Tempo dini03/lycra DNA03 and other electronic leveling instrument raw data compilation software

Source: Internet
Author: User
Tags first row time interval
1. Software Introduction

The types of simulation data supported by the software include: Tempo, Levin, Sokkia, Middle latitude, South DL and other digital leveling data. Engineering Monitoring Technical Communication QQ Group: 452847739, will provide continuous software updates and notifications. Software author qq:3339745885, any questions about the software are welcome to consult the author. software Download link : Https://pan.baidu.com/s/1nwEwwYX password: jeme, the latest version of the software is:2.8.6.0. Software Youku Video Tutorial:
http://v.youku.com/v_show/id_XMzIxNjA3OTAzNg==.html?spm=a2hzp.8244740.0.0

The software based on the existing point elevation, distance preparation level of the original observation data*. Dat. GSI, etc.Format data, is a tool for auxiliary monitoring work. The software is named:Tempo dini03/lycra DNA03 raw data simulation 2.8.6.0.exe2.8.6.0is the version number.1.1 main FunctionsCan simulate the BFFB, BF, BBFF, ABFFB measurement mode of the tempo of the original data, support the simulation of a variety of intermediate point method (Fulcrum) measurement mode, support to simulate a number of horizontal lines, and set the start time, time interval, error rate, etc., in the Toolbox, Tools that provide GSI-8 or GSI-16 data to DAT, also support dat to GSI-8 or GSI-16 data, tools for removing time or adjusting time for temperature in the toolbox, inverse adjustment (station or ranging), can be recovered to submit the original data corresponding to the report, to be able to BFFB,BF, The BFBF,BBFF,FBBF,BBFF,BF contains the raw data of the intermediate point converted to Cosa's in1 format data and the southern adjustment easy data, and filters the turn points according to the set conditions; Generate leveling book (the original record containing the center point); be able to automatically organize the template from the original data; Level Data dat direct adjustment (measuring station or distance); batch processing, reading Excel template, batch generation DAT data, and can batch to the GSI data, support simulation long-distance (dozens of km) level data, and can set the rest time; Support simulation of the standard level of the standard data simulation (simulation of the tempo data, and then use the software to turn the tool into a medium-dimensional data); Support analog cable leveling level data simulation (first simulation of the tempo data, and then use the software to bring the tool into the good data); Support format for DAT format: BF,BFFB, ABFFB mode of measurement data to the GSI, but does not support the ABBFF with the middle point mode, support the fixed instrument height (depending on the axis height) monitoring the surrounding level (BFFB and other monitoring mode), that is, the front of a measuring station and the next station after the view ruler reading the same. Modify the file time. Modify the data file time generated by the simulation to the time you want to set it. (The file path requires non-Chinese.) Dat2dat functionality that directly enables the ability to recover multiple sets of DAT data through a DAT data. supports the creation of separate segments of DAT files for multiple segments in DAT files. Supports custom before and after visual range. Support simulation of the southern Digital leveling data (simulation of the tempo data, and then use the software to bring the tool into the south level data). Support Batch DAT data generation data template, support to generate DAT data based on batch data template. Supports converting the GSI16 format to the GSI8 format. Supports the generation of optical leveling data.

Software is powerful, there is no place to welcome the author qq:3339745885 Consulting. 1.2 Software Downloads

Link: Https://pan.baidu.com/s/1nwEwwYX Password: jeme. It is useful to download all the contents of this link.
64-bit system: Download all content from the "Tempo dini03/lycra DNA03 original data simulation software (x64)" file.
32-bit system: Download all content from the "Tempo dini03/lycra DNA03 original data simulation software (x86)" file.

1.3 Software Installation

System requirements: Windows XP/WIN7/WIN8/WIN10, not relying on Office software.
Take a 64-bit system installation as an example: Open the " tempo Dini03 lycra DNA03 raw Data simulation software (x64)" folder to find Vcredist_x64.exeand open the software after installation Tempo Dini03 lycra DNA03 raw Data simulation 2.8.6.0.exe .

