Introduction to the 4.1 INI file:
4. 1. 1[of the RF function Group]
The following are the items defined in the Setup INI file.
GSM900 Sig = 1
GSM1800 Sig = 1
GSM1900 Sig = 1
GSM900 NSig = 1
GSM1800 NSig = 1
GSM1900 NSig = 1
Usually set to 1, which means that the device is reset before the CMU200 is set to zero 0 o'clock.

4. 1. 2 system settings:
Items defined in the Setup INI file:
External Reference Clock = 0 The default value is 0, which refers to the reference clock using the CMU200 output, which is 1 when used
external reference clock.
CMU Base GPIB Address = 20
The GPIB address of the CMU is set to correspond to the software.
instrument = "CMU200"
The device used is CMU200
Power Supply Address = Gpib0::5::instr
Setting of the Power address
When using kei230x, Power supply Address = 5 should be used
CMU RF Port = 2
RF port settings used by the CMU200
Test Mode = 0
Set to 0 refers to the need to manually initialize the device, 1 refers to the software will automatically initialize the device at the time of the test, 2 means
On-time on-school software will automatically initialize the device, 3 refers to the calibration and testing joint test software will automatically
To initialize
FDM database File = "C:\Program Files\mtk_atedemo\report\bplguinfocustom"
The storage path of database file must correspond to the phone software
Calibration file = "C:\Program files\mtk_atedemo\mtkcal_6205b. INI "
Calibrate the path to the initial default settings file
Config file = "C:\Program files\mtk_atedemo\meta_6205b. CFG "
About calibration settings, such as calibrated channel, limit maximum, minimum value
Report File Path = "C:\Program files\mtk_atedemo\report_6218b"
Storage path for test reports
Database file = "C:\Program Files\mtk_atedemo\report_statistics\6218b_statistics.xls"
The storage path of the test result file
IMSI = "001010123456789"
Settings for the IMSI number in the SIM card
POWER on After change = 1
Set to 1 if the device changes in a different state when the joint test is slow
Stability Count = 1
Number of cycle tests set
Fixture COM port = 1
Serial Address settings
System Cable Loss calibration = 0
Line loss selection for calibration system

4. 1. 3 Call setup setting
Setup network = 1
Setting up a call, 1 refers to the GSM band, 2 refers to the DCS band, and 3 refers to the PCS band
GSM call setup channel = 1
to establish the channel number setting for calls
GSM BCCH channel = +
Broadcast control channel Settings
DCS call Setup channel = Up
DCs set up channel settings for calls
DCs BCCH channel = + Settings for the broadcast control channel
PCs call setup channel =
PCs set up channel settings for calls
PCs BCCH channel = $
Settings for the PCS broadcast control channel
GSM850 calling Setup Channel = +
GSM850 set up the channels for the call
GSM850 bcch channel = +
GSM850 broadcast control channel settings
BCCH RF level = -60
Downlink broadcast control channel levels
bs TCH level = -80.5
Base Station service channel levels
Triple Band = 0
Test for PCS when set to 1
DCs Band = 1
1 refers to test DCS
GSM Band = 1
for 1 refers to the test GSM Band = 0
for 1 o'clock, GSM850
GPRS test = 0
is 1 for GPRS testing

4. 1. 4 Signaling Test
Power measment Burst = 10
The number of Burst to be measured when defining a power test
Average Burst Power = 1
1 refers to the test for average power
Peak Burst Power = 1
1 refers to the test for peak power
PVT Match = 1
Power Time template test for 1 fingers
Modulation Measment Burst = 10
Defines the number of Burst to be tested when modulating spectrum testing
Phase Error Peak = 1
1 refers to the test for phase peak error
Phase Error RMS = 1
1 refers to the test for the error of the phase mean square value
Frequency Error = 1
1 refers to the test for frequency error
ORFs MOD Burst = 10
The number of Burst to be tested when defining a modulation spectrum test
Spectrum modulation = 1
1 refers to the test for the modulated spectrum
ORFs Switch Burst = 10
Defines the number of Burst to be tested when switching spectrum testing

Most detailed information: MTK Calibration Profile parameter detailed description download

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.