 disp cur #! Software Version v200r001c00spc300 sysname DRAGONSW # FTP server enable # VLAN batch 2 to 3 # HTTP server load S5700SI-V20 0r001c00.001.web.zip # undo Nap slave Enable # VLAN 2  description server-room VLAN 3  description Office # AAA  authentication-scheme default  authorization-scheme default  accounting-scheme default  domain Default  domain default_admin  local-user admin password cipher%$%$ #M ' v$i. ' u#5+ag&3qa3mysja%$%$   Local-user admin Privilege Level  local-user admin service-type telnet Terminal ssh Web http # interface VLANIF1 & Nbsp;ip address 172.0.3.254 255.255.254.0 # interface Vlanif2  description 172.0.0.0-172.0.3.255 &NBSP;IP address 17 2.0.1.254 255.255.254.0 # interface Vlanif3  description 172.0.8.0-172.0.11.255 &NBSP;IP address 172.0.8.254 255.255.252.0 # interface METH0/0/1 # interface GIGABITETHERNET0/0/1  port link-type Access # interface Gigabitethern ET0/0/2  port link-type Access # interface GIGABITETHERNET0/0/3  port link-type Access # interface GIGABITETHERNET0/0/4  port link-t ype Access # interface GIGABITETHERNET0/0/5  port link-type Access # interface GIGABITETHERNET0/0/6  port link-t ype Access # interface GIGABITETHERNET0/0/7  port link-type access  port default VLAN 2 # interface Gigabitether NET0/0/8  port link-type access  port default VLAN 2 # interface GIGABITETHERNET0/0/9  port link-type acces s  port default VLAN 2 # interface GIGABITETHERNET0/0/10  port link-type access  port default VLAN 2 # inte Rface GIGABITETHERNET0/0/11  port link-type access  port default VLAN 2 # interface GIGABITETHERNET0/0/12   Port Link-type Access  port default VLAN 2 # interface GIGABITETHERNET0/0/13  port link-type access  port D Efault VLAN 3 # interface GIGABITETHERNET0/0/14  port link-type access  port default VLAN 3 # interface Gigabite THERNET0/0/15  port Link-type Access  port default VLAN 3 # interface GIGABITETHERNET0/0/16  port link-type access  port Defau Lt VLAN 3 # interface GIGABITETHERNET0/0/17  port link-type access  port default VLAN 3 # interface Gigabitether NET0/0/18  port link-type access  port default VLAN 3 # interface GIGABITETHERNET0/0/19  port Link-type acc ESS  port default VLAN 3 # interface GIGABITETHERNET0/0/20  port link-type access  port default VLAN 3 # in Terface gigabitethernet0/0/21  port link-type access  port default VLAN 3 # interface GIGABITETHERNET0/0/22 &nbs P;port link-type access  port default VLAN 3 # interface GIGABITETHERNET0/0/23  port link-type access  port Default VLAN 3 # interface GIGABITETHERNET0/0/24  port link-type Access # interface NULL0 # snmp-agent snmp-agent Lo Cal-engineid 800007db034846fb898260 snmp-agent sys-info location Xiamen China snmp-agent sys-info version v3 # User-interf Ace Con 0  authentiCation-mode Password  set authentication password cipher%$% $oZ [ocm0gjbl,0z<+kdtc,90 ' nsc,wzzy4%[0<j~o< div= "" > Xf+r "~61%$%$ user-interface vty 0 4  authentication-mode AAA user-interface vty # return   Rebo OT info:the System is now comparing the configuration, please wait. Info:if want to reboot with saving diagnostic information, input ' N ' and then e xecute ' reboot save Diagnostic-informatio N '. System would reboot! Continue? [Y/n]:y Oct  1 00:19:00-05:13 dragonsw%%01cmd/4/reboot (l) [29]:the user chose Y whe N deciding whether to REBOOT The system. (Task=co0, ip=**, user=**) Info:system is rebooting, please wait ... OCT  1 00:19:00-05:13 DRAGONSW%%01srm/4/mstrscurst (l) [30]:master SCU is re set. OCT  1 00:19:00-05:13 DRAGONSW%%01srm/4/resetreason (l) [31]:board Reset by VRP command or Net Manager. System reboot at 00:19:01   BIOS LOADING ... Copyright (c) 2008-2011 HUAWEI TECH CO., Ltd. (Ver162, May, 10:56:32) current Flash FS:DOSFS flash:/ -Volume is OK     Press Ctrl+b to enter bootrom menu ... 1Password
v100r006 Previous version password is: Huawei, after the version password is: Admin@huawei.com Bootrom MENU 1. Boot with default mode 2. Enter Serial submenu 3. Enter Startup submenu 4. Enter Ethernet submenu 5. Enter FileSystem submenu 6. Modify bootrom Password 7. Clear password for console user 8. Reboot Enter Your choice (1-8): 7 note:clear password for console user? Yes or No (y/n): Y
