Pulsonix high-speed cabling-snake cabling
It is not supported in version 6.0, but it does not rule out the issue of cracking or plug-ins. It is available in version 7.6.
A. In setup-> technology, select nets-net classes in the list box, and click New to create a new net class.
The purpose is to configure the rules for snake-like cabling.
In the figure, the unit is mil.
Parameter description:
Mitre shape: choose whether to splice the inflection point or curve, 180 degree curve (180 degree arc), octagonal (octagonal), user defined
Curved: whether to use arc stitching.
Mitre ratio: 1 indicates the arc of 180 degrees, and 0.5 indicates the arc of 90 degrees.
Additional length: Except for a straight line, the total length of the snake line. If not selected, the longest snake line will be placed in the space, that is, the snake line has
The physical limit value is invalid if the value you set exceeds the limit value.
B. Draw a snake line
You can also perform a snake line between the via and pin.
Draw a line between the pin, select the line to be taken, right-click the line, and select smooth selected track in the pop-up menu to smooth the line,
I don't know why I want to smooth the cabling. The result of my experiment is that if the cabling is not smooth, it won't be able to draw a snake-like cabling,
Right-click and selectSerpentine selected segments, displays your set snake line
C. Delete the snake line
Click any section of the snake-like online and press the delete key.
D. Modify the snake line
Click any section of the snake-like line, hold down the left mouse button, drag and drop the line segment, press shift, and select any segment of the snake-like line,
Select the entire snake line, right-click it, and select Properties from the pop-up menu to view the length of the snake line. The length is
The length of the snake, rather than the total length of the curve.
========================================================== ======================================
Http://download.csdn.net/detail/osoon/4979146