, including 6 and 5 standards, let everyone have a more comprehensive understanding of the wiring standards. Channel bandwidth is one of the most important parameter indicators for judging communication and wiring performance. The bandwidth size is affected by environmental factors, and the most influential factor is temperature.

In a copper cabling system, the bandwidth is usually expressed by the bandwidth of A-meter twisted pair channel in MHz. Channel bandwidth refers to the channel frequency range without changing the signal-to-noise ratio. The difference between the next-generation standard, for example, Category 6 or category 7, and the original low-level integrated wiring system standard lies in the difference in available (effective) bandwidth. The relationship between Bandwidth and information transmission capability was discovered by cldeshannon a long time ago. This rule is called Shannon's law. In general, higher bandwidth in the cabling system means higher data transmission rates.

There is a basic relationship between the channel bandwidth measured in MHz and the information transmission capability or data transmission rate measured in Mb/s. You can use the traffic flow of the main highway to describe the relationship between Bandwidth and data transmission rate. The bandwidth can be used as the number of lanes on the expressway, and the data transmission rate can be used as the traffic or the number of vehicles passing through each hour. One way to expand traffic is to widen the expressway, while the other is to improve road surface quality and eliminate bottlenecks. Similarly, it is possible to enable each Hz frequency in the available bandwidth to carry more information bits, but this requires a better signal-to-noise ratio.

Today, most LAN systems need to control the noise source from the near-end crosstalk between the transmission line pair and the receiving line pair. When all the nearby crosstalk sources are taken into account, the signal-to-noise ratio measured in decibels is the same as the cumulative power attenuation crosstalk ratio (PSACR. The advantage of the six standards is that the cumulative power attenuation crosstalk ratio (PSACR) is controlled within the frequency range of MHz bandwidth within a range greater than zero, the available bandwidth can be twice the standard of the five generic cabling systems.

Factors Affecting bandwidth
A Class 6 standard channel should be designed to have lower signal attenuation and better near-end crosstalk characteristics than Class 5 standard channels. Lower signal attenuation can be achieved through the use of copper media cables of a slightly heavier specification, with a diameter between 0.5mm (24AWG) and 0.6mm (23AWG. Two available cables are included in the scope of TIA's 6 standard specifications. At MHz bandwidth, the signal attenuation of these six types of cables is nearly 2 dB and 4 dB lower than that of the five types of cables. In the same MHz bandwidth, the two types of 6 cables are nearly 12 to 18 decibels lower than the near-end Crosstalk of the five types of cables.

Temperature Effect
Signal Attenuation of cables is greatly affected by temperature. Each time the temperature increases by 10 degrees Celsius, the signal attenuation of the cable increases by 4%. This means that the signal attenuation of the 92.6-meter cable at 40 degrees Celsius is the same as that of the 100-meter cable at 20 degrees Celsius. Therefore, the effect of temperature on signal attenuation is much greater than that of many other environmental factors.

The effect of temperature on bandwidth is so significant. The bandwidth values of enhanced 5 generic cabling systems and 6 generic cabling systems under different temperatures are compared. Cables are usually installed in a place with high ambient temperatures such as ceiling and air duct. A recent study by the University of California's Lawrence Berkeley National Laboratory showed that the temperature of Exhaust pipes in many steel-concrete buildings can reach 49 degrees Celsius in the Midsummer season. However, the temperature of cables may be high in factories and other environments.

We advocate the use of low-attenuation cabling systems to meet the requirements of 6 generic cabling systems to reach the target bandwidth of MHz at a reasonable minimum temperature of 40 degrees Celsius. IBDN4800LX is a new generation of six types of cables to meet this requirement. It provides highly scalable channel bandwidth and supports transmission rates up to 4.8 Gb/s, in addition, it overcomes the problem of reducing system performance in a high-temperature environment and provides a satisfactory response to ieee lan device developers.

  1. Summary of Integrated Wiring construction experience
  2. The Integrated Wiring market is "competing for better ideas"
  3. Adhere to the sustainable development of data center cabling systems
  4. Deploy the "green" Data Center cabling system to the end
  5. Optimal Integrated Wiring solution in history

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.