Clear password for console user successfully. Choose "1" to boot and then set a new password. Note:do not choose "8. Reboot "or power off the device, otherwise this operatio n won't take effect.             bootrom  menu       1. Boot with default mode     2. Enter Serial submenu     3. Enter Startup submenu     4. Enter Ethernet submenu     5. Enter FileSystem submenu     6. Modify bootrom password     7. Clear password for console user     8. Reboot   Enter Your choice (1-8): 2             SERIAL  submenu     &NBSP ; 1. Update bootrom system     2. Download file to Flash through serial interface     3. Modify Serial Interface parameter     4. Return to main Menu   Enter your choice (1-4): 4             Bootrom  menu   & nbsp   1. Boot with default mode     2. Enter Serial submenu     3. Enter Startup submenu     4. Enter Ethernet submenu     5. Enter FileSystem submenu     6. Modify Bootrom password     7. Clear password for console user     8. Reboot   Enter Your choice (1-8): 3          startup Configuration submenu     &NBS P 1. Display Startup configuration     2. Modify startup configuration     3. Return to main Menu   Enter your choice (1-3): 3             Bootrom  menu   & nbsp   1. Boot with default mode     2. Enter Serial submenu     3. Enter Startup submenu     4. Enter Ethernet submenu     5. Enter FileSystem submenu     6. Modify bootrom password     7. Clear password for console user     8. Reboot   Enter Your choice (1-8): 4             ETHERNET  submenu     &NB Sp 1. Update bootrom system     2. Download file to Flash through Ethernet interface     3. Upload Configuration file to FTPThrough Ethernet interface     4. Modify Ethernet Interface Boot parameter     5. Return to main Menu   bes sure to select 4 to modify boot parameter before downloading! Enter your choice (1-5): 5             bootrom  menu       1. Boot with default mode     2. Enter Serial submenu     3. Enter Startup submenu     4. Enter Ethernet submenu     5. Enter FileSystem submenu     6. Modify bootrom password     7. Clear password for console user     8. Reboot   Enter Your choice (1-8): 5            filesystem submenu       1 . Erase Flash     2. Format Flash     3. Delete file from Flash     4. Rename file from Flash     5. Display Flash files     6. Update EPLD file     7. Return to main Menu   Enter your choice (1-7): 7     &NBSP;       Bootrom  menu       1. Boot with default mode     2. Enter Serial submenu     3. Enter Startup submenu     4. Enter Ethernet submenu     5. Enter FileSystem submenu     6. Modify bootrom password     7. Clear password for console user     8. Reboot   Enter Your choice (1-8): 2             SERIAL  submenu     &NBSP ; 1. Update bootrom system     2. Download file to Flash through serial interface     3. Modify Serial Interface parameter     4. Return to main Menu   Enter your choice (1-4): 4             Bootrom  menu   & nbsp   1. Boot with default mode     2. Enter Serial submenu     3. Enter Startup submenu     4. Enter Ethernet submenu     5. Enter FileSystem submenu     6. Modify bootrom Password &NBsp   7. Clear password for console user     8. Reboot   Enter Your choice (1-8): 7   note:clear password for console user? Yes or No (y/n): Y   Clear password for console user successfully. Choose "1" to boot and then set a new   password. Note:do not choose "8. Reboot "or power off the device, otherwise this operatio n won't take effect.             bootrom  menu       1. Boot with default mode     2. Enter Serial submenu     3. Enter Startup submenu     4. Enter Ethernet submenu     5. Enter FileSystem submenu     6. Modify bootrom password     7. Clear password for console user     8. Reboot   Enter Your choice (1-8): 1   loading[flash:/s5700si-v200r001c00spc300.cc] ...... Update Epld file ......... ............ None of the decompressing VRP software .... Done    disk cache flush and Invali (NO)Date ... OK USB2 Host Stack Initialized. USB Hub Driver Initialized USBD  wind River Systems, Inc. Initialized EHCI Controller found. Waiting to attach to USBD ... Done. Usbpegasusendinit () returned OK   current Flash Fs:dosfs 0x6effe68 (troottask): Usbbulkdevinit () returned OK   Cpu:marvell XCat 98dx4122.  processor #1. Memory Size (for VxWorks): 111M. Bootrom version:162 Epld version:ver 5 Creation date:jul, 05:29:16   Wdb:ready.   flash:/ -Volume is OK, there is no record in region Exception.   PPI DEV sysinit ....., ....... OK   VRRP cmd disable ... BFD cmd Disable ... Hard System init ........ ..... OK Begin to start of the system, please waiting ...   VOS VFS init ....... ......... OK Startup File Check ...... ..... OK Paf File Read ......... ..... OK VOS Monitor init ....... ..... OK CFM init advance ....... ..... OK PAT init ........... ....... OK HA s2m init ......... ....... OK VOS VFS INit hind ......... OK   Vrp_root begin ... Vrp_initializetask begin ... Init the Device Link ....... Ok? Cfg_planeinit begin ..... ..... OK cfm_init begin ......... ..... OK cli_cmdinit begin ....... ..... OK vrp_regestalllinkcmd begin .... OK Create task begin ..... task init begin ...   cmd register begin ... cmd register end ...   Recover Co., ..... Nfiguration ... Ok! Press ENTER to get started.   An initial password are required for the first login via the console. Set a password and keep it safe! Otherwise you are not being able to login via the  console. Reset the console passwordPlease configure the login password (maximum length 16) Enter Password: Confirm Password:Quit

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.