Troubleshooting RTX Development issues: Retrieving components with the CLSID {79210e58-99eb-45d0-8890-763efeaa143f} in a COM class factory failed because of the following error: 80040154.

Source: Internet
Author: User


Retrieving a component with a CLSID of {79210e58-99eb-45d0-8890-763efeaa143f} in a COM class factory failed because the following error occurred: 80040154.


Workaround:

1. If you are developing an environment that does not have the RTX server installed, register the associated DLL you called. Do not know how to register a DLL, into Baidu to check registered DLL

2. If you have a RTX server installed in your development environment, and your system is 64-bit. Then, in the project attribute, the build-> target platform is changed to X86


Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.