Take a 32-bit system or XP system installation as an example: Open the " tempo Dini03 lycra DNA03 raw Data simulation software (x86)" folder, locate, install Vcredist_x86.exe and then open the software Tempo Dini03 lycra DNA03 raw Data Simulation (X86). exe is used. 1.4 Software Main interface

Basic parameter Settings Select Default.

2. Instructions for use of the software

The software cannot generate data from a thin air, and the data template is required to simulate data. Some data templates exist in the directory where the software is located, and you can use your own template to learn how to use the software. Then make your own template based on your own template and template production instructions. 2.1 Data Template explanation

In the Open folder: Test _ data _ template. xlsx file, modify the name, distance s, attributes, elevation information according to the following rules. The first row point ZQC01 has an elevation of 144.2137, which is the base elevation point with a known elevation of 144.2137. The last measurement end, closed or echoed to the elevation point ZQC01 or other points. Closed or conforming to the end point of the route as a known point and the remainder as the point to be measured.
The exact meaning of the template, see the full description in section 2.2.


Closed route Template

Attach route template

If you want to fit multiple levels into a DAT file, you need to add line to the point name, so that the resulting template can simulate multiple levels in the same DAT file. If you only need a level route, you do not need line separation. The following figure is the data template in Excel.


Multi-level course templates

Batch processing templates

2.2 Template Production detailed



Level map (including monitoring points and points, and intermediate points in the monitoring points)

The first column of the template, the name with the actual name input, the turn point name can all use 1 (the software will automatically identify the point named 1, rename it to the point zd1,zd2,zd3 .... The "ZD" string can be set to any letter or number in the software interface, and the settings can be customized by the roll name. The second column of the template, the data is the distance between two adjacent points, the distance is approximately equal to the front and rear view distance and (the line distance, approximate row). The software will automatically split this distance, as a front and rear view distance. The distance from the beginning ZQC01 is 0 m (or any, the software does not use this distance, but cannot be empty). The third column of the template, the normal level point attribute is none, the property of the transpose point is None, the attribute of the midpoint is Z, here Z is the first letter of the Zhong (middle), the non-rotating point. If you don't know what the middle point is, all of the points ' properties are named None. The fourth column of the template, enter the elevation of the monitoring point (5 decimal places). Depending on the need, several points can be interpolated between adjacent monitoring points (that is, points on the leveling line), and the software is automatically inserted into the turn point function. The height difference of each station cannot be too big, if too big can not simulate the data. There are 3 ways to solve the problem: 1) You can add a turn point, transition elevation, 2) turn down the minimum reading of the ruler or increase the maximum reading, but to meet the level requirements; 3) Select the Auto Add Point function in the software interface. If making a template is more troublesome, you can get the template file by using the tools in the toolbox directly from the original data (DAT) that you obtained earlier, and the DAT will be turned into a template for simulation data.
First open DAT data, then click the "Generate Data Template" tool in the toolbox.

2.3 Data Simulation

Use the software to open the test _ data template. xlsx file, click the Simulate button to start the simulation data.


Currently the software only recognizes templates in Excel (xlsx) format, and other format simulations will result in errors.

2.4 Introduction to three simulation modes of intermediate point method

The intermediate point measurement mode, which only affects the simulation of the middle point, has no effect on other points on the leveling route, that is, only the point where the attribute is Z (attribute z is not the point of the turn, the attribute of the turn point is none), and there is no effect on the point where the attribute is none.

Mode I: After setting up the instrument, first measure the level of the level line (such as: Point zqc03-point 1), and then measure the intermediate points (such as: ZJD11, ZJD12 ...), and then move to the station. Take BFFB model as an example, that is, bffb-intermediate point;


bbff-Middle Point

Mode II: When the instrument is set up, the intermediate points (e.g. ZJD11, ZJD12 ...) are measured, then the points on the level route (e.g., zqc03-1) are measured, and then the station is moved. That is, the middle point-BFFB, Mode II is rarely seen, except for the individual measurement teams, the other is the pattern I;

Mode III: This mode is only valid for BBFF and BF measurement modes. After erecting the instrument, test the BB (for example: Point ZQC03), then measure the intermediate points (such as: ZJD11, ZJD12 ...), and then test the FF (e.g. point 1) and finally move the station. That is, bb-Middle point-ff, or B-intermediate point-F, then move station.


bb-Middle Point-ff

The difference between mode I and Mode III, according to their own measurement mode to choose, if you do not know how to choose, just follow the pattern I can. 2.5 Error Record quantity setting

This setting determines the ratio of the amount of weight measured in the data to the total number of stations, if not specifically required, the default setting.


