For network management, QoS function settings of Huawei routers are usually used for IP Address Configuration in route settings. To better understand the configuration process, we will take Huawei routers as an example today, I will give you a detailed introduction. QoS has two parameters: upstream bandwidth and downstream bandwidth. the uplink bandwidth and downstream bandwidth can be understood as the actual downstream bandwidth of the bandwidth line applied by the user, you must first enable QoS and fill in the actual upstream and downstream bandwidth of the line before continuing configuration on the IPQoS page. Otherwise, an error is prompted.
1. The CIDR block contains a total of 11 IP addresses from 10 to 20. The CIDR Block allows you to enter IP addresses that are not in the same CIDR block as the IP address of the router LAN port, if the Intranet uses a layer-3 switch device to plan different subnets, Our routers can also support bandwidth restrictions on IP addresses of different network segments. 2. mode independent bandwidth. the maximum and minimum bandwidths below are for each IP address in this IP address. If the mode is shared bandwidth, It is the parameter below the IP address sharing.
Iii. restrictions are imposed on the separation of upstream and downstream data streams on routers. If the computer with the IP address 192.168.1.10 is in P2P download, the data traffic on this computer will be relatively large, the data flow of this computer is divided into two parts: one is that it downloads data from another server, and the other is that it uploads data to another computer, the IP QoS of the vro limits the data traffic in both download and upload directions. The computer at www.2cto.com provides a minimum data traffic guarantee of 50 Kbps and a maximum bandwidth of 100 Kbps. The minimum downstream data traffic guarantee is Kbps and a maximum bandwidth of Kbps. The available bandwidth of upstream and downstream data is based on the actual/downlink bandwidth of the line.
Iv. configuration steps
1. Manually specify the IP address of the computer on the Intranet, which is continuous, for example, 192.168.1.2 ~ 192.168.1.100 to facilitate subsequent settings; 2. Set the bandwidth of your line in the ip qos settings switch, and set the uplink bandwidth and downlink bandwidth of the line respectively, for example, enter 10000 for a 10 m optical fiber line, and enable the QOS master switch. 3. Go to the ip qos rule settings page and add a new entry. Set the IP address segment, for example, 192.168.1.2 ~ 192.168.1.100, the mode is set to independent; the uplink minimum bandwidth: the actual uplink bandwidth of the line/The number of Intranet computers. In this example, the uplink minimum bandwidth is 10000/99 = 101. The maximum bandwidth has little to do with the setting, it is recommended to set 800, 1000, or 2000; downlink minimum bandwidth: the actual downlink bandwidth of the line/The number of Intranet computers. In this example, the value is 10000/99 = 101. The maximum bandwidth does not matter, we recommend that you set 800, 1000, or 2000. 4. Save the settings. The preceding steps describe the QoS function of the Huawei router for IP addresses. For more information, see.
This article is from