Purchase of cabling products in Smart Home

Source: Internet
Author: User

Purchase of core cabling Products

1. Information Access box and entry

According to the principle of standardized integrated home wiring, all the external incoming cables and the outlets of each terminal port should be in the Information Access box. Therefore, the core of the home wiring system is the Home Information Access box. Products separated by cabinets and modules should be used. The module standard 1U is a general module, and users should try to adopt standardized products. In this way, the functional modules are highly selective, changeable, and can be upgraded, scalable. Weak Current signals are most vulnerable to interference. Therefore, the dual-shielded structure (the outer iron box is shielded, and each module in the inner layer is independently shielded) must be considered to completely solve the interference of weak current external and internal lines. Boxes that have passed the Ministry of Information Industry inspection and certification should be selected. Large enough space to facilitate the installation of broadband routers and switches. In addition, the information box cannot have a strong power supply, but can only be introduced by external power supply low voltage.

SIMON Electric's multimedia information receiving box uses high-quality materials. The first consideration is to meet the security requirements of home life. The beautiful appearance and complete specifications provide convenient options for different living environments and home structures. Function configuration consists of data ports, telephone branches, TV modules, audio and video sharing, monitoring modules, switches, hubs, and extended interfaces, functions mainly include access, allocation, transfer and maintenance management. The series of multi-family cabling products, including S, M, L, and B, can basically meet the requirements. For general families, use the S (small) and M (medium) types. ()

The following (1)-(3) is the three basic "Three Network" cables that come standard with SIMON Electric's multimedia information access box. It is also the required information access box module in common home wiring, others are selected by the user. The details are as follows:

(1) data port entry (SNBT-SJ6 )()

Six interfaces, five types of RJ45 interfaces, and no cabling module. Complies with ISO/IEC11801, TIA/EIA568A or 568B standards. Cables for information points that provide online services are allocated to the six data modules of the functional component. Then, use the network jumper to connect the switch ports of the Self-small switch or Broadband Router to the RJ45 ports on the module.

Voice Record (SNBT-GX7 )()

1-in-7 shared phone branch, 5-class RJ45 interface standard, used for 1-in-7 phone connection. The telephone lines are connected in parallel. One of the two calls can be listened to by another phone.

(3) video record (SNBT-DS4 )()

Provides a one-to-four cable TV distributor, F-type coaxial cable connector (75 ohm), 5 MB ~ 1000MHz broadband. Used for cable TV access and distribution.

(4) Audio and Video Record ()

Consists of four audio and video screw lines from 1 to 3, each of which is controlled by the corresponding switch. Connect the input signal line and output signal line (R: right channel, L: left channel, V: Video) to the brass screw line and tighten the screw respectively. There are three groups of three small switches on the panel, respectively controlling the switching of the three sets of output signals. You can close the corresponding switches as needed. It can be used in multiple rooms to share the audio and video playback of a VCD/DVD, as well as the connection between the rear Speaker of the home theater and background music.

(5) access control signal acquisition record ()

This feature provides 12-way RVV soft line conversion and brass Screw Pressure interface, which can be used as an intermediate contact for information such as doorbell, intercom, and home access control.

(6) Monitoring bar for collecting meter reading signals for security alarms ()

This feature provides 10-way twisted pair wire transfer and 110-card interface, which can be used as an intermediate contact between security, fire and other equipment and water, electric, gas, and hot meter reading systems. A dedicated cabling tool is required to break the external line into the digital card mouth, and then the line connecting the internal device into the corresponding card mouth.

(7) Monitoring metrics (figure 8)

The monitoring signal feature is a set of high-quality dual-pass bnc rf Coaxial Connectors (75Ω) that are used to connect visual and monitoring probes. Connect the indoor and outdoor cables to the attached "L" type BNC connector respectively, and then connect them to the two ends of the same group of BNC connectors of the functional component.

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.