Default settings, you can adjust

2.6 Time Property settings

Measurement time: So the idea is the start time of the day and the time of each reading, when the transfer station. Timestamp (the last digit of the time), each instrument fixed, different instruments may be different, 1 is more common.
Break time: For cross-day measurements (more than 10 or dozens of km leveling route) is more applicable. When prompted for a break, you can choose not to rest or rest.


Set the start time and other parameters

You can see the actual measurement start time and measurement spend time

2.7 Batch processing function (batch generation dat or goto GSI data)

Before opening the template, tick "batch simulation", that is, batch simulation, the generated DAT file is stored by default in the path of the template.
"Batch Dat2gsi" with the ability to convert multiple DAT files in the same folder into the corresponding GSI file in batches.
Batch, with the ability to convert multiple DAT files in the same folder into a hand book.


2.8 template Check (auto Add to point)

When the adjacent point height difference is greater than the "high difference between adjacent points", the software automatically adds the transition elevation to the large adjacent points of the high difference;
Distances are divided into approximate thresholds when the distance is greater than the distance between two points. Automatically adds a pivot point and ensures that the simulated data is an even station;
The Add to point check box is selected to automatically add a point of change.
Visual range floating is selected by default and automatically adjusts the distance of sight in the software open template. If unchecked, the software follows the distance between the front and rear line of sight and equal to the distance in the template.

2.9 Inverse adjustment function

The inverse adjustment function can make the original data simulated by the software be consistent with the elevation data in the template after the adjustment. The software default is not to take the inverse adjustment, if you need this feature need to check this option. The inverse adjustment is divided into according to the measuring station adjustment and according to the ranging adjustment, needs according to own adjustment method to choose. It is recommended to select the station by test.

Operation: Before the simulation data check the inverse adjustment, according to "measuring station" or "ranging" to set the right, the middle point weight (default). (Middle point is fixed, no intermediate point can be ignored, this is only for the middle point of action, no intermediate point of the template software will ignore the middle point weight parameter). It is not clear that you can consult the author.

2.10 Level ruler reading limit setting

The software is automatically set according to the level level, but users can also set the parameters themselves.
The "line-of-sight height" can be set roughly, and the software will adjust the height above or below (simulating the height of the instrument in the actual measurement) to simulate the data.
"Ruler Selection", the default is 2m feet, you can set 3m feet.

2.11 Distance Limit setting

That is, the maximum distance between the front and back of the horizon measurement, distance difference limit, the total distance difference limit.
The "line of Sight" and "line of sight" check boxes are used for creep measurements.



Creep measurement effect, when the instrument does not move to measure a number of level points. The front distance of the previous station, the height and the next station after the distance, the height is equal.

2.12 Distance floating and multi-scale reading cross-difference settings

Set the front and rear distance difference range (This setting will be limited by the distance difference limit), the ruler surface reading, the minimum distance, the middle point of sight floating.



Sets the effect on the data.

2.13 Set file creation time, last modified time, last lookup time

Tip: The path is best not to include Chinese, otherwise the resulting file time attribute cannot be modified.


This dialog box appears when you save, making a single file time property setting. Time changes automatically when batch data is processed (the path cannot appear in Chinese).

Effect

3 Description of Toolbox functions 3.1 dat Turn dat

This feature can be converted to a new DAT based on existing DAT data. When using this function, the change in the elevation of the turn point is also small. It is recommended to modify the elevation of the transpose point in the Master DAT file, which is more appropriate to generate a new DAT after changing 5 or 6 centimeters. 3.2 Dat2gsi

Convert DAT files to the GSI format of lycra


The generated GSI format is set according to your own GSI data.

3.3 dat Turn Sokkia

Convert DAT files to sokkia CS1 format

3.4 gsi to Dat, GSI16 to gsi8,gsi8 turn GSI16



GSI8 data

GSI16 data

3.5 Remove Observation time, change observation time to °



Removal time

Time modified to degrees

3.6 Turn Section silly or Southern adjustment easy adjustment



in1 file

Pinchauipine Poor file

3.7 Generate level book

Action: Open the DAT file and click the "Go to Level Book" tool in the Toolbox to generate the Excel version of the record book.

3.8 Data Adjustment

Action: Open the DAT file and click the "Plane difference" tool in the toolbox to generate the final result of the adjustment.
Note: This function relative to the inverse adjustment is positive adjustment, select the right way after selecting the Adjustment tool in the Toolbox.


Adjustment results

3.9 dat to Southern adjustment easy and middle latitude



Southern Level

Mid-latitude level

4. precautions 4.1 Workaround when warnings occur during simulation

When there is a ruler reading overrun (the same station multiple overrun) there are 2 solutions: 1) Adjust the data template, in this station to add the excessive elevation of the point, 2) observe the warning message, if the front ruler and the back ruler readings can be accepted (no negative or greater than the ruler maximum reading), you can choose to skip.

4.2 Intermediate Point ruler reading overrun

Due to the intermediate point method, it relies on the reading of the front-view ruler of the current station (or the reading of the ruler at the previous station) to calculate the RZ value to get the elevation of the middle point. Therefore, the intermediate point simulation when the overrun (negative or more than the ruler maximum reading) all have to re-simulate (or selectively ignore).
There are two solutions:
1) Increase the point transfer elevation before and after the middle point, 2) place the middle point elevation in a group similar to each other. If the high difference will lead to some of the intermediate point simulation is appropriate, some will appear overrun.



Template making essentials with intermediate points

5. Service Support and FAQs 5.1 Technical Support

Please contact the author qq:3339745885 or join the Engineering Monitoring Technology Exchange Group to obtain the new software information, group number:452847739.

5.2 Software inexplicable disappearance reason

Proper safekeeping of legitimate software and registration code, because the software may be anti-virus software (360) deleted by mistake, you can recover the software from the anti-virus software.


Recover software in quarantine file, similar to other anti-virus software.

5.3 Double-click software does not start

If the double-click fails to start after installing as required, please follow the steps below to set it up:


Right-click Compatibility troubleshooter




After these three steps, the software can be used normally.

5.4 Software Exceptions



There are many reasons for this error (data is not standard, template is not appropriate, etc.), contact the author for advice to get the answer.

6. Software Dog version

With dog version of the software, can be used to plug the dog, not by the computer and the number of system bits (32 or 64-bit system) limited, flexible use. Support Win7, Win8, WIN10, XP system, software dog-free drive Plug and use.


Super Dog Real picture

6.1 Super Dog Software Installation

Contact the author for the software installation package. Select the x86 or x64 version of the software installation package based on the number of system bits.
32-bit system, you can open the x86 simulation software after installing the Vcredist_x86.exe in the x86 folder first.
64-bit system, you can open the x64 simulation software after installing the Vcredist_x64.exe in the x64 folder first. 7. Disclaimer

The author tries his best to make the software perfect, accurate and useful, but cannot guarantee its perfection. Once the author finds an error or omission, he will try to correct it as soon as possible in subsequent versions of the product. In order to serve users better, the following statement is made: any legal issues arising from the use of the software to simulate data are unrelated to the author of the software. In the process of using the software, the author by default you have understood the software all the functions, voluntarily use the software processing data. The user keeps the software and the corresponding registration code properly, and if it loses, the software author will try to help you find it. If the software prompts the hardware information and the registration of hardware information, the author default computer replacement, will no longer be responsible for helping to retrieve and upgrade. The efforts and help of the author are all out of good intentions, but not obligations. If the author is busy and has no time to help you out, don't whine about it. Be sure to notify the author before you redo the system. If the author is not notified, the redo system causes damage to the software the author is unsure that it will be recoverable. Computer replacement Hardware The default is to replace the computer, no longer enjoy software services. 8. Report software Download

Welcome to download Use mapping Butcher report software.
http://blog.csdn.net/wokaowokaowokao12345/article/details/76877219